This website uses cookies in order to provide better service. By using this website further you accept with this policy.

S+S Regeltechnik

S+S Regeltechnik - температура, влажность, давление, освещение, движение, датчики качества воздуха и датчики расхода и регуляторы. Радиодатчики и регуляторы, основанные на технологии EnOcean.

 

Каталоги продукции - козырная версия 2025 [EN / DE]

Каталоги продукции 2025 [EN]

 

S+S Regeltechnik videos on YouTube →

 

spluss.de →

 

Показать:
Сортировка:
  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU

  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54

  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC

  • Pressure measurement range: 0...1000 Pa, 0...5000 Pa
  • Volume flow, differential pressure measurement, filter monitoring and liquid level detection
  • Volume flow: 10...100% [m3/s][m3/min][m3/h]l/s][l/min][l/h]
  • Filter monitoring: 10...100%
  • Liquid level detection: 0 – 8...14 cm or 0 – 39...72 cm (depends on pressure range)
  • Output: 0 – 10 V, 1 x changeover contact
  • Measurement element: piezoresistive sensor
  • Application: in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spay booths, in large scale catering facilities, for filter monitoring and level measurement or for triggering frequency converters.
  • Medium: clean air, non-aggressive, non-combustible gasses

 


  • Temperature sensor MWTF is designed to measure the average temperature (S+S Regeltechnik, Germany)
  • Range: -30...80 °C
  • Measuring capillary: Ø5 mm, L=0.4 m / 3 m / 6 m / up to 20 m
  • Capillary material: Copper, plastic-coated
  • Protection class: IP65

  • Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
  • Stable long-life optical NDIR sensor
  • Response time: < 2 min
  • Output: 0...10 V arba 4...20 mA
  • Ambient temperature: 0...+ 50 ºC
  • Supply: 24 VAC/ VDC
  • Protection class: IP 30
  • Dimensions: 98 x 98 x 33 mm
  • Application: offices, hotels, convention centers, apartments, shops, etc.

  • 6-range lighting meter AHKF
  • Supply: 15...36 VDC (24 VAC for AHKF-U too)
  • Sensor: Photodiode in glass casing
  • Ranges: 0...500 Lux / 1 kLux / 2 kLux / 5 kLux / 20 kLux / 60 kLux
  • Output: 4...20 mA / 0...10 V
  • Ambient temperature: -35...70 °C
  • Accuracy: < ±10 %
  • Temperature accuracy: < ±5 %
  • Size: 72 x 64 x 37,8 mm
  • Protection type: III (EN 60730)
  • Protection class: IP 65 (EN 60529)

  • Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
  • TR-040 (external setting): 0...40 °C
  • TR-040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Relay
  • Switching capacity: 24...250 VAC (16 A)
  • Ambient temperature: -35...65 °C
  • Protection class: IP65

  • TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
  • TR-04040 (external setting): 0...40 °C/0...40 °C
  • TR-04040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Switch
  • Switching voltage / current: 24...250 V, 16 A AC
  • Ambient temperature: -35...65 °C 
  • Protection class: IP65