- Measures ambient temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measuring ranges: -30...+105 °C, 0...100 %RH
- External sensor cable length: 1 / 2 / 4 m
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30 for device, IP40 for sensor
- Calibration certificate included
- Measures ambient air temperature and humidity
- Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
- Temperature measurement range (depends on probe type): -30...+80 °C / -50...+125 °C / 0...+50 °C
- Humidity measurement range: 0...100 %
- 4 channels: 4 x external temperature probes or 4 x external temperature and humidity probes
- Output: Ethernet
- Measurement interval: 2 s
- Communication protocols: WWW, Modbus TCP, SNMPv1, SOAP, XML
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Included calibration certificate
- Supply: 5 VDC
- Protection class: IP30
- Measures air temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...+80 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...105 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- External sensor cable length: 1 / 2 / 4 m
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
Temperature and humidity transmitter with 4-20mA output.
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...125 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Temperature measurement range: -90...+260 °C
- Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -30...+70 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP67
- Warranty: 3 years
- Inputs: 4 x Pt1000
- Temperature measurement range: -90...+260 °C
- Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP67
- Warranty: 3 years
- Input: 4x external Pt100 sensors
- Measuring range: -200…+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- Resolution: 0,1 °C
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: adjustable 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+70 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP20
- Warranty: 3 years
- Inputs: 4x external sensors + 1x internal temperature sensor
- 3x Thermocouple type B, J, N, S, T external temperature sensor
- Measuring range: according to the connected thermocouple
- Accuracy: ± 0,4 °C
- Resolution: 0,1 °C
- 1x PT1000 external temperature sensor
- Measurement range: -200...+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- Resolution: 0,1°C
- Internal temperature sensor
- Measuring range: -30…+70 °C
- Accuracy: ± 0,4 °C
- Resolution: 0,1 °C
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: adjustable 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+70 °C
- Supply: lithium ion 3,6 V AA battery
- Protection class: IP20
- Warranty: 3 years
- Sensor for remote temperature monitoring over the Internet (Ethernet interface)
- Webserver function
- Ideal for server, air conditioning, HVAC, warehouse, museum and factory temperature monitoring
- Remote alarm (meter sends an e-mail when the set temperature range is breached)
- Archive in CSV format
- MODBUS TCP protocol
- Calibration certificate included
- 3 year warranty
- Measurement range of external sensor: -200...+600 °C
- Operating temperature: -30...+80 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Communication protocol: WWW, ModbusTCP, SNMPv1, SOAP, XML
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
Data recorder with printer T-PRINT G0221E, G0241, designed for transportation temperature measurement.
Models:
T-PRINT G0221E – with printer,
T-PRINT G0241 – with printer and RS-232 output.
Complies with EN 12830, Class 1 and EN 13486, Class 1 standards for food transporation.
Appliance: food, pharmacy, flower, animal and other goods transportation temperature measurement. Designed to be mounted in driver’s cabin.
Temperature recorder with printer T-PRINT G0841, designed for transportation temperature measurement.
Models:
T-PRINT G0841 – with printer
T-PRINT G0841M – with integrated GSM modem
T-PRINT G0841MW – with integrated GSM modem and wireless output
T-PRINT G0841W – with wireless output
Complies with EN 12830, Class 1 and EN 13486, Class 1 standards for food transporation.
Appliance: food, pharmacy, flower, animal and other goods transportation temperature measurement. Designed to be mounted in driver’s cabin.
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Measures ambient temperature, humidity, pressure
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Calibration certificate included
- Protection class: IP30
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Open collector transistor alarm output.
- Input: 4x external temperature probes (Pt1000)
- Temperature measurement range: -90…+260 °C
- Accuracy: 0,2 in the range -90…+100
- Resolution: 0,1 °C
- Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
- Measured values can be sent to the internet storage COMET Cloud or COMET Database
- Communication protocols: HTTP(S), SMTP, Modbus TCP, HTTP POST, HTTP GET (JSON, XML)
- Alarm signalization: e-mail, acoustic, LED, SMS - additional order
- Measuring interval: 1 s
- Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
- Calibration certificate of manufacturer included
- Operating temperature: -30…+60 °C
- Supply: 5,0…5,4 VDC USB-C connector
- Protection class: IP30
- Temperature measurement range: -20…+60 °C
- Humidity measuring range: 0…95 % RH
- Dew point measuring range: -60…+60 °C
- CO2 measuring range: 0…5000 ppm
- Atmospheric pressure measuring range: 700…1100 hPa
- Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
- Measured values can be sent to the internet storage COMET Cloud or COMET Database
- Communication protocols: HTTP(S), SMTP, Modbus TCP, HTTP POST, SNMP (v1, v2c, v3), HTTP GET (JSON, XML)
- Alarm signalization: e-mail, acoustic, LED, SMS - additional order
- Measuring interval: 1 s
- Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
- Calibration certificate of manufacturer included
- Operating temperature: -30…+60 °C
- Supply: 5,0…5,4 VDC USB-C connector
- Protection class: IP30
- Inputs: 2x Pt1000 and 2 x binary input (sensors are not included)
- Binary voltage input: low level < 0,4 V; high level: > 2 V; voltage applicable 0…30 V DC
- Binary voltage-free input: switched-on state < 10 kOhm; switched-off state > 300 kOhm
- Binary input IS NOT suitable for catching the „voltage applied / not applied” states
- Temperature measurement range: -200...+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate of manufacturer included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: battery SONY Li-ion 5200mAh
- Protection class: IP20
- Warranty: 3 years
LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.
Collected data is processed and stored in the gateway, and can be accessed via a web browser.
- Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
- Individual alarm notifications based on specific sensors or contacts
- Alarm notifications via email and SMS
- Logging and review of errors and communication issues
- Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
- Dynamic data visualization in graph (curve) format via a web browser
- Data export in CSV and PNG formats
- Password-protected user interface
- No subscription required for the gateway or sensors
- Remote configuration of data transmission intervals for devices via a web browser
- Communication range from sensor to gateway:
- 15 km Outdoors (in plain sight)
- 50–200 meters indoors or up to 7–8 walls*
- LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power
- Sensor C-TH measures ambient temperature and humidity
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: C, T, or S*
- Measurement ranges
- Temperature: -40…+85 °C
- Humidity: 20…80 % RH (non condensing)
- Measurement accuracy
- Temperature: ± 0,2 °C in the range of 0…65 °C
- Humidity: ± 2 % RH in the range of 20…80 %
- Transmission interval: 60 s…1 hour*
- AES-128 encryption mode 5, profile A, custom KEY
- Power supply: ER14505 3.6V Li-SOCl2 battery (soldered)
- 14 years expected, standard configuration and operating temperature
- Sensor CX-TH measures ambient temperature and humidity
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: C, T, or S *
- Measurement ranges
- Temperature: -40…+85 °C
- Humidity: 20…80 % RH (non condensing)
- Measurement accuracy
- Temperature: ± 0,2 °C in the range of 0…65 °C
- Humidity: ± 2 % RH in the range of 20…80 %
- Transmission interval: 60 s…1 hour*
- AES-128 encryption mode 5, profile A, custom KEY
- Power supply: ER14505 3.6V Li-SOCl2 battery (soldered or optional battery holder)*
- 14 years expected, standard configuration and operating temperature
- Operating temperature: 0...+55 °C
- * - T1-mode, 150 seconds, Encryption ON, unique key (individual options should be stated before order)
- 300Mbps wireless data rates
- Tiny
- Supports AP (default), Client, Router, Repeater and Bridge modes
- Powered through a micro USB port by an included external power adapter or USB connection to a computer
- Compatible with Comet System devices which have Ethernet interface
- Input: external digital I2C probe for temperature, humidity and dew point (sensor are not included)
- Temperature measurement range and accuracy: according to the connected probe
- Humidity measurement range and accuracy: according to the connected probe
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate of manufacturer included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: Li-Ion battery A8200, 3.6 V / 5200 mAh
- Protection class: IP67
- Warranty: 3 years
- Inputs: 4 x Pt1000 (sensors are not included)
- Temperature measurement range: -200...+260 °C
- Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: battery SONY Li-ion 5200mAh
- Protection class: IP67
- Warranty: 3 years