  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • Pressure measurement range: 600...1100 hPa
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
    • Modes: C1-A/B, T1 or S1 (selectable on order)
  • Measurement ranges
    • Temperature: -40…85 °C
    • Humidity: 0…100 % RH (non-condensing)
    • CO2: 0…5000 ppm (0…55 °C)
    • LUX: 0,01…83000 LUX at same frequency as the human eye
    • Absolute pressure: 20…100 kPa
    • Sound level: 20…90 dBa at 850 Hz
  • Measurement accuracy
    • Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
    • Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
    • CO2: ± (50 ppm + 3%)
    • LUX: 4 %
    • Pressure:  0,4 kPa
  • CO2 sensor calibrates every 20 days
  • Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
  • Transmission interval: every 90 seconds
  • Measured values sample interval: every 6 minutes
  • LED and sound indication about CO2 exceeded limit
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Up to 14 years battery lifetime, standard configuration and operating temperature
  • 1-Wire protocol ambient pressure sensor TSP200
  • Pressure measurement range: 300...1100 hPa
  • Excellent long-term stability
  • Warranty: 3 years
  • Connection: RJ-11
1-Wire CO2 and pressure sensor TSM400-1-CP New

TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.

  • CO2 measurements range: 400…5000 ppm
    • Accuracy: ± (40 ppm + 5 %)
    • Resolution: 1 ppm
    • Calibration: manual
  • Pressure measurements range: 10…1200 hPa
    • Accuracy (min): ±1.5 (25°C, 750 hPa)
    • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
    • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC
  • Sturdy
  • Hanging hook
  • 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
  • Maximal pressure measurement range: 0...7000 Pa
  • Air flow and velocity measurement
  • LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 9 V battery
  • Operating temperature: 10...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54

A and B connection threads:

G1/4, G1/2, M20x1,5, M10x1, M12x1,5, M20x1,5, G3/4, M16x1,5, M22x1,5,

Spec,  G1/2L*

*  -  left-hand thread

 

Material: stainless steel-DIN 1.4301 (AISI 304)

Note: other ordering versions possible.

  • Measures ambient air pressure
  • Measurement range: 600...1100 hPa
  • Operating temperature: -30...80 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • CO2 concentration measurement range: 0...10 000 / 50 000 ppm
  • External sensor cable length 1 / 2 / 4 m
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 10 s...24 h
  • Calibration certificate included
  • LED, acoustic alarms
  • LCD screen
  • Data can be transferred to PC via USB-C interface
  • Operating temperature: -20...+60 °C
  • Supply: battery
  • Protection class: IP54
  • Warranty: 3 years
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases

Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.

  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from 1...10 to 40...400 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C
  • Ambient temperature: -25...+85 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: membrana
  • Measured pressure from 1...10 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: 0...+80 °C
  • Ambient temperature: 0...+80 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
  • Free software for configuration and data visualization
  • Bluetooth communication for smartphones and tablets (Android and IOS)
  • Safety lock magnetic mounting with inviolability system holder (accessories)
  • Compatible with food industry environment
  • Up to 4 recordable parameters simultaneously
  • Optional calibration certificate

The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.

  • Range: from 0....60 to 0...5 kPa
  • Accuracy: ±2% (FS 20°C)
  • Allowed overpressure: 20 kPa
  • Operating temperature: -5...+60°C

Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 20…1500 Pa
  • Operating temperature: -5… +60°C

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 40…1500 Pa
  • Operating temperature: -20… +60°C
  • Pressure range: from -1...6 to -1...18 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/8" f, G1/2" m
  • Protection class: IP65

Differential pressure switch is designed for use in air and non-aggressive gasses. Made by HK Instruments (Finland).

  • To measure air and neutral gases pressure in range -10 000...10 000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -10 000...10 000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 mmH2O
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 69 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • To measure air and neutral gases pressure in range -100...100 Pa
  • Solenoid valve for auto-calibration: frequency 1…60 min
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -100...100 Pa
  • Accuracy: ± 1 % of reading ± 2 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output: 0-10 V and 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply: 24 V AC / V DC
  • To measure air and neutral gases pressure in range -1000...1000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -1000...1000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -2000...2000 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -2000...2000 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 4100 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -500...500 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -500...500 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 1400 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • PID controller
  • 2 set points (SP), chosen by binary input
  • Pressure measurement range: -250...2500 Pa
  • Output: 0...10 V
  • Input: NTC10, NTC20, Pt1000, Ni1000
  • LCD screen
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...2500 Pa
  • 8 field selectable measurement ranges (via jumper)
  • Output: 4...20 mA
  • Option: LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -10...+50°C
  • Protection class: IP54
  • Two pressure transmitters in one device
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Option: DPT-DUAL-MOD-AHU – with air flow transmitter
  • Output: Modbus RTU
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Input: 2 x  0...10 V, NTC10k, Pt1000, Ni1000, binary
  • Output: Modbus RTU
  • Temperature compensation in range of 0...50 °C
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54

Differential pressure transmitter with Modbus interface DPT-MOD-2000, DPT-MOD-3000 and DPT-MOD-5000 for usage in air and non-aggressive gasses.

Differential 8 range pressure transmitter DPT250, DPT2500 and DPT7000. Designed for usage in air and non-aggressive gasses.

  • Pressure measurement range: from 0...1 bar to 0...6 bar
  • Made to be used for air-conditioning, heating and water systems
  • For neutral fluids and non-aggressive gases, compatible with refrigerants
  • Output: 4...20 mA
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+80°C
  • Protection class: IP65
  • Input: differential pressure
  • Typical areas of use are chemical industry and process engineering
  • Measurement range: 75 mbar...70 bar
  • Output: 4...20 mA HART
  • Supply: 12...30 VDC
  • Operating temperature: -40…+85 °C
  • Protection class: IP65
  • Process connection: 1/4-18NPT
  • Pressure range: from 0...1 to 0...16 bar
  • Output signal: 4 ... 20 mA (P1–P2)
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f
  • Protection class: min. IP65
  • PID controller
  • Pressure measurement range: 0...2500 Pa / 0...7000 Pa
  • Switchable between air flow and pressure measurement
  • Output: 0...10 V / 4...20 mA
  • Option: autozero function
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • PID controller
  • Pressure measurement range: 0...2500 Pa
  • Modbus RTU communication
  • Control output: 0...10 V
  • External input: 0...10 V / thermistor / binary
  • LCD display
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Modern, simple and user-friendly service
  • Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
  • FTP server (available in controller versions with Ethernet interface)
  • Selection of PID parameters for any unit
  • For easy programming and devices configuration, LUMEL offers one common LPCon software
  • Parameter logging on SD card
  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65

The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: -0,5...0,5 to 0...100 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment

The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
  • Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Membrane in Duplex steel 1.4462
  • Pressure connection: G1/2” male, flush membrane
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
  • Pressure range: from 0...2,5 to 0...600 bar
  • Output signal: 1 or 2 PNP transistors
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67