- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- GSM modem (GPRS)
- SMS and JSON messages can be sent via GPRS data connection
- Messages can be sent on alarms and periodically
- Data can be transferred to PC via USB-C interface
- Calibration certificate of manufacturer included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
- Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
- Modes: C1-A/B, T1 or S1 (selectable on order)
- Measurement ranges
- Temperature: -40…85 °C
- Humidity: 0…100 % RH (non-condensing)
- CO2: 0…5000 ppm (0…55 °C)
- LUX: 0,01…83000 LUX at same frequency as the human eye
- Absolute pressure: 20…100 kPa
- Sound level: 20…90 dBa at 850 Hz
- Measurement accuracy
- Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
- Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
- CO2: ± (50 ppm + 3%)
- LUX: 4 %
- Pressure: 0,4 kPa
- CO2 sensor calibrates every 20 days
- Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
- Transmission interval: every 90 seconds
- Measured values sample interval: every 6 minutes
- LED and sound indication about CO2 exceeded limit
- Device has 2 antennas for maximum range in both vertical and horizontal directions
- Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
- Up to 14 years battery lifetime, standard configuration and operating temperature
- 1-Wire protocol ambient pressure sensor TSP200
- Pressure measurement range: 300...1100 hPa
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.
- CO2 measurements range: 400…5000 ppm
- Accuracy: ± (40 ppm + 5 %)
- Resolution: 1 ppm
- Calibration: manual
- Pressure measurements range: 10…1200 hPa
- Accuracy (min): ±1.5 (25°C, 750 hPa)
- Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
- Resolution: 1 hPa
- Operating temperature range: -20…+60°C
- Operating relative humidity range: 5…95% (non-condensing)
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
- Sturdy
- Hanging hook
- 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
- Maximal pressure measurement range: 0...7000 Pa
- Air flow and velocity measurement
- LCD screen
- Allowed overpressure: 25 kPa
- Supply: 9 V battery
- Operating temperature: 10...+50°C
- Protection class: IP54
- Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
- Air flow and velocity measurement
- Output: 0...10 V / 2...10 V or 4...20 mA
- Option: autozero function and LCD screen
- Allowed overpressure: 25 kPa
- Supply: 10...35 VDC
- Operating temperature: -40...+50°C (see datasheet)
- Protection class: IP54
A and B connection threads:
G1/4, G1/2, M20x1,5, M10x1, M12x1,5, M20x1,5, G3/4, M16x1,5, M22x1,5,
Spec, G1/2L*
* - left-hand thread
Material: stainless steel-DIN 1.4301 (AISI 304)
Note: other ordering versions possible.
- Measures ambient air pressure
- Measurement range: 600...1100 hPa
- Operating temperature: -30...80 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- CO2 concentration measurement range: 0...10 000 / 50 000 ppm
- External sensor cable length 1 / 2 / 4 m
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 10 s...24 h
- Calibration certificate included
- LED, acoustic alarms
- LCD screen
- Data can be transferred to PC via USB-C interface
- Operating temperature: -20...+60 °C
- Supply: battery
- Protection class: IP54
- Warranty: 3 years
- Measurement range: -40...+150 °C, -1...60 bar
- Temperature measurement accuracy: ± 1,3 °C
- Pressure measurement accuracy: ±0,5 % of full scale
- Operating temperature: -20...+50 °C
- Overload: 65 bar
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from 1...10 to 40...400 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C
- Ambient temperature: -25...+85 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: membrana
- Measured pressure from 1...10 to 10...100 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: 0...+80 °C
- Ambient temperature: 0...+80 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.
- Range: from 0....60 to 0...5 kPa
- Accuracy: ±2% (FS 20°C)
- Allowed overpressure: 20 kPa
- Operating temperature: -5...+60°C
Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 20…1500 Pa
- Operating temperature: -5… +60°C
Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.
- Range: -100…1500 Pa
- Operating temperature: -40… +60°C
Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 40…1500 Pa
- Operating temperature: -20… +60°C
- Pressure range: from -1...6 to -1...18 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/8" f, G1/2" m
- Protection class: IP65
Differential pressure switch is designed for use in air and non-aggressive gasses. Made by HK Instruments (Finland).
