  • Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
  • Reliable self-monitoring: Integrated watchdog
  • Precise signal: 4–20 mA (2–10 V) output for easy system integration
  • Stable long-life optical NDIR gas sensor
    Range 0...10 000/50 000 ppm CO2
    Resolution 1/100 ppm for 10K/50K range CO2​
    Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
    Remote probe option

  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
  • Stable long-life electrochemical gas sensor
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 35 ppm CO
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 125 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • Visual and acoustic alarms
  • Long-life electrochemical cell
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range 0....200 ppm CO
  • Resolution 1 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • UART digital interface
  • Visual and acoustic alarms
  • Magnetic key switching
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
  • Communication: RS-485 interface for stable and secure system networking
  • Precise Detection: High accuracy thanks to digital signal processing
  • Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
  • Robust Design: Reliable with IP65 even under extreme conditions
  • CO2 concentration measurement range: 0...10 000 / 50 000 ppm
  • External sensor cable length 1 / 2 / 4 m
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 10 s...24 h
  • Calibration certificate included
  • LED, acoustic alarms
  • LCD screen
  • Data can be transferred to PC via USB-C interface
  • Operating temperature: -20...+60 °C
  • Supply: battery
  • Protection class: IP54
  • Warranty: 3 years
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...10000 ppm
  • Operating temperature: -30...80 °C
  • Cable length: 1 / 2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Duct mount
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
  • Versatile alarm function: Alarm and fault relays (30 V)
  • Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for reliable communication
  • Flexible: Connection of up to 3 sensors (2 digital)

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
  • Flexible control: 3 relays (SPDT, potential-free, 250 V)
  • Intelligent Communication: RS-485 interface with DGC and Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
  • Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
  • Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
  • Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
  • Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensor
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Universal datalogger with 3 hardware MiniDIN inputs for connecting temperature and humidity probes and 1 for external CO2 sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • External CO2 sensor, 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Temperature measurement range: -20…+60 °C
  • Humidity measuring range: 0…95 % RH
  • Dew point measuring range: -60…+60 °C
  • CO2 measuring range: 0…5000 ppm
  • Atmospheric pressure measuring range: 700…1100 hPa
  • Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
  • Measured values can be sent to the internet storage COMET Cloud or COMET Database
  • Communication protocols: HTTP(S), SMTP, Modbus TCP, SNMP (v1, v2c, v3), HTTP POST, HTTP GET (JSON, XML)
  • Alarm signalization: e-mail, acoustic, LED, SMS - additional order
  • Measuring interval: 1 s
  • Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
  • Calibration certificate of manufacturer included
  • Operating temperature: -30…+60 °C
  • Supply: 5,0…5,4 VDC USB-C connector
  • Protection class: IP30

Sensor SKU: 5906660327868 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Carbon dioxide (CO2) measurement range: 400…5000 ppm, accuracy: +/- (40 ppm + 5 % of reading)
  • Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection

Sensor measures carbon dioxide (CO2) concentration, temperature, and atmospheric pressure. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • CO2 measurements:
    • Range: 0…9999 ppm
    • Resolution: 1 ppm
    • Accuracy: ± (30 ppm + 3 % of reading)
  • Atmospheric pressure measurements:
    • Range: 300…1100 hPa
    • Resolution: 1 hPa
    • Accuracy: +3 hPa / -2 hPa
  • Temperature measurements:
    • Range: 0…50 °C
    • Resolution: 0,1 °C
    • Accuracy: ± 0.3 °C
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 8 years
  • Operating temperature: -40…60 °C
  • Protection class: IP67
  • CO2 concentration measurement range: 0...10 000 ppm
  • Output: 4...20 mA
  • Programmable
  • External probe cable length: 1 / 2 / 4 m
  • LCD display
  • Calibration certificate included
  • Ambient temperature: -30...+80 °C
  • Supply: 9...30 VDC
  • Protection class: IP65
  • Warranty: 3 years
  • NDIR gas sensor
  • Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
  • Resolution: 0.01 % vol.
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -25…+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical (CO) and optical NDIR (CO2) gas sensors
  • Range: 0...100 ppm CO, 0...10000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Electrochemical gas sensors
  • Range: 0...100 ppm CO, 0...20 ppm NO2
  • Resolution: 1 ppm CO, 0,1 NO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
  • Free software for configuration and data visualization
  • Bluetooth communication for smartphones and tablets (Android and IOS)
  • Safety lock magnetic mounting with inviolability system holder (accessories)
  • Compatible with food industry environment
  • Up to 4 recordable parameters simultaneously
  • Optional calibration certificate
  • To measure carbon dioxide in air and neutral gases range 0…5000 ppm
  • Configuration with switches or software: measuring ranges, outputs settings
  • Optional with display or without display
  • Ambient and duct models. Duct model available only without display
  • To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
  • Configuration with keypad or software: measuring ranges, units, outputs settings
  • Optional with display or without display
  • Galvanic isolation all the ways
  • On request range increase up to 0...20 000 ppm
Loading...