TSC201 is a compact current sensor with a 1-Wire interface and an input range up to 10 A, designed for AC and DC current monitoring. Its range allows direct measurement of low currents or connection to current transformers (CTs) with 10 A secondary output for accurate indirect monitoring of higher currents.
- 1-Wire protocol current transmitter
- Current measurement range: 0,1...10 A (AC / DC)
- Measuring accuracy: ± 1 %
- Resolution: 0,01 A
- Galvanic isolation between the current circuit and 1-Wire bus
- Power supply: 4,0…5,5 V
- Excellent long-term stability
- Warranty: 3 years
- Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
- Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
- Relay output: 2 units
- Communication interface: none / RS-232 / RS-485 / USB / CANopen
- Invertible analogue output (10...0 V, 20...0 mA)
- Fast and easy parameter configuration via USB
- Optional tare function (scaling to zero)
- Supply: 220 VAC / 24 VAC/DC
- Operating temperature: 0...50 °C
- Protection class: IP60 (front)
- Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
- Temperature input: none / Pt100 / Pt1000 / thermocouple
- Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
- Relay output: 3 units
- Communication interface: none / RS-232 / RS-485 / USB / CANopen
- Invertible analogue output (10...0 V, 20...0 mA)
- Fast and easy parameter configuration via USB
- Optional tare function (scaling to zero)
- Supply: 220 VAC / 24 VAC/DC
- Operating temperature: 0...50 °C
- Protection class: IP60 (front)
- Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
- Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
- Relay output: 4 units
- Communication interface: none / RS-232 / RS-485 / USB / CANopen
- Invertible analogue output (10...0 V, 20...0 mA)
- Fast and easy parameter configuration via USB
- Optional tare function (scaling to zero)
- Supply: 220 VAC / 24 VAC/DC
- Operating temperature: 0...50 °C
- Protection class: IP60 (front)
- Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
- Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
- Output: Modbus RTU, RS-485
- Reads data from 68 individual temperature cables and spears
- Supply: 230 VAC / 115 VAC
- Protection class: IP66
- Certificates: IECEx, ATEX
- Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
- Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
- Operating temperature: -20...+50 °C
- Protection class: IP66
- Certificates: IECEx, ATEX
- Enables the PC to be connected to HART interface, i.e. to configure a device
- Active operation: current loop is supplied
- Passive operation: used in an existing current loop
- Included HART-Tool software
- Supply: from USB
- Galvanic isolation between USB and HART
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply
- Configurable by the software DEV9K
- Galvanic isolation on all the ways (1500 VAC)
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
- Configurable by the software DEV9K
- Capable to connect the sensors to the analog inputs
- Galvanic isolation on all the ways (1500 VAC)
The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.
- Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
- Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
- Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
- Configuration the parameters via the WEB server
- RS232 port for RTS/CTS signals
- Hardware Watchdog, Heartbeat
- Electrostatic protection 15 / 8 kV
- Power supply: 5…36 V dc
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
- In PD24 converter are used 2 interfaces (USB, RS232) - galvanically isolated
- USB interface (type A) – destined for the device communication with the computer
- RS-232 interface - destined for the communication with devices from the object side
- PD24 is programmer of LUMEL products to configure settings using eCon software
- Compliance with the standard USB 1.1 and USB 2.0
- Data transmission rate up to 115.2 kbps
- Support virtual serial port (COM)
- Device supplied from USB port and from the RS-232 (TTL) side
- Set includes 1,5 m data transmission cable with RJ12 plugs to configure LUMEL products
- External dimension: 62 x 25 x 20 mm
- In PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated
- USB interface (type A) – destined for the device communication with the computer
- RS-485 interface - destined for the communication with devices from the object side
- Compliance with the standard USB 1.1 and USB 2.0
- Data transmission rate up to 115.2 kbps
- Support virtual serial port (COM)
- Bi-directional data transmission (half duplex)
- Device supplied from USB port
- External dimension: 76 x 25 x 20mm
- Converter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols
- MA series converters reads Wired M-Bus meters and transmit the data wirelessly using the Wireless M-Bus protocol
- Reads data from up to 500 devices
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: T1
- AES-128 encryption mode 5, profile A
- Automatically search wired meters and sends data
- Two internal antennas or one external antenna
- Power supply: 100…240 VAC
- Protection class: IP67
- G2-P pulse counter converts wired consumption meter into a wireless meter
- Types of devices: water, electricity, HCA, room sensor devices, etc.
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: configurable C, T, or S
- AES-128 encryption mode 5, profile A
- Value format: 0,001...10000 / pulse (configurable). Unconverted dimensionless value
- The total number of pulses is sent periodically
- It is possible to count pulses from two devices simultaneously
- Pulses from the electricity meter LEDs can also be counted using an optical probe (only one optical probe can be mounted)
- Transmission interval: configurable 60 s…1 hour
- Tamper protection
- Operating temperature: -30…+85 °C none condensing (recommended +5…+50 °C)
- Power supply: AA battery 3.6 V Li-SOCI2
- Battery lifetime up to 14 years, depends on configuration and operating temperature
Converter PD8 is designed for data transfer from devices with RS-485 port to Ethernet network. The device comes in two versions. First version is used with network service Real Port. In this case, the Master role is taken by PC with installed software, creating a parallel port. Software (i.e. Lumel Energy) ensures data transfer between devices with RS-485 port and one PC.
Second version (parallel bridge with UDP protocol) enables the sextension of data transfer system using additional PD8 converters and local Ethernet network. Variant with two converters or one with many (max. 65) converts is available.
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
- PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
- This enables to increase device number in the system and extend its range
2-channel binary input converter SM3 with RS-485/232 interface. Modbus RTU and ASCII.
8 binary output converter SM4 with RS-485/232 interface. Modbus RTU and ASCII.
8-channel binary input converter SM5 with RS-485/232 interface. Modbus RTU and ASCII.