- Designed for direct or indirect measurement of 1-phase network parameters
- Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
- Direct measurements up to 63 A
- Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
- Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
- OLED display
- Programmable current and voltage transformer ratios
- Programmable via buttons or free eCon software (through USB)
- Size: 53 x 110 x 60 mm
- Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
- THD factor
- Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
- Digital output: RS-485 MODBUS (option)
- Protection class for front side: IP65
- Supply: 85...253 VDC/VAC
- Backlit LCD display
- Dimensions: 96 x 96 x 77 mm
Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).
Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).
- Portable analyzer NP40 is designed for power network quality parameter analysis
- Analyses voltage and current harmonics up to 51-st, THD
- Real-time waveform display (4 voltage / 4 current)
- Measurement of TRMS currents up to 3000 A (with standard sensor)
- Half cycle RMS measurement (voltage and current)
- Measurement in 1-phase and 3-phase systems (3- and 4-wire)
- Voltage, current, harmonics, power, energy and other parameter measurement
- Graphical representation of data in a waveform and vector diagram
- Record of events: dips, swells, overvoltages
- Built-in 8 GB memory card
- Ethernet interface for remote monitoring
- USB interface for data transfer
- Color 5,6” TFT display, 320 x 240 px
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
- Multimeter with backlit LCD screen (two shown values)
- Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
- Capacity measurement from 1 pF to 40 mF
- AC and DC voltage measurement from 100 μV to 1000 V
- AC and DC current measurement from 10 μA to 10 A
- Resistance measurement from 100 mΩ to 60 MΩ
- Frequency measurement from 10 Hz to 10 MHz
- Diode measurement and continuity testing
- Hold function
- Relative measurement
- Duty cycle (%) measurement
- Temperature measurement (K type thermocouple) from 0 to 1300 °C
- Peak value measurement
- Digital multimeter with data logging view function (up to 32000 readings)
- Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
- TRMS measurement
- Low input impedance
- Capacity measurement from 1 pF to 40 mF
- AC and DC voltage measurement up to 1000 V
- AC and DC current measurement up to 10 A
- Resistance measurement
- Frequency measurement
- Diode measurement and continuity testing
- Filtering
- Square wave signal generator
- Hold function, backlight, maximal and minimal value presentation
- External supply
- Duty cycle (%) measurement
- Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
- Automatic / manual range selection
- USB connectivity (optional)
- Digital multimeter for insulation resistance measurement
- Multimeter with backlit LCD screen
- AC and DC voltage measurement up to 1000 V
- AC and DC current measurement up to 300 mA
- Resistance measurement up to 30 mΩ
- Insulation resistance measurement up to 3 GΩ
- Capacitance measurement up to 30 μF
- Frequency measurement up to 100 kHz
- Fill factor measurement (%)
- Hold function
- Temperature measurement (Pt100 and Pt1000)
- Diode check
- Analog scale on screen
Frequency meters CA32, CA36, CA37, CA39, CA39L are designed for frequency measurement in electrical grid. Transducer signal is measured using magnetoelectric effect. Tropical version available.
- Frequency range: 45...55, 45...65, 48...52, 55...65, 360...440, 380...420 Hz
- Voltage range: 60,100, 110, 230, 240, 400, 415, 440, 500 ± 20%
- Accuracy class: 0,5
- Consumed power: =< 7 VA
- Protection class: IP52 or IP65
- Standards conformed: EN61000-6-2, EN-61000-6-4, EN-61010-1
- Temperature range: 5...23...40 °C