This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...10000 ppm
  • Operating temperature: -30...80 °C
  • Cable length: 1 / 2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Duct mount
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included

Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:

  • Periodic measurement of solid state particle concentration in stationary sources of emission
  • Solid state particle concentration measurement in gasses
  • Testing of dust removal equipment
  • Gas flow rate measurement
  • Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
  • Dioxins, furans, PAH, mercury concentration measurement
  • Heavy meal, HCL, HF concentration measurement
  • Oxygen concentration measuring in air and inert gas mixtures
  • Specially developed for use in composting plants
  • Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
  • Value indicator of measured oxygen concentration
  • Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
  • Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
  • Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
  • Material of protective tube: Stainless steel 1.4301
  • Housing ambient temperature: -10…+50 °C
  • Probe ambient temperature: -10…+100 °C
  • Protection class of housing electronic: IP65
  • Protection class of probe: IP40
  • Rechargeable battery with indication of voltage
  • It is possible to connect the sensor to a stationary data processing system
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications Sensor:  NDIR, 2 Measuring range: 0 ... 1000 ppm ..
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists. ..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists.          &n..
  • Measurement object: concentration of particulate matter (PM) in the air PM1.0, PM2.5 or PM10
  • Measurement range: 0…1000 µg/m3
  • Resolution: 1 µg/m3
  • Accuracy: ± 10 %
  • Measured data is sent wirelessly to Aranet Pro base station* and if needed to Aranet cloud*
  • Signal line of sight range: up to 3 km
  • Data transmission interval: 1, 2, 5 or 10 minutes
  • Protection: IP42
  • Operating temperature and humidity: -10…+60 °C; 0…95 % RH
  • Power supply: 12…24 VDC

The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.

Loading...