- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.10 % FS
- Output: 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.25 % FS
- Output: 0...5 VDC / 0...10 VDC / 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel
- Diameter: 19 mm
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Certificate: ATEX
- Various level measurement ranges: 10...100 m H2O
- Accuracy: ≤ ± 0.50 / 0.25
- Output: 0...10 VDC / 4...20 mA
- Process temperature: -5...50 °C
- Operating temperature: -5...50 °C
- Materials: stainless steel, titanium
- Diameter: 10 mm
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Recalibration with software possible
- Output: 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Various level measurement ranges: 1...250 m H2O
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Output: 4...20 mA
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Certificate: ATEX
- Level measurement range: 0...250 m H2O
- Temperature measurement range: -5...80 °C
- Accuracy: ≤ ± 0.05 % FS
- Output: RS-485
- Process temperature: -5...80 °C
- Operating temperature: -5...80 °C
- Materials: stainless steel, titanium
- Supply: battery (up to 10 years)
- Memory: up to 1,5 million values per channel
- Pressure transmitter ATM (analog output)
- Pressure measurement range: from 0 to 0,1...1000 bar
- Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
- Process temperature: -40...150 °C
- Operating temperature: -25..85 °C
- Materials: stainless steel, titanium
- Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -40...125 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Pressure transmitter ATM/Ex (for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC
- Pressure transmitter ATM/F (hygienic)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...100 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Certificates: ATEX, EAC
- Pressure transmitter PTM (programmable)
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, EAC
- Various pressure measurement ranges: 0,1...1000 bar
- Temperature measurement range: -25...85 °C
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 2 x 4...20 mA
- Digital output: RS-485
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Relay output: 2 units
- Output: 0...20 mA / 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium