Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.

  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • Intelligent numerical signal processing with false reflection elimination
  • Measuring range up to 8 m or up to 20 m
  • Current output - 4...20 mA, HART communication
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapors
  • Operating temperature: -30…+70 °C
  • Protection class: IP68

  • Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • FMCW antenna radar level gauge with a range of up to 20 m
  • Teaching function to suppress false reflections
  • Display of measured values on matrix OLED or LCD display
  • Current output - 4...20 mA, HART communication
  • Manual or remote adjustment
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapours or vacuum
  • Operating temperature: -30…+70 °C

  • For continuous level measurement of diesel in trucks, building machines, locomotives, etc.
  • Output: 4...20 mA / 0...10 V / CAN
  • Direct mounting into a tank through the 5-hole flange or G1” thread
  • Arbitrary electrode length (up to 1 m)
  • Setting by means of magnetic pen
  • Ambient temperature: 9...30 VDC / 12...30 VDC / 9...30 VDC
  • Protection class: IP68

  • CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
  • Stainless steel design suitable for the food and pharmaceutical industries
  • Output: 4...20 mA with two-way HART
  • Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
  • Arbitrary electrode length (up to 20 m)
  • Display of measured values on matrix OLED or LCD display
  • Power supply: 18…36 V DC
  • Protection class: IP67

  • For continuous level measurement of liquid and bulk-solid materials
  • Output: 4...20 mA / 0...10 V
  • Universal usage, direct mounting into tanks, vessels, sumps or silos and hoppers
  • Setting using a magnetic pen
  • Possibility of linear measurement even in non-conductive or variously shaped vessels
  • LED indication
  • Versions with coated electrodes for aggressive or electrically conductive media
  • Versions for explosive areas
  • Ambient temperature: -40...85 °C
  • Supply: 9...34 VDC / 12...34 VDC
  • Protection class: IP67 / IP68

  • Detection of various types electrical conductive or non-conductive liquids (water, water solution, cooling liquids, oil, ets.)
  • Direct mounting into various containers, vessels, tanks, ets.
  • Output: S, PNP, NAMUR (for explosive areas)
  • Sensitivity setting by means of magnetic pen
  • High temperature performance, pressure resistance up to 7 MPa
  • Process coupling: thread M18, M20, G3/8“ or 1/2–14 NPT
  • Versions for usage in explosive areas
  • Supply: 6…30 VDC
  • Protection class: IP68

  • Universal use for limit level sensing of liquids and bulk solids
  • Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
  • Output: NPN, PNP, NAMUR (for explosive areas)
  • Sensitivity and hysteresis fluently adjustable
  • Process coupling: thread M27x2; M30x1.5; G3/4“ or Triclamp
  • Indication by LED
  • Versions for explosive and flammable areas
  • Supply: 7…36 VDC
  • Protection class: IP67

  • Universal use for limit level sensing of liquids and bulk solids.
  • Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
  • Output: NPN, PNP
  • Setting using a magnetic pen
  • High stability upon high sensitivity (possible to use for materials with εr ≥ 1.3)
  • Indication by two LEDs
  • Versions for explosive areas
  • Supply: 8…9 VDC
  • Protection class: IP67 / IP68

High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting

  • High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting,
  • Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
  • Unique material type resolution function "Medium window" (the sensor is sensitive only to the set medium and does not react to substances with lower and higher permittivity)
  • Can replace vibration level sensors
  • Universal design for all types of liquids (electrically conductive or non-conductive)
  • For vertical mounting
  • Adjustment with a magnetic pen before installation

RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.

  • The RFLS-53 uses the principle of high-frequency capacitive measurement
  • It responds to the mass of the material and ignores deposits and material residues on the measuring part
  • For demanding applications to indicate powder, dust and hygroscopic materials
  • The sensor is available in several versions with different types of outputs and electrical connections
  • The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)

  • For continuous level measurement in non-pressure tanks, vessels and pipes
  • Output: 4...20 mA / 0...10 V
  • Measuring range up to 100 m (H2O)
  • High long-term stability
  • Accuracy: 0,5 % within the total range
  • LED indication
  • Operating temperature: -20...+70 °C
  • Supply: 12...34 VDC
  • Protection class: IP67 / IP68

Hydrostatic pressure transmitter HLM-25S is designed for level measurement in non-aggressive fluids in non-pressure tanks, boring holes, wells. Measuring range is up to 100 m in water. Current or voltage output.


  • For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls
  • Output: switch or PNP
  • Sensitivity setting by means of magnetic pen
  • LED indication
  • Prismatic or planar electrode
  • Versions with a fixed cable or a connector
  • Supply: 6...30 VDC
  • Operating temperature: -20...+80 °C
  • Protection class: IP67

  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68

Hydrostatic level meter HLM–25C is compact measuring device containing ceramic tensometric sensor and evaluation electronics in stainless steel probe. Ceramic sensor is resistant to lightly soiled, or sludge water. From the probe housing comes out 2-wire cable with capillary (for atmospheric pressure compensation). The front side of the sensor is open, therefore the level meter is resistant to capture gross (solid) impurities.

  • For continuous level measurement of clean, lightly soiled, or sludge water in non-pressure reservoirs, boreholes, tanks etc.
  • The measurement range up to 100 m (H2O)
  • The health certificate for contact with potable water available
  • Output: 4…20 mA or 0…10 V

Submersible level sensor CLS–23S is developed as reliable and low-cost solution for limit level sensing of water (or water solutions) with miniature outer dimensions without the needs of any adjustment. The connection is done by means of two wires directly to a circuit with relay or to binary input of control system.

  • For level detection of water in wells, boreholes or tanks
  • Two-wire connection directly to the relay circuit or PLC input (current switch)
  • Maximum immersion depth 100 m
  • Stainless steel protection basket avoids mechanical damages of electrode
  • Supply voltage: 6…30 VDC
  • Protection class: IP68

  • Flow and temperature sensor for liquids in pipes
  • Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
  • Flow measurement range: 1...150 cm/s (water)
  • Temperature measurement switching points: 15, 30, 45, 60, 75 °C
  • Flow rate measurement is shown in a bar graph by five green LEDs
  • Settings provided by magnetic pen
  • Stainless steel case
  • Supply: 12...34 VDC
  • Ambient temperature: -20...+80 °C
  • Protection class: IP67 / IP68

  • For continuous non-contact water level measurement in outdoor applications - rivers, canals, sumps, liquid and slurry, pastes and bulk materials
  • Remote installation and communication via HART® protocol
  • Output: 4…20 mA, HART®
  • Variable installation thanks to the possibility of connection via lower or upper thread
  • Intelligent numerical signal processing with the elimination of false reflections
  • Protection class: IP68
  • With the help of a directional funnel it is possible to increase the reception of the reflected echo and to measure problematic media (foaming levels, loose materials, etc.)
  • Operating temperature: -30…+60…+70 °C

  • Ultrasonic level sensor ULS-53 is designed for non-contact level sensing of various liquid and bulk-solid materials in closed or open tank, vessels, sumps, reservoirs etc.
  • Adjustment are made by two buttons or by magnetic pen
  • State indication by two LEDs
  • Output:
    • PNP transistor with an open collector (max. switch current 300 mA)
    • Two-state current switch 4…20 mA
  • Xi version for usage in explosive areas

  • Supplies and controls NAMUR sensors (1 or 2 channels)
  • Relay or transistor output
  • Output voltage: 9,2 VDC
  • High frequency switching (up to 2 kHz)
  • DIN rail-mounted
  • LED indication
  • Supply: 24 VDC / 230 VAC
  • Operating temperature: -20...60 °C
  • Protection class: IP20

Level sensor with elimination of rests or foam on the electrode:

  • Designed for reliable limit level sensing of wide-range of fluids (electrically conductive or non-conductive), mashed and paste-like materials
  • Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
  • Replacement of vibration level sensors
  • Unique function for media recognition “Medium window” (sensor is sensitive only to set medium and does not react to substances with a lower or higher permittivity)
  • Direct mounting into tanks, vessels, sumps, pipes or funnels and containers
  • Settings by the magic pen (included)

Вы можете использовать его для определения предельного уровня жидкости в непроводящих резервуарах (через непроводящую стенку сосуда или трубопровода).

Датчик оснащен высокочастотной технологией, обеспечивающей надежную работу даже в случае прилипания проводящих сред.

Миниатюрные характеристики в гибком корпусе, возможность установки на слегка изогнутых поверхностях.

Крепится с помощью самоклеящегося слоя или специальных крепежных лент.

Конфигурирование и настройка с помощью «программирующего» кабеля или магнитной ручки.

LED индикация состояния.


CLM-36 are designed for continuous level measurement of liquids and bulk-solid materials. Mounted directly in containers, tanks, etc. Indicator LDU-410 can be mounted on head. Can be used in high temperature and explosive atmospheres. Current (4...20 mA) or voltage (0...10 V) output.


  • For galvanic separation of current signal between explosive (Ex) and normal areas
  • Input: 0...20 mA, 4...20 mA
  • Output: 0...20 mA, 4...20 mA, version with 0...10 V
  • Version with support for HART signal
  • DIN rail-mounted
  • Supply: 24 VDC / 230 VAC
  • Operating temperature: -20...60 °C
  • Protection class: IP20

  • Radar level meter GRLM-70 for continuous level measurement in liquids, mush and bulk-solid materials
  • Outputs: 4...20 mA HART or RS-485 Modbus RTU
  • Measurement depth: up to 40 m
  • Universal usage, direct mounting into containers, silos, vessels, reservoirs, etc.
  • LCD or OLED screen
  • Linear measurement in non-conductive and in differently shaped containers
  • Versions with stainless steel rod or rope electrodes
  • Xi, Xit versions for usage in explosive areas
  • Xd, XdT versions for usage in flammable dusts areas
  • Supply: 18...30/33/36 VDC
  • Protection class: IP67

Ultrasonic level meter ULM-53 is designed for continuous liquid (even if polluted), mash and paste materials level measurements in closed and open tanks, sumps, open channels, etc. Adjustments are made with two buttons. State indication by two LEDs. Current (4...20 mA, 20...4 mA) or voltage (0...10 V, 10...0 V) outputs. Xi version is for usage in explosive areas.


ULM-70 is designed for continuous non-contact level measurements. Suitable for usage in various liquids and bulk-solid materials. OLED display. Fast measured values representation on display. Current (4...20 mA) output with HART protocol. Xi version for usage in explosive atmosphere.


Loading...