  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical gas sensor
  • Range: 0...10 ppm Cl2
  • Resolution: 0,1 ppm Cl2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC (default), 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Standard calibration: methane
  • Range: 0...100 % LEL
  • Resolution: 0,1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Compact sensor VA 525 for measuring compressed air or nitrogen inline.

  • 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
  • Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
  • Pressure range up to 16 bar
  • Temperature range up to 60°C
  • For speeds up to 224 Nm/s
  • Integrated display to show the measured values
  • Available from 1/4" to 2''
  • Settings adjustable via the keys of the display
  • Main counter can be reset via the display
  •  
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 2 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
  • Relay output: 4 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
Microprocessor controller INDU-30 with RS-485 interface for temperature and humidity control in food and other industries. The device is designed for temperature and humidity control in food and other industries (drying, climate chambers, etc.). Humidity measurement is done via psychorometer method. Two programmable inputs are used for temperature sensor connection and one for standard signal 0/4...20 mA. Version for work with thermocouples is also available. The device can log measured values in set time intervals. Data is transferred via RS-485 interface. Control starts in set t..
Microprocessor controller INDU-50 with RS-485 interface for temperature control in thermal processing devices in food industry. The device is intended to be us in boiling pots, vaporizers, grills, climate chambers and so on. Measured values can be logged into the internal memory. Data is transferred via RS-485 interface. Real time clock. Control starts in set time or after set delay. Technical specifications Input: 2 analogue inputs PT-100 (PT-500, PT1000) channel 1: temperature – ‘dry’ thermometer channel 3: temperature – ‘we..
  • Two pressure transmitters in one device
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Option: DPT-DUAL-MOD-AHU – with air flow transmitter
  • Output: Modbus RTU
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Input: 2 x  0...10 V, NTC10k, Pt1000, Ni1000, binary
  • Output: Modbus RTU
  • Temperature compensation in range of 0...50 °C
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54

Differential pressure transmitter with Modbus interface DPT-MOD-2000, DPT-MOD-3000 and DPT-MOD-5000 for usage in air and non-aggressive gasses.

  • PID controller
  • Pressure measurement range: 0...2500 Pa
  • Modbus RTU communication
  • Control output: 0...10 V
  • External input: 0...10 V / thermistor / binary
  • LCD display
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • RS-485 (Modbus) protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Humidity temperature range: 5...95 %RH
  • Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
  • Resolution: 12 bits for temperature and humidity
  • Long-term stability
  • Warranty: 3 years
  • RS-485 protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Humidity temperature range: 5...95 %RH
  • Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
  • Resolution: 14 bits for temperature, 12 bits for humidity
  • Long-term stability
  • Warranty: 3 years
  • Connection: RJ-45
  • Electrochemical gas sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution: 0,1 / 1 / 1 ppm C2H4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical gas sensor
  • Range: 0...20 / 0...100 ppm C2H4O
  • Resolution: 0,1 / 1 / 5 ppm C2H4O
  • Analog output: 2 x 4...20 mA / 0a...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Default calibration: methane CH4
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL
  • Resolution: 0,1 / 1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL CH4
  • Resolution: 0,1 / 1 % LEL CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...25 % vol O2
  • Resolution: 0,01 % vol O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

Thermal mass flow sensor for compressed air and gases VA 500

  • 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
  • Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
  • Optional: Bi-directional measurement
  • Pressure tight up to 50 bar
  • Temperature range up to 110 °C
  • Protection class IP65
  • Suitable for gas velocities up to 224 Nm/s
  • Integrated display for showing the measured values
  • Can be used from 1/2" up to 40", larger diameters on request
  • Easy installation under pressure
  • Settings can be changed via the display
  • Main counter reading can be reset via the display
  • Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
  • Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
  • Output: Modbus RTU, RS-485
  • Reads data from 68 individual temperature cables and spears
  • Supply: 230 VAC / 115 VAC
  • Protection class: IP66
  • Certificates: IECEx, ATEX

SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air

  • Changeable communication parameters
  • Non-volatile memory for all settings
  • Operating temperature range: -20…60°C
    • Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
    • Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
    • Resolution: 0.1 °C
  • Operating relative humidity range: 10…90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0.1 % RH
  • Ingress protection: IP20
  • Operating voltage range: 4.5…26 VDC
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0...10 V / 2...10 V / 4...20 mA
  • Option: LCD display
  • Option: relay output
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP20
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0/2...5/10 VDC
  • Option: LCD display
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Electrochemical gas sensor
  • Range: 0...100 / 0...2000 ppm H2S
  • Resolution: 0,1 / 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Universal input for measuring temperature, resistance and standard signal
  • 4 alarm outputs with signaling on LED diodes
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Analog signal output: 0/4...20 mA or 0...10 V
  • Two-line LCD display
  • Mathematical functions for converting the measured value
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Input: 0...20 mA, 4...20 mA, 0...1 V, 0...10 V
  • Display: 4 digits (value range: -1999...4000)
  • Measurement unit can be displayed
  • Option: 2 x relay output for control and alarm
  • Option: sensor supply output
  • Option: RS-485 Modbus RTU interface
  • Manual calibration
  • Stores maximum and minimum measurement values
  • Operating temperature: 0...50 °C
  • Supply: 230/110 VAC / 12/24 VAC / 9...30 VDC / 7...24 VAC
  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
  • 4 alarm outputs with signaling on led diodes, working in 7 different modes
  • Analog outputs: 0/4...20 mA or 0...10 V
  • Digital output: RS-485 / MODBUS RTU
  • Two-line LCD display
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

TSM400-4-CP is a multi parameters sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures barometric pressure and CO2 concentration.. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.

  • Changeable bitrate and other communication parameters
  • Non-volatile memory for all setting
  • CO2 measurements range: 400…5000 ppm
    • Accuracy: ± (40 ppm + 5 %)
    • Resolution: 1 ppm
    • Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
  • Pressure measurements range: 10…1200 hPa
    • Accuracy (min): ±1.5 (25°C, 750 hPa)
    • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
    • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC
  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC