The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes
- 52 programs, holiday mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 1 CO
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
- Stable long-life electrochemical gas sensor
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 35 ppm CO
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 125 ppm CO
- Outputs 2 x relays with switch-over contacts
- Visual and acoustic alarms
- Long-life electrochemical cell
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Outputs 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range 0....200 ppm CO
- Resolution 1 ppm CO
- Outputs 2 x relays with switch-over contacts
- UART digital interface
- Visual and acoustic alarms
- Magnetic key switching
- Electrochemical gas sensor
- Range:
- -- 0…300 ppm CO
- -- 0...1000 ppm CO
- Resolution: 1 ppm CO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
- Communication: RS-485 interface for stable and secure system networking
- Precise Detection: High accuracy thanks to digital signal processing
- Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
- Robust Design: Reliable with IP65 even under extreme conditions
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
- Range: from 0....60 to 0...5 kPa
- Accuracy: ±2% (FS 20°C)
- Allowed overpressure: 20 kPa
- Operating temperature: -5...+60°C
Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 20…1500 Pa
- Operating temperature: -5… +60°C
Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 40…1500 Pa
- Operating temperature: -20… +60°C
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
The enLink Status-P transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 3 channels pulse counter (S0 standard) and monitor of state (open / closed)
- With the transmit on Change of State enabled the unit operates as a standard pulse counter and also transmits a message when the state of the input changes from closed to open or open to closed
- The pulse counts for each channel are written to memory every 5 – 10 minutes
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by change of state)
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
- Range: -250...2550 Pa
- Maximal overpressure: 30 kPa
- Accuracy: ±1,4 %
- Pressure and air flow measurements from air diffusers and valves
- Data can be uploaded on your computer for visualization and further analysis
- Over 700 programmed valve types
- Mediums: air and non-aggressive gases
- Operating temperature: -10... +50 °C
- Connection: ø 5 mm pressure hoses
- Can be used with Pitot tube
- 5 year warranty
- Included: calibration certificate, 2 x 2 m PVC hoses
- Input: Modbus RTU – RS-485
- Output: 4-channel SPST relay contacts
- Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
- Non-volatile memory to retain and restore relay states following power outages
- Watchdog functionality for communication loss
- Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.
- Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
- Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
- Tamper protection: device vandalism, masking and covering
- Real-time monitoring of student loitering via live video streaming
- No license subscription required for use
- The sensor independently performs all measurements and detections and sends alarms itself
- *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
- Event logging of alarms in the device
- Communication: LAN, WiFi
- Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
- Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
Multifunction astronomical digital clocks RDT-TPA2 are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise.
- 80 programs (astronomical and annual), holiday mode, random mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 2 CO (each channel can be assigned an individual program)
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
- Electrochemical gas sensor
- Range: 0...250 ppm NO
- Resolution: 1 ppm NO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 3 / 6 ppm NO2
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range:
- -- 0...20 ppm NO2
- -- 0...200 ppm NO2
- Resolution:
- -- 0,1 ppm NO2 for 20 ppm range
- -- 1 ppm NO2 for 200 ppm range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.
Traditional U-shaped with easily controlled zero point. For air and non-aggressive gasses.
- Range: -500...500 Pa
SV23 Sensor help customers monitor spaces where cameras cannot be deployed and get insight into environmental conditions that cameras cannot detect. From protecting school bathrooms against bullying and vaping to gathering real-time insight into air quality conditions like carbon dioxide levels.
- Measurement objects:
- Vape index – for vape smoke detection, range: 0…100
- PM2.5 - concentration of particulate matter, range: 0…10000 μg/m3
- TVOC index, range: 0…500
- Motion detection – FoV (field of view): 120 °
- Noise – range 20…120 dB
- CO2 (carbon dioxide) – range: 0…40000 ppm
- AQI (Air quality Index) - range: 0…500
- Temperature – range: -5…+45 °C
- Humidity – range: 0…95 % (non-condensing)
- Cloud Storage: up to 365 days
- Connectivity: RJ-45 cable connector for Network / PoE powering IEEE 802.3af
- Receive alerts for offline sensor and device tampering
- Operating temperature range: -5…+45 °C
Fluid manometer for air and non-aggressive gasses – high quality pressure meter for narrow temperature ranges.
- Range: 0…10 kPa
- For toluene, xylene, ethanol, etc.
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 3 ppm LEL
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 % / 50 % LEL
- Remote probe option
- For toluene, xylene and ethanol
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 relays with switch-over contacts
- Default alarm set-points 10 % / 25 % LEL
- Visual and acoustic alarms
- For toluene, xylene and ethanol
- Default calibration toluene
- Long-life metal-oxide sensor
- Range 0...100 % LEL (0...1 % vol) toluene
- Resolution 3 ppm toluene
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 % / 50 % LEL
- Acoustic alarm
- For toluene, xylene, ethanol, etc.
- Default calibration toluene
- Long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 3 ppm toluene
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- For toluene, xylene, ethanol and 2-propanol
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range: 0...100 % LEL or 0…500 ppm
- Resolution 0,1 % LEL or 1 ppm
- Outputs: 2 relays with switch-over contacts
- Acoustic and visual alarms
The TSF400-0 is a compact water-leak detector designed for early detection of water presence on floors, trays, or inside equipment enclosures. It operates from a wide 4.5–26 VDC supply and provides an N-channel open-drain output for direct connection to PLCs, controllers, alarm modules, or building-automation systems.
Applications:
- Leak detection in server rooms, UPS rooms and telecom shelters
- HVAC drip trays, cooling/condensation lines
- Under-floor and raised-floor monitoring
- Domestic and commercial flood-alert systems
Specifications:
- Operating temperature range: 0...50 °C
- Ingress protection: IP65
- Cable length: 3 m
Sensor SKU: 5905309601376 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Device monitor state of relays or reed switches (1 channel for input)
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327714 (IP30)
Sensor SKU: 5905309600713 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Device monitor state of relays or reed switches (1 channel for input)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Sensor's configuration can be changed remotely from the cloud or with a mobile application over Bluetooth Low Energy
- Operating temperature: -35…+70 °C
- Case IP30 protection (IP67 on request)
LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.
Collected data is processed and stored in the gateway, and can be accessed via a web browser.
- Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
- Individual alarm notifications based on specific sensors or contacts
- Alarm notifications via email and SMS
- Logging and review of errors and communication issues
- Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
- Dynamic data visualization in graph (curve) format via a web browser
- Data export in CSV and PNG formats
- Password-protected user interface
- No subscription required for the gateway or sensors
- Remote configuration of data transmission intervals for devices via a web browser
- Communication range from sensor to gateway:
- 15 km Outdoors (in plain sight)
- 50–200 meters indoors or up to 7–8 walls*
- LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power
- Electrochemical (CO) and optical NDIR (CO2) gas sensors
- Range: 0...100 ppm CO, 0...10000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Electrochemical gas sensors
- Range: 0...100 ppm CO, 0...20 ppm NO2
- Resolution: 1 ppm CO, 0,1 NO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Photo ionization detector
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: isobutylene
- Range: 0...40 / 0...200 ppm (isobutylene)
- Resolution: 1 / 1 ppb
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+65 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: toluene
- Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
- Resolution: 0,1 % LEL / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.
- Range: -100…1500 Pa
- Operating temperature: -40… +60°C
♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option
Micro-manometer HP (differential, liquid) HP5, HP10, HP15.