Your shopping cart is empty!
- Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
- Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
- Modes: C1-A/B, T1 or S1 (selectable on order)
- Measurement ranges
- Temperature: -40…85 °C
- Humidity: 0…100 % RH (non-condensing)
- CO2: 0…5000 ppm (0…55 °C)
- LUX: 0,01…83000 LUX at same frequency as the human eye
- Absolute pressure: 20…100 kPa
- Sound level: 20…90 dBa at 850 Hz
- Measurement accuracy
- Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
- Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
- CO2: ± (50 ppm + 3%)
- LUX: 4 %
- Pressure: 0,4 kPa
- CO2 sensor calibrates every 20 days
- Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
- Transmission interval: every 90 seconds
- Measured values sample interval: every 6 minutes
- LED and sound indication about CO2 exceeded limit
- Device has 2 antennas for maximum range in both vertical and horizontal directions
- Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
- Up to 14 years battery lifetime, standard configuration and operating temperature
The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal to find even smallest leakages (0.1 l/min) easily even in far distances and calculate potential saving (€/year).
- 30 MEMS digital microphones for image of leaks
- Measuring distance: up to 6,5 m
- 3,5” TFT color display with touch panel
- Additional sensor input to measure: dew point, flow, pressure, and temperature (LD 510 only. See datasheet)
- Possibility to take photo of leaking parts
- Data transfer via USB to PC
- Easy data and work assignment with CS Leak Reporter cloud solution
- ISO 50001 report
- Power supply: 7,2 V lithium-ion battery (> 9 h continuous operation)
- Operating temperature: -5…+40 °C
SV23 Sensor help customers monitor spaces where cameras cannot be deployed and get insight into environmental conditions that cameras cannot detect. From protecting school bathrooms against bullying and vaping to gathering real-time insight into air quality conditions like carbon dioxide levels.
- Measurement objects:
- Vape index – for vape smoke detection, range: 0…100
- PM2.5 - concentration of particulate matter, range: 0…10000 μg/m3
- TVOC index, range: 0…500
- Motion detection – FoV (field of view): 120 °
- Noise – range 20…120 dB
- CO2 (carbon dioxide) – range: 0…40000 ppm
- AQI (Air quality Index) - range: 0…500
- Temperature – range: -5…+45 °C
- Humidity – range: 0…95 % (non-condensing)
- Cloud Storage: up to 365 days
- Connectivity: RJ-45 cable connector for Network / PoE powering IEEE 802.3af
- Receive alerts for offline sensor and device tampering
- Operating temperature range: -5…+45 °C