  • Stable long-life optical NDIR gas sensor
    Range 0...10 000/50 000 ppm CO2
    Resolution 1/100 ppm for 10K/50K range CO2​
    Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
    Remote probe option

  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
  • Stable long-life electrochemical gas sensor
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 35 ppm CO
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 125 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • Visual and acoustic alarms
  • Long-life electrochemical cell
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range 0....200 ppm CO
  • Resolution 1 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • UART digital interface
  • Visual and acoustic alarms
  • Magnetic key switching
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,5 ppm/1 ppm Cl2
  • Remote probe option
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • Electrochemical gas sensor
  • Range: 0...10 ppm Cl2
  • Resolution: 0,1 ppm Cl2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC (default), 24 VAC or 90...265 VAC
  • For methane, butane, propane and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarms at 20 / 50 % LEL
  • For methane, LPG, hydrogen and acetylene
  • Can be calibrated for metane, propane and butane
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 x relays with switch-over contacts
  • Default alarms at 10 / 25 % LEL
  • For methane, butane, propane and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • For methane, LPG, hydrogen and acetylene
  • Can be calibrated for methane, butane, propane, acetylene and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range: 0...100 % LEL
  • Resolution: 0,1 % LEL
  • Outputs 2 x relays with switch-over contacts
  • Default alarms set-points 10 / 25 % LEL
  • UART digital interface
  • Alarms: blinking LED, 85 dB buzzer
  • Metal-oxide gas sensor
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Standard calibration: methane
  • Range: 0...100 % LEL
  • Resolution: 0,1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution 0,1 / 1 / 5 ppm C2H4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution 0,1 / 1 / 5 ppm C2H4
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution: 0,1 / 1 / 1 ppm C2H4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical gas sensor
  • Range: 0...20 / 0...100 ppm C2H4O
  • Resolution: 0,1 / 1 / 5 ppm C2H4O
  • Analog output: 2 x 4...20 mA / 0a...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Default calibration: methane CH4
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL
  • Resolution: 0,1 / 1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL CH4
  • Resolution: 0,1 / 1 % LEL CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...25 % vol O2
  • Resolution: 0,01 % vol O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Long-life metal-oxide gas sensor
  • Range 0...100 % LEL H2
  • Resolution 0,1 % LEL H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 10 / 20 ppm H2S
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor option
  • Electrochemical gas sensor
  • Range: 0...100 / 0...2000 ppm H2S
  • Resolution: 0,1 / 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Long-lasting stainless steel screw electrodes
  • Measurement range: 7...20 % (-40...+125 °C)
  • Resolution: 0,1 %
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Electrode cable: FEP, -50...+200 °C, 5/10/15 m
  • Timber temperature compensation
  • Electrode length: 15 / 25 mm
  • Supply: 11...30 VDC
  • Protection class: IP68
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL CH4
  • Resolution 0,1 % LEL CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Visual and acoustic alarms
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 19,5 / 18 % vol O2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Electrochemical gas sensor
  • Range: 0...25 % O2
  • Resolution: 0,01 % O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 12...36 VDC, 24 VAC or 230 VAC