  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Power factor controller for reactive power compensation
  • Measures 73 power network parameters (40 visible on screen, all via Modbus RTU)
  • Relay outputs: 4 / 6 / 8
  • Programmable switch in time, switch off time and discharge time
  • Alarm message and relay output
  • Optional digital output: Modbus RTU (RS-485)
  • Optional real time clock (RTC)
  • LCD screen
  • Operating temperature: -10...+60 °C
  • Protection class (front): IP54
  • Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
  • Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
  • Measuring class A or A / S
  • Support the IEC 60870-5-104 communication protocol (new - option)
  • Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
  • Monitoring up to 6 additional energy meters with pulse output
  • Recording of measurements before and after events (dips & swells)
  • Configurable archives of logged values and events
  • SD card support (up to 32 GB)
  • Webserver function, FTP server, DHCP client
  • Outputs: relays, binary, analog
  • Binary inputs
  • E-mail alarms
  • Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
  • Color touchscreen: LCD TFT 5.6“
  • Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
  • IP65 protection class for front side
  • Real time clock (RTC) synchronization with NPT time server
  • Time synchronization via external GPS module - STR  receiver (new - option)

Reactive power controller RMB-10S. The device is designed for reactive power compensation battery control. Version with 6 switch outputs is available.

Wireless Aranet radation sensor is portable device for measuring levels of ionizing radiation (γ, β) and x-rays. This sensor ensures comprehensive ionizing radiation monitoring by measuring both the total dose and dose rate. Perfect for home use to ensure the safety of your family and yourself! Ideal for travelers, explorers, and individuals who are frequently near radiation sources.

  • Detected types of radiation: γ, β, x-rays
  • Ionizing radiation dose measurement range: 0…1000 µSv/h or 0…100 mrem/h
  • Measures radiation dose rate (µSv/h / mrem/h) and total dose (mSv / rem)
  • Dose accumulation time limit: 2 years
  • Bluetooth Low Energy connection with smartphone (Android or iOS) using Aranet Home mobile app
  • Supply: 2 x AA batteries
  • Battery lifetime (20 °C): up to 4 years (see datasheet)
  • Measuring intervals: 1, 2, 5, 10 min. (If the radiation threshold is surpassed, the device automatically switches to a 1-minute interval)
  • Audial ionizing radiation detection feature (pulse counter buzzer)
  • E-Ink display for longer battery life
  • Operating temperature: 0...+50 °C
  • Protection class: IP20
  • Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
  • 54 electrical network quality parameters
  • Analysis of voltage and current harmonics (up to the 51-st)
  • Color touchscreen: LCD TFT 3.5“, 320 x 240
  • 2 configurable alarm outputs
  • Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
  • Digital output: RS-485 (MODBUS)
  • Ethernet / Profinet 2.2
  • Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
  • Battery backup RTC
  • Dimensions: 96 x 96 x 77 mm

Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.

The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.

  • Two-color LED display
  • Backlit units of all measured quantities
  • Configurable analog and alarm outputs
  • Digital RS-485 interface, MODBUS
  • Archiving data in the internal memory file system memory 8 GB
  • Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
  • services: www server, ftp server, DHCP client
  • PAR measurement range: 0...4000 μmol/s/m2 PPFD
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 5 years
  • Operating temperature: -20...55 °C
  • Protection class: IP68
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm

Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).

  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Meter to measurements electric quality parameters in 3 phase systems
  • Programmable display pages
  • 3 programmable alarm outputs and 1 pulse output
  • Digital transmission to the master system through the RS-485 interface
  • USB for configuration by using free eCon software
Loading...