- To measure air and neutral gases pressure in range -10 000...10 000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -10 000...10 000 Pa
- Accuracy: ± 1.5 % of reading ± 3 mmH2O
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 69 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- To measure air and neutral gases pressure in range -100...100 Pa
- Solenoid valve for auto-calibration: frequency 1…60 min
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -100...100 Pa
- Accuracy: ± 1 % of reading ± 2 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output: 0-10 V and 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply: 24 V AC / V DC
- To measure air and neutral gases pressure in range -1000...1000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -1000...1000 Pa
- Accuracy: ± 1.5 % of reading ± 3 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -2000...2000 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -2000...2000 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 4100 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -500...500 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -500...500 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 1400 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- PID controller
- 2 set points (SP), chosen by binary input
- Pressure measurement range: -250...2500 Pa
- Output: 0...10 V
- Input: NTC10, NTC20, Pt1000, Ni1000
- LCD screen
- Temperature compensation
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Maximal pressure measurement range: 0...2500 Pa
- 8 field selectable measurement ranges (via jumper)
- Output: 4...20 mA
- Option: LCD screen
- Allowed overpressure: 25 kPa
- Supply: 10...35 VDC
- Operating temperature: -10...+50°C
- Protection class: IP54
- Two pressure transmitters in one device
- Pressure measurement range: -250...2500 / -250...7000 Pa
- Option: DPT-DUAL-MOD-AHU – with air flow transmitter
- Output: Modbus RTU
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Pressure measurement range: -250...2500 / -250...7000 Pa
- Input: 2 x 0...10 V, NTC10k, Pt1000, Ni1000, binary
- Output: Modbus RTU
- Temperature compensation in range of 0...50 °C
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
Differential pressure transmitter with Modbus interface DPT-MOD-2000, DPT-MOD-3000 and DPT-MOD-5000 for usage in air and non-aggressive gasses.
Differential 8 range pressure transmitter DPT250, DPT2500 and DPT7000. Designed for usage in air and non-aggressive gasses.
- Pressure measurement range: from 0...1 bar to 0...6 bar
- Made to be used for air-conditioning, heating and water systems
- For neutral fluids and non-aggressive gases, compatible with refrigerants
- Output: 4...20 mA
- Supply: 24 VDC/VAC
- Operating temperature: -20...+80°C
- Protection class: IP65
- Input: differential pressure
- Typical areas of use are chemical industry and process engineering
- Measurement range: 75 mbar...70 bar
- Output: 4...20 mA HART
- Supply: 12...30 VDC
- Operating temperature: -40…+85 °C
- Protection class: IP65
- Process connection: 1/4-18NPT
- Pressure range: from 0...1 to 0...16 bar
- Output signal: 4 ... 20 mA (P1–P2)
- Process temperature: -25...+125 °C
- Process connection: G1/4" f
- Protection class: min. IP65
- PID controller
- Pressure measurement range: 0...2500 Pa / 0...7000 Pa
- Switchable between air flow and pressure measurement
- Output: 0...10 V / 4...20 mA
- Option: autozero function
- Allowed overpressure: 25 kPa
- Supply: 24 VDC
- Operating temperature: -20...+50°C
- Protection class: IP54
- PID controller
- Pressure measurement range: 0...2500 Pa
- Modbus RTU communication
- Control output: 0...10 V
- External input: 0...10 V / thermistor / binary
- LCD display
- Temperature compensation
- Allowed overpressure: 25 kPa
- Supply: 24 VDC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Modern, simple and user-friendly service
- Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
- FTP server (available in controller versions with Ethernet interface)
- Selection of PID parameters for any unit
- For easy programming and devices configuration, LUMEL offers one common LPCon software
- Parameter logging on SD card
- Temperature measurement range: -35…+80 ºC
- Humidity measurement range: 0…100 % RH
- Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
- Output: Modbