- NDIR gas sensor
- Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
- Resolution: 0.01 % vol.
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -25…+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical (CO) and optical NDIR (CO2) gas sensors
- Range: 0...100 ppm CO, 0...10000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Electrochemical gas sensors
- Range: 0...100 ppm CO, 0...20 ppm NO2
- Resolution: 1 ppm CO, 0,1 NO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Photo ionization detector
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: isobutylene
- Range: 0...40 / 0...200 ppm (isobutylene)
- Resolution: 1 / 1 ppb
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+65 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: toluene
- Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
- Resolution: 0,1 % LEL / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Panel electromagnetic devices are designed to measure the angle between phase voltage and current in one-phase and three-phase circuits
- Measured value is represented in cosine (cos φ)
- Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
- THD factor
- Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
- Digital output: RS-485 MODBUS (option)
- Protection class for front side: IP65
- Supply: 85...253 VDC/VAC
- Backlit LCD display
- Dimensions: 96 x 96 x 77 mm
Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).
Cartridge electric heating elements are designed to emit large amount of heat in a small area. The heaters are made from heat-resistant steel or brass, with kanthal wire embedded in ceramics and supplemented with magnesium oxide (MgO).
- Portable analyzer NP40 is designed for power network quality parameter analysis
- Analyses voltage and current harmonics up to 51-st, THD
- Real-time waveform display (4 voltage / 4 current)
- Measurement of TRMS currents up to 3000 A (with standard sensor)
- Half cycle RMS measurement (voltage and current)
- Measurement in 1-phase and 3-phase systems (3- and 4-wire)
- Voltage, current, harmonics, power, energy and other parameter measurement
- Graphical representation of data in a waveform and vector diagram
- Record of events: dips, swells, overvoltages
- Built-in 8 GB memory card
- Ethernet interface for remote monitoring
- USB interface for data transfer
- Color 5,6” TFT display, 320 x 240 px
- Long-life MOS or electrochemical gas sensor
- Range 0....1000 ppm NH3
- Resolution 1 ppm NH3
- Outputs 4...20 mA / 0...10 V, RS-485
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...2,5 % vol.) C2H2
- Resolution 0,1 % LEL (25 ppm) C2H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
The unit is designed for determining dielectric loss tangent and permittivity of transformer oils and other dielectric fluids according to the IEC 60247.
It is a fully automatic device that allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu.
- Applied measuring voltage: 500…2000 V a.c. sinusoidal
- Tan δ measurement range: 0,00001…1
- Tan δ measurement resolution: 1х10-5
- Tan δ measurement accuracy: ± 1 % of measurement + 0,00008
- Measurement range of relative dielectric constant ε: 1,0…15,0
- Accuracy of ε measurement: ± 1 %
- Oil temperature measurement range: 20…110 ᴼС
- Measuring cell volume: 42 cm³
- Power supply: 85...264 V a.c. (48…63 Hz)
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Versions according to DIN 43763 and DIN 43772 (form 4)
- Lengths: according to customer's specification
- Bore diameters: Ø3.5 mm, Ø7 mm
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Threads for thermometer: metric M14x1.5, M18x1.5
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Other materials, threads and dimensions
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state