The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.
- Temperature range: -30...+70°C
- Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
- Resolution: 0.1
- Humidity range: 0...100 % RH
- Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
- Memory: 32000 (16000 temperature and 16000 humidity)
- USB interface for data download
- Logging interval: 15 s...10000 min
- Supply: 2xAA battery, 3.6 V
- Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
- Size: 45 x 100 x 19 mm
The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.
Technical Specifications
- Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
- Zones: Suitable for Zones 1, 2, 21, and 22
- T-Class: T6, T5, T4, T3, T2, T1
- IP Rating: IP65 for dust and water resistance
- Operating Temperature: 65°C (energized) / 85°C (de-energized)
- Ambient Temperature: -20°C to +55°C
- Power Output: Self-limiting heating cable, adjustable to drum size
- Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
- Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
- Available Sizes: For 200/220L drums
- Applications: Frost protection, temperature maintenance, chemical processing
- Designed to be weld-in into pipelines and boilers
- Instrument standard threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: solid or welded
- Available materials: 1.4301 (AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Standard instrument threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: welded or solid (flange welded)
- Available materials: 1.4301(AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
Solid drilled threaded thermowells, protective cases:
- Protect and extend the lifetime of temperature sensors and thermometers in processing applications
- Facilitate the replacement of sensors
- Allow sensor maintenance without process interruption
Thermowells protect and extend the lifetime of temperature sensors and thermometers in processing applications where the sensors are not mechanically or chemically compatible with the process environment. Moreover, thermowells facilitate the replacement of sensors and allow sensor maintenance without process interruption.
- Module is designed to protect battery if it discharges below 10,5 V mark, disconnecting it from load
- Battery is automatically reconnected to load if its voltage rises
- Suitable for work with heaters, lighting, travel refrigerators, etc.
- Operating voltage: 12 V ZBxx, 24 V ZBxx-24V, 48 V ZB-48V
- Maximal current: 40 A ZB40, 80 A ZB80, 140 A ZB140
- Operating temperature: -20...50 °C
- Dimensions: 65 x 89 x 70 mm
- For methane, butane, propane and hydrogen
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarms at 20 / 50 % LEL
- For methane, butane, propane and hydrogen
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- For methane, LPG, hydrogen and acetylene
- Can be calibrated for methane, butane, propane, acetylene and hydrogen
- Stable long-life metal-oxide gas sensor
- Range: 0...100 % LEL
- Resolution: 0,1 % LEL
- Outputs 2 x relays with switch-over contacts
- Default alarms set-points 10 / 25 % LEL
- UART digital interface
- Alarms: blinking LED, 85 dB buzzer
- Metal-oxide gas sensor
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Standard calibration: methane
- Range: 0...100 % LEL
- Resolution: 0,1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
- Temperature range: -30...70 °C
- Accuracy: ±0,5 °C (-10 °C...40 °C) / ± 1 °C
- Display: LCD
- Battery work time: 2 years
- Battery type: 1/2 AA (3,6 V)
- Dimensions: 45x100x19 mm
- Protection class: IP65
- Weight: 85 g
- Holder is ordered separately
Gas cylinder heating jacket prevents frosting and ensures a constant flow rate for laboratory and industrial processes. Equipped with a digital thermostat, it is suitable for various gases and has a durable, lightweight design with quick-release buckles for easy attachment and transport.
- Digital thermostat with a heating range from 0 – 90ºC
- Durable, lightweight design with quick-release buckles
- Suitable for various gases, including SF6, Propane, Nitrogen, Oxygen, BCl3, WF6, and HF
- Silicone impregnated fabric
- Fiberglass insulation
- Teflon heating wire
- 3 meter power cable (no plug)
- Safety Thermostat
- IP40 Protection
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.
- Material of float: stainless steel AISI 316 SS
- Max. temperature: -30...+105 °C
- Switch rating: 50 VA
- Switching voltage: 230 AC / DC
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
System is designed to measure width of planar products on conveyor belt. System can be used as a separate module or integrated into production line for process control. It enables to compensate conveyor belt unevenness even if shaft imbalance to axle is present, not affecting measurement accuracy.
If there is no way to measure the product from both sides (i.e. on conveyor belt), one-sided system can be used. In this way the accuracy will depend on evenness of product movement.
Can be conducted without stopping the belt:
- Measure product width
- Detect product curvature
Additional functions:
- Count products
- Measure downtime
- Control processes which influence product width
System consists of following:
- Sensor Instruments high accuracy laser distance sensors
- PLC
- HMI or computer
SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7
SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area
The enLink Status-T transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- External sensor measurement range: -55…+125 °C
- Accuracy: ± 0.5 °C (-10…+85 °C)
- Up to two probes (cable length: 1 m, others on request)
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by alarm)
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Each sensor can be programmed individually for different alarm type: No alarming, High threshold alarm, Low threshold alarm, In band alarm, Out of band alarm
- Each alarm type has an individual alarm status message with the following parameters: Alarm status, Total number of alarm activations, Alarm duration
- Case IP40 protection (IP 67 on request)
- The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
- Long range and high sensitivity internal (or external mounted) antennas
- To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
- The gateway firmware can be upgraded remotely using MQTT
- B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
- Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
- Possible to activate 128 bit AES-key encryption
- Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
- IoT LTE M SIM card needed (acquired separately)
- Wide gap between the two parts of sensor
- Protection class: IP65
- Max switching voltage: 100 V
- Max switching current: 0,5 A
- Cable length: 0,45 m
- Warranty: 3 years
- Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
- It is a new generation, small size IR device for high temperature measurement
- Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
- That said, measurements can be done in various environments and from various distances
- Noncontact stationary infrared temperature meter CM for temperature measurement
- Range: -20...500 °C
- Outputs: 0...5V, or TC K / J type (chosen while ordering)
- Software “DataTemp Multidrop” for remote monitoring and configuration
- Noncontact infrared thermal meter (pyrometer) ENDURANCE
- for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
- Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
- Web server
- Wider area can be measured when used with SpotScan
- Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
- Range: -40...3000°C (in fixed ranges)
- Outputs: 0/4...20mA, RS485, mechanical switch
- Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
- Can be used in an explosive area
- Range: -18...2000 °C (in fixed ranges)
- Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
ORP electrode sensors (glass, epoxy body and submersible)
Applications:
Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
- at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line) ≤ 55 V
- at In, C2 (8/20 μs, line-PG) ≤ 500 V
- at C3, 1 kV/µs (line-line) ≤ 48 V
- at C3, 1 kV/µs (line-PG) ≤ 600 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
- For protecting low voltage equipment against lightning and surge damages
- For installation in conformity with the lightning protection zones concept at LPZ 0-1
- Designed according to IEC 61643-11:2011
Specifications:
- Category IEC / EN / VDE: class II+III / type 2+3 / C+D
- Max. continuous operating voltage Uc 275 V AC
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- Voltage protection level Up ≤ 1,5 kV
- Max. backup fuse 125 A
pH electrode sensors (glass, epoxy body and submersible)
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply
- Configurable by the software DEV9K
- Galvanic isolation on all the ways (1500 VAC)
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
- Configurable by the software DEV9K
- Capable to connect the sensors to the analog inputs
- Galvanic isolation on all the ways (1500 VAC)
- Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
- Fast and easy operation via Android app “Sensor Master Communicator SMC”
- Read out of sensor data
- Parametrization of switich points on NAx pressure switches
- Measuring range adjustment on submersible pressure transmitter ECL
- Reset pressure measurement instruments to factory settings
- Ambient temperature: 0...40 °C
- Supply: 5 V (USB)
- Communication: Bluetooth Low Energy
- Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
- Plinth or foundation for fixing the cabinet.
- PLC controller with a display that changes the backlight depending on operating mode.
- Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
- Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.
- IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
- Application: main distribution boards (MB)
- Power networks: TT, TN-S, TN-C
- Protection modes: L-N, N-PE
- Protective elements: MOV, MOV+GDT
- Enclosure: modular (replaceable module)
- Mechanical status indicator: green/red flag
- Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
- Temperature measurement range: -100…+300 °C
- Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
- Resolution: 0.01 °C
- Memory: 32 000 readings
- Power supply: battery 3.6V 1/2AA
- Operating temperature: -30…+70°C
- Protection class: IP65
- Wall mount available as optional accessory
- Temperature measurement range: -100…+300 °C
- Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
- Resolution: 0.01 °C
- Memory: 32 000 readings
- Power supply: battery 3.7V 1/2AA (Charging time: 1,5 h)
- Operating temperature: -30…+70°C
- Protection class: IP65
- Wall mount available as optional accessory
- Temperature sensor with penetration probe, “T” type handle and cable connection head
- Various sizes are available depending on customer requirements and drawings
- Sensor type: Pt100, Pt1000, K, J
- Accuracy class: A or B / cl. 1 or 2
- Measuring range: -30...180 °C or -30...260 °C on request
- Sensor’s tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø 6 / 8 / 10 mm
- Length: 100, 200, 500, 700, 1000 mm on request
- The total length of the sensor handle is 220 mm
- Connection head:
- Type: M, B (transducer on request)
- Protection class: IP65
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Versions according to PN-79/M-53857/05
- Threads for thermometer: metric M12x1.5, M14x1.5
- Lengths: according to customer's specification
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Bore diameters: Ø3.5 mm, Ø7 mm
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Optional designs per DIN 43772 ( form 4 )
- Other materials, threads and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
- Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
- Dimension tolerance according to DIN ISO 2768
- Protection tube coated by layer of CrC to increase abrasion resistance
- Protection tube coated by teflon® PTFE to increase corrosion resistance
- Other materials, threads, flanges and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions