Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.

  • Temperature range: -30...+70°C
    • Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
    • Resolution: 0.1
  • Humidity range: 0...100 % RH
    • Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
  • Memory: 32000 (16000 temperature and 16000 humidity)
  • USB interface for data download
  • Logging interval: 15 s...10000 min
  • Supply: 2xAA battery, 3.6 V
  • Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
  • Size: 45 x 100 x 19 mm
  • Temperature range: -30...70 °C
  • Accuracy: ±0,5 °C (-10 °C...40 °C) / ± 1 °C
  • Display: LCD
  • Battery work time: 2 years
  • Battery type: 1/2 AA (3,6 V)
  • Dimensions: 45x100x19 mm
  • Protection class: IP65
  • Weight: 85 g
  • Holder is ordered separately
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to DIN 43763 and DIN 43772 (form 4)
  • Lengths: according to customer's specification
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Threads for thermometer: metric M14x1.5, M18x1.5
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Other materials, threads and dimensions
  • Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
  • Ranges: -200...+150°C; -200...+550°C; -200...+600°C
  • Outputs: RTD, 4..20 mA
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
  • Exi RTD sensors for explosive atmospheres with cable
  • Range: -50 .. +400°C
  • Cable insulation: PVC, silicone, teflon, glass fiber
Exi RTD sensors for explosive atmospheres with connection head. Technical specifications Example Model Range Diameter Output XI-TOPGB / XI-APTOPGB -200 .. +150°C Ø9, Ø10, Ø11, Ø12, Ø15 mm RTD, 4..20 mA XI-TOPG / XI-APTOPG -200 .. +550°C Ø11, Ø12, Ø14, Ø15 mm RTD, 4..20 mA XI-TOPT / XI-APTOPT -200 ...
Exi RTD sensors for explosive atmospheres with mineral insulation. Technical specifications Example Model Range Diameter XI-TOPI / XI-APTOPI -200 .. +600°C Ø3, Ø4.5, Ø6, Ø8 mm XI-TRP-BTW -50 .. +600°C Ø1.5, Ø2, Ø3 mm XI-TRP-WL -50 .. +600°C Ø1.5, Ø2, Ø3, Ø4.5, Ø6 mm XI-TRP-TKbW ..
  • Exi thermocouple sensors for explosive atmospheres
  • Range: -40...+1200°C
  • Exi thermocouple sensors for explosive atmospheres with cable
  • Range: -40...+400°C
  • Exi thermocouple sensors for explosive atmospheres with connection head
  • Outputs: TC, 4..20 mA
Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..
  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446
Multipoint thermocouple temperature sensor TTP-328 is designed for temperature measurement. Suitable for energetics, oil and chemistry industries Every sensor is made out of mineral-insulted cable Process connection is threaded or flanged Compact design Maximum immersion depth is 30 m ATEX design Various variants are possible, depending on client’s request Every sensor can be mounted by up to 24 temperature transmitters. In order to bring the start-up cost down, sensor can be configured by our company. More on TTP-328 multipoint thermocou..

Instrument PH135 is designed for liquid pH, ORP and temperature measurement.

  • pH measuring range: -1.00/15.00 pH, accuracy 0.01 pH
  • ORP measuring range: -1200/+1200 mV, accuracy 1 mV
  • Temperature measuring ranges: -10.0/+110.0 °C ;  -14.0/+230.0 °F
  • Alphanumeric LCD display
  • Manual and automatic temperature compensation
  • Manual or automatic calibration
  • Automatic recognition of buffer solutions
  • Data logging up to 100 measures
  • Alcaline 9 V battery
  • Dimensions: 92 x 155 x 33 mm  -  Weight:  approx. 300 g 
RTD sensors TOPE with cable. Technical specifications Example Model Range Protective tube Cable insulation TOPE150 -50 .. +400°C Ø5, Ø6, Ø8, Ø9, Ø10 mm PVC, silicone, teflon, glass fiber TOPE3 -50 .. +400°C Ø5, Ø6, Ø8 mm TOPE4   TOPE310 -50 .. +400°C Ø5, Ø6, Ø8 mm ..
RTD sensors TOP with connection head. Technical specifications Example Model Range Accuracy Tube diameter TOPGB -50…+150°C A class (standard)orB  class according to EN 60751 various variants available TOPGN -200…+600°C TOPG -200…+600°C TOPI -200…+600°C ..
RTD sensors TRP with mineral insulation. Technical specifications Example Model Range Diameter TRP-NA -50 .. +600°C Ø1.5 .. Ø6.0 TRP-BTW -50 .. +600°C Ø1.5 .. Ø3.0 TRP-WL -50 .. +600°C Ø1.5 .. Ø6.0 TRP-TKbW -50 .. +600°C Ø1.5 .. Ø6.0 ..
  • Temperature measurement range: -100…+300 °C
  • Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
  • Resolution: 0.01 °C
  • Memory: 32 000 readings
  • Power supply: battery 3.6V 1/2AA
  • Operating temperature: -30…+70°C
  • Protection class: IP65
  • Wall mount available as optional accessory
  • Temperature measurement range: -100…+300 °C
  • Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
  • Resolution: 0.01 °C
  • Memory: 32 000 readings
  • Power supply: battery 3.7V 1/2AA (Charging time: 1,5 h)
  • Operating temperature: -30…+70°C
  • Protection class: IP65
  • Wall mount available as optional accessory

RTD sensors with TOPGDM, TOPGDS connectors. With threaded process connector, designed to measure temperature in pipes, tanks and canals. Measuring range is -50...+400 ºC. Can be fit with a LED display.

The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.

  • Temperature measuring range: 0… +1800 °C
  • Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
  • Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
  • Gastight process connection: (to 0.1 MPa / 1 bar)
  • Optionally the head can be installed with a local temperature display (DANWdie-LED)
  • ATEX and EAC Ex versions
  • For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444

 

 

Thermocouple sensors TTE with cable. Technical specifications Example Model Range Protective tube Cable insulation TTE310 -40 .. +400°C Ø5, Ø6, Ø8 mm PVC, silicone, teflon, glass fiber TTE311 TTE312 TTE409 -40 .. +400°C Ø5, Ø6, Ø8 mm TTE410 TTE411 -4..
Thermocouple sensors TT with connection head. Technical specifications Example Model Range Accuracy Tube* diameter TT_G -40…+800°C 1 class (standard) or 2 according to EN 60584 Various variants available TT_GB -40…+150°C TT_GN -40…+800°C TT_P -40…+800°C ..
Thermocouple sensors TTP with mineral insulation. Technical specifications Example Model Range Diameter TTP-NA -40 .. +1250°C Ø1.0 .. Ø8.0 TTP-BTW -40 .. +1250°C Ø0.25 .. Ø3.0 TTP-WL -40 .. +1250°C Ø1.0 .. Ø6.0  TTP-TKbW -40 .. +1250°C Ø0.25 .. Ø8.0 ..
  • Measurement range: -40…+180 °C
  • Type: J / K / N / T / E
  • Self-adhesive tape
  • Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
  • Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
  • Optional: connector
Thermocouples TTP-320, TTP-321, TTP-322 are suitable for temperature measurement of industrial furnace pipes. Suitable for energetics industry Suitable for oil and chemistry industries Made out of mineral-insulated cable Good vibration resistance Spiral windings for vibration protection Two possible variants, chosen according to client’s request ATEX design Thermocouple TTP-320...TTP-322 description [EN]More on TTP-320...TTP-322 thermocouples on Termoaparatura Wroclaw website [EN] ..
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to PN-79/M-53857/05
  • Threads for thermometer: metric M12x1.5, M14x1.5
  • Lengths: according to customer's specification
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Optional designs per DIN 43772 ( form 4 )
  • Other materials, threads and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
  • Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
  • Dimension tolerance according to DIN ISO 2768
  • Protection tube coated by layer of CrC to increase abrasion resistance
  • Protection tube coated by teflon® PTFE to increase corrosion resistance
  • Other materials, threads, flanges and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Temperature range: -30...+70 °C
  • Humidity range: 0...100% RH
  • Resolution in range: 0.1 °C
  • Temperature accuracy: In range -20...+40 °C: ±0,5 °C; outside of range: ±1,0 °C
  • Humidity accuracy: ± 2 %RH
  • Supply: 3.6 V (Lithium battery)
  • Battery lifetime: up to 2 years
  • Protection class: IP65
  • Size: 45 x 100 x 19 mm
  • Temperature range: -50...250 °C or -50...500 °C
  • Accuracy: ±0,03 °C
  • Resolution: 0,01 °C (switchable to 0,1 °C)
  • Display: LCD, 6 digits, backlight
  • MIN, MAX, hold functions
  • Sensor: Pt100
  • Protection class: IP65
  • Suitcase is ordered separately

Digital thermometer DT-1 is designed to be used for temperature measurements in liquids, gasses and solids in range of -50...+200 °C. The casing is made out of mechanically resistant plastic (ABS) and has special collars, protecting the device from dust, dirt and water. The measurements are conducted using a Pt1000 sensor. Special sensor construction and small size guarantee little delay and fast measurement. The results are shown in 4-digit LCD (last digit represents the decimal part). The device can be used in laboratories and industry in any conditions.

  • Thermometer DT20 for temperature measurement in smokehouses, butcheries, etc.
  • Measuring range -50...20 °C, accuracy 0,1 °C
  • Sharp-tipped probe ST-03 (4x120 mm) made of stainless, acid-resistant steel (1H18N9T)
  • Cable length 3 m
  • Operating temperature 0...40 °C
  • Supply 230 V
  • Size 130x94x81 mm
  • Ergonomic ABS casing with indicator, IP65

Digital thermometer DT-34 is designed for fluid, gas and solid body temperature measurement in range of -50°C to 270°C. Casing is made out of mechanically resistant plastic (ABS) and contains special collars for dust, dirt and water protection.

The measurements are done with a Pt1000 sensor. Special sensor construction and small size ensure little thermal inertia and fast measurement. The results are shown in a 4-digit LCD display, of which the fourth digit shows the decimal part. Negative temperatures are shown with a minus sign. The device can be used in laboratories and manufacturing for technological measurements in various conditions.

Thermometer DT-34 can be shipped with a fitting temperature sensor made according to Your requirements.

Digital thermometer ST-90 for temperature measurement from -200 to 1200 °C.

ST-90 is designed for usage with various construction K-type thermocouple sensors. The sensor is connected via MiniTherm port on the top of ST-90. The device is supplied by 9V 6F22 battery (work time up to 500 h). Indication on LCD screen (3 1/2). Special collars protect the electronics from moisture, grease and dust.

Thermometer ST-90 can be shipped with a fitting temperature sensor made according to Your requirements.

Loading...