- Thermocouple with small measurement tip TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
- Sensor type: thermocouple K (NiCr-NiAl), class 2
- Measurement range: -75 °C to +250 °C
- Connection: mini connector
- Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
- Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Multipoint temperature sensor AUREGIS TJ-D is designed for temperature measurement in different levels of measured environment
- Temperature sensors can be put in one casing or in separate casings
- When they are put in separate casings, measurement points can be spread in various places vertically and horizontally
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
- Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
- Mounted on 35 mm DIN rail
- The system is designed to monitor pressure and flow rate of medical gasses
- Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
- SCADA software enables the visualization of the process
- Data is logged annd represented on the computer screen
- Values can also be represented in graphs
- The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
- The data is gathered from various measuring devices and conveyed into a PLC
- PLC and SCADA interface is MODBUS TCP
- Manual and automatic control is available
- Marameters can be changed via SCADA (IGSS) software
- All data is logged
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state
- Electrode level sensor AUREGIS LJ-B for level measurement
- Process temperature: From -30 to 180°C
- Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
- LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
- Process temperature: -20...+80 °C
Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.