  • To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
  • Configuration with keypad or software: measuring ranges, units, outputs settings
  • Optional with display or without display
  • Galvanic isolation all the ways
  • On request range increase up to 0...20 000 ppm
  • The program is designed to represent and log measured values
  • Representation tools: bar graphs, graphs, numbers
  • Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
  • Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
  • Data logging: tables and/or graphs in PC memory
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems
  • Measurement distance: 0,5…2 m
  • Accuracy: ± 0,5 °C
  • Measurement speed: 0,7…2 m
  • Software: DERMALOG Fever Detection (PC required)
  • Interface: USB 3.0
  • SDK: .Net / C / C++ / (Java coming soon)
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable
  • The system is designed to monitor pressure and flow rate of medical gasses
  • Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
  • SCADA software enables the visualization of the process
  • Data is logged annd represented on the computer screen
  • Values can also be represented in graphs
  • The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
  • The data is gathered from various measuring devices and conveyed into a PLC
  • PLC and SCADA interface is MODBUS TCP
  • Manual and automatic control is available
  • Marameters can be changed via SCADA (IGSS) software
  • All data is logged