- 4G LTE supported frequency bands:
- B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28/ B66/B34/B38/B39/B40/B41
- 3G supported frequency bands:
- B1/B2/B4/B5/B6/B8/B19
- 2G supported frequency bands:
- B2/B3/B5/B8
- M2M communication protocols: MQTT, HTTP API (XML or JSON)
- Setup via WEB interface through the USB or remote setup with HTTP API or SMS commands
- Digital inputs: 2 “dry contacts”
- 1-Wire input (up to 4 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SMS alarms (up to 5 recipients)
- GSM Geolocation (optional)
- Firmware update over the air (FOTA)
- Operating temperature: -20...+55 °C
- Supply: 10…28 VDC
- Air flow monitor with automatic reset function (alternatively available with error memory)
- Switching point continuously adjustable, switching output 2 NO/ 2 NC
- Robust sensor design, high sensor protection class IP67, sensitive and fast air flow detection
- Examples of areas of application: Monitoring of heating registers, humidifiers, air curtain systems, dampers, fans, DDC
- Compact air flow meter with switching output (1 NO)
- Robust sensor design, protection class IP67 and compact dimensions
- Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
- Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
- Compact air flow meter with switching output (1 NO / 1 NC) with TÜV type examination (according to DIN EN 61010-1: 2011-07)
- Robust sensor design, protection class IP67 and compact dimensions, sensitive and fast air flow detection
- Media temperature up to 60 °C
- Switching point continuously adjustable between 0.1...30 m/s
- Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
- Flow monitors for water and air flows
- Robust stainless steel sensor housing for industrial environments
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Switching point sensitive and continuously adjustable both for liquids (0.03 ... 3 m/s) and for gases (0.5 ... 20 m/s)
- With switching output (1 NO/ 1 NC)
- Exemplary areas of application: Monitoring of air and water flows, cooling circuits up to 30% glycol content, pump monitoring
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...10 / 0...200 / 0...1500 ppm
- Resolution: 0,1 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
- Stable long-life metal-oxide sensor
- Range: 0…1000 / 0…2500 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...100 ppm, 0...2000 ppm H2S
- Resolution: 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL CH4
- Resolution: 0,1 / 1 % LEL CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0…250 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life optical NDIR sensor
- Range: 0…1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...25 % vol O2
- Resolution: 0,01 % vol O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.
- The RFLS-53 uses the principle of high-frequency capacitive measurement
- It responds to the mass of the material and ignores deposits and material residues on the measuring part
- For demanding applications to indicate powder, dust and hygroscopic materials
- The sensor is available in several versions with different types of outputs and electrical connections
- The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:
- High liquid level (idOil-LIQ high liquid level sensor)
- Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
- Sludge layer detection (idOil-SLU sludge sensor)
“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:
- High liquid level (idOil-LIQ high liquid level sensor)
- Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
- Sludge layer detection (idOil-SLU sludge sensor)
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
- Input: Modbus RTU – RS-485
- Output: 4-channel SPST relay contacts
- Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
- Non-volatile memory to retain and restore relay states following power outages
- Watchdog functionality for communication loss
- Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
- PID control function with accurate self-tuning
- Input: Pt100 (-200…+600 °C ± 0,5 % of full scale ± 1 digit)
- Relay output: 250 V AC (5, 8, 16 A) NO / NC
- Control algorithm: On-Off / P, PI, PD, PID (configurable)
- Soft start feature
- Selectable heating / cooling control
- In case of sensor failure, periodically, auto-periodically running or relay state can be selected
- Mountable on DIN rail
- Power supply: 230 V AC, 10…30 V DC - 8…24 V AC (selectable on order)
- Operating temperature: 0…+50 °C
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.
- Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
- Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
- Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
- Profile Controller: Up to 128 steps
- Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
- Communication: RS485 MODBUS RTU
- Power Supply: 90...270 VAC / DC (50/60Hz)
- Display: 4+4 digit, 7 segments
- Ambient temperature / humidity: 0…+50 °C / < 85%RH
- Dimensions: 52 x 52 x 76 mm
The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.
Applications: Motor protection, Server rooms, Control system
Features:
- Compact size 17.5 mm
- True RMS measurement
- Under voltage protection
- Over voltage protection
- Phase unbalance protection
- Phase failure protection
- Phase incorrect sequence protection
- Neutral failure protection
- Adjustable Nominal voltage, Trip point, Trip time delay
- Onsite selection of VLL / VLN value-based tripping
- Self-powered
- 1CO, 1CO+1CO relay configuration
- LED indication for faults
- Disabling of Over & Under Voltage fault on site is possible
Sensor SKU: 5905309601376 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Device monitor state of relays or reed switches (1 channel for input)
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327714 (IP30)
Sensor SKU: 5905309600713 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Device monitor state of relays or reed switches (1 channel for input)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Sensor's configuration can be changed remotely from the cloud or with a mobile application over Bluetooth Low Energy
- Operating temperature: -35…+70 °C
- Case IP30 protection (IP67 on request)
- Device G2-DC designed to monitor state of relays or reed switches
- Input: 2 dry contacts
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: C, T, or S (selectable on order)
- Standard T1-mode, transmission 90 seconds, encryption ON
- Transmission interval: configurable 60 s…1 h (selectable on order)
- Every message contains the contact status and battery level
- The message is sent as soon as a dry contact switch is detected
- AES-128 encryption mode 5, profile A (can be ordered with custom configuration)
- Power supply: 3.6V Li-SOCl2, AA battery
- Warning about low battery
- Up to 14 years battery lifetime, depending on configuration and operating temperature
- Operating temperature: -30…+85 °C (Recommended: +5…50 °C) (none condensing)