  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 % FS
  • Output: 0...5 VDC / 0...10 VDC / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel
  • Diameter: 19 mm

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificate: ATEX

  • Various level measurement ranges: 10...100 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • Output: 0...10 VDC / 4...20 mA
  • Process temperature: -5...50 °C
  • Operating temperature: -5...50 °C
  • Materials: stainless steel, titanium
  • Diameter: 10 mm

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Recalibration with software possible
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium

  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificate: ATEX

  • Level measurement range: 0...250 m H2O
  • Temperature measurement range: -5...80 °C
  • Accuracy: ≤ ± 0.05 % FS
  • Output: RS-485
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Supply: battery (up to 10 years)
  • Memory: up to 1,5 million values per channel

  • Pressure transmitter ATM (analog output)
  • Pressure measurement range: from 0 to 0,1...1000 bar
  • Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Process temperature: -40...150 °C
  • Operating temperature: -25..85 °C
  • Materials: stainless steel, titanium

  • Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -40...125 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds

  • Pressure transmitter ATM/Ex (for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC

  • Pressure transmitter ATM/F (hygienic)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...100 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel

  • Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel
  • Certificates: ATEX, EAC

  • Pressure transmitter PTM (programmable)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium

  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, EAC

  • Various pressure measurement ranges: 0,1...1000 bar
  • Temperature measurement range: -25...85 °C
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 2 x 4...20 mA
  • Digital output: RS-485
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium

  • Various pressure measurement ranges: 0,1...1000 bar
  • Relay output: 2 units
  • Output: 0...20 mA / 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium