Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- Intelligent numerical signal processing with false reflection elimination
- Measuring range up to 8 m or up to 20 m
- Current output - 4...20 mA, HART communication
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapors
- Operating temperature: -30…+70 °C
- Protection class: IP68
- Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- FMCW antenna radar level gauge with a range of up to 20 m
- Teaching function to suppress false reflections
- Display of measured values on matrix OLED or LCD display
- Current output - 4...20 mA, HART communication
- Manual or remote adjustment
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapours or vacuum
- Operating temperature: -30…+70 °C
- CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
- Stainless steel design suitable for the food and pharmaceutical industries
- Output: 4...20 mA with two-way HART
- Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
- Arbitrary electrode length (up to 20 m)
- Display of measured values on matrix OLED or LCD display
- Power supply: 18…36 V DC
- Protection class: IP67
- Input: differential pressure
- Typical areas of use are chemical industry and process engineering
- Measurement range: 75 mbar...70 bar
- Output: 4...20 mA HART
- Supply: 12...30 VDC
- Operating temperature: -40…+85 °C
- Protection class: IP65
- Process connection: 1/4-18NPT
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
The FLOW 38 electromagnetic, bidirectional flow and flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. Due to the wide range of configurations available, this device is used in many industries. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing) or connected via a cable up to 30 meters long. Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids. FLOW 38 is certified for use with drinking water. There is also a version of the Flow38 with MID certification, allowing the flow meter to be used for utility metering.
- Internal pipe diameter: DN4-DN600
- Flow velocity - bidirectional (min./max.): 0.2…12 m/s
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, Rilsan, Teflon, ceramic
- Maximum working pressure: up to 100 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus), Modbus TCP/ IP, HART
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Sandwich, Food grade fittings (clamp), Thread
- Maximum ambient temperature: 55 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
- Enables the PC to be connected to HART interface, i.e. to configure a device
- Active operation: current loop is supplied
- Passive operation: used in an existing current loop
- Included HART-Tool software
- Supply: from USB
- Galvanic isolation between USB and HART
The principle of operation of this instrument is based on a high frequency band, enabling a very accurate detection of the level of media with a small emitting angle.
- Radar level transmitter TLR designed for accurate level measurement in liquids and solids
- Reflection removal mode
- High frequency band: 77-81 GHz
- Measuring range: 10, 20, 30, 50 m
- Measuring accuracy: 2 mm
- Output signal: 4…20 mA, Modbus RS485, Hart protocol
- Bluetooth app for programming and settings
- Process temperature: -20…+200 °C*
- Process connection: Threads G 1 ½, G 1 ½ / 2, G 2 and customized flanges for all models*
- Process pressure: -1…+16 bar*
- Protection class: IP67
- Input: RTD: Pt100 (2-wire) / TC: K
- Output: relay (NC/NO)
- Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
- Operating temperature: -20...+80 °C
- Supply 24 VDC
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Input: infrared sensor (850 nm)
- Output: 4...20 mA current loop with HART interface, 2x PNP or NPN
- Measurement range: 0...10 kNTU
- Measurement rate: 10 measurements per second
- Display, LED indication
- Operating temperature: -40...+75 °C
- Protection class: IP65
- Supply: 24...30 VDC
- Sensor: Pt100 (3-wire) / TC: K (with display / without display)
- Output: HART / sensor output
- Measurement range: -50...+400 °C
- Configuration: via HART
- Operating temperature: -20...+80 °C / -30...+100 °C
- Various connection options
- Supply: 12...40 VDC (HART), CR2032 (for screen)
- Protection class: IP65
- Radar level meter GRLM-70 for continuous level measurement in liquids, mush and bulk-solid materials
- Outputs: 4...20 mA HART or RS-485 Modbus RTU
- Measurement depth: up to 40 m
- Universal usage, direct mounting into containers, silos, vessels, reservoirs, etc.
- LCD or OLED screen
- Linear measurement in non-conductive and in differently shaped containers
- Versions with stainless steel rod or rope electrodes
- Xi, Xit versions for usage in explosive areas
- Xd, XdT versions for usage in flammable dusts areas
- Supply: 18...30/33/36 VDC
- Protection class: IP67
- Rated load: 1000 / 1500 / 3000 kg
- Output: 4...20 mA HART / 10 VDC
- Function: tension / compression / tension and compression
- Vibration protection
- Operating temperature: -25...+60 °C
- Supply: out of current loop / 10 VDC
- Protection class: IP54