Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.

 

Technical specifications

  • One or more level control
  • Switch output 2A, 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)

Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.

 

Technical specifications

  • One or more level control
  • Switch outputs: switching + NO 2 A / 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • One or more level control
  • Switch outputs: switching + 3 x NO 2 A / 250 VAC
  • Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • One or two level control
  • Switch outputs – switching + 5 x NO, 2A / 250 VAC
  • Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – filling, draining, dry flow, overflow, two/three pump control and others
  • Valve or gate control
  • Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
  • Mounted on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC

Counter ALC77-C for linear and rotary encoders (up/down).

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs + RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-T for linear and rotary encoders (for tachometers).

 

Technical specifications

  • 5 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-B for linear and rotary encoders (batch).

 

Technical specifications

  • 10 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC94UNI for linear and rotary encoders (up/down), universal.

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input
  • 6-digit LED screen
  • Range -99999...999999
  • 2 programmable set points (SPs)
  • 2 switch outputs OR RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 96 x 48 mm
  • Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
  • TR-040 (external setting): 0...40 °C
  • TR-040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Relay
  • Switching capacity: 24...250 VAC (16 A)
  • Ambient temperature: -35...65 °C
  • Protection class: IP65
  • Modern, simple and user-friendly service
  • Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
  • FTP server (available in controller versions with Ethernet interface)
  • Selection of PID parameters for any unit
  • For easy programming and devices configuration, LUMEL offers one common LPCon software
  • Parameter logging on SD card
  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming
  • Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
  • Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
  • Universal input for RTDs, thermocouples and analog signals
  • Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
  • The controller has three alarms, which can be assigned to each output
  • The output signals are galvanic isolated from the input signals and power supply
  • Selection of PID parameters for any unit, or auto-tuning
  • Protection class from frontal side: IP30, from terminal side: IP20