Ничего не куплено!
- Датчик температуры AUREGIS ТJ-1 с соединительным кабелем
- Предназначен для измерения температуры в диапазоне -50°C до 400°C
- Возможны исполнения по требованиям заказчика
- Тип сенсора: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- Input: 4x external Pt100 sensors
- Measuring range: -200…+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- Resolution: 0,1 °C
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: adjustable 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+70 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP20
- Warranty: 3 years
- Inputs: 4x external sensors + 1x internal temperature sensor
- 3x Thermocouple type B, J, N, S, T external temperature sensor
- Measuring range: according to the connected thermocouple
- Accuracy: ± 0,4 °C
- Resolution: 0,1 °C
- 1x PT1000 external temperature sensor
- Measurement range: -200...+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- Resolution: 0,1°C
- Internal temperature sensor
- Measuring range: -30…+70 °C
- Accuracy: ± 0,4 °C
- Resolution: 0,1 °C
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: adjustable 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+70 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP20
- Warranty: 3 years
TJ-1V sensor is convenient for installation on pipes with staples. For HVAC systems.
- Measurement range: -30...+105 °C
- Sensor type: PT100, PT1000, PTC, NTC, Ni1000, TC K
- Sensor measurement material: brass
- Cable of two or three wires with PVC isolation. Cable length: on request
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-4 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-S is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.
Various cable lengths are available.
- Sensor type: PT100, PT1000, NTC, Thermocouples K, J
- Measuring range: -50…+400 °C
- Operating temperature:
- -30...+70 °C (PVC isolation)
- -50...+180 °C (Silicone isolation)
- -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
- -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
- Cable and connection: 2, 3, 4 wire
- Sensor tube:
- Material: Stainless steel 316 (1.4401)
- Diameter: Ø4 mm
- Length: 120 mm
- Input: 4x external temperature probes (Pt1000)
- Temperature measurement range: -90…+260 °C
- Accuracy: 0,2 in the range -90…+100
- Resolution: 0,1 °C
- Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
- Measured values can be sent to the internet storage COMET Cloud or COMET Database
- Communication protocols: HTTP(S), SMTP, Modbus TCP, HTTP POST, HTTP GET (JSON, XML)
- Alarm signalization: e-mail, acoustic, LED, SMS - additional order
- Measuring interval: 1 s
- Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
- Calibration certificate of manufacturer included
- Operating temperature: -30…+60 °C
- Supply: 5,0…5,4 VDC USB-C connector
- Protection class: IP30
- Inputs: 2x Pt1000 and 2 x binary input (sensors are not included)
- Binary voltage input: low level < 0,4 V; high level: > 2 V; voltage applicable 0…30 V DC
- Binary voltage-free input: switched-on state < 10 kOhm; switched-off state > 300 kOhm
- Binary input IS NOT suitable for catching the „voltage applied / not applied” states
- Temperature measurement range: -200...+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate of manufacturer included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: battery SONY Li-ion 5200mAh
- Protection class: IP20
- Warranty: 3 years
- Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
- PID or ON/OFF control
- Automatic selection of PID parameters
- One relay output and one alarm relay
- Manual control mode
- One binary input
- Operating temperature: 0...50 °C
- Supply: 230 VAC
- Protection class: front IP65, back IP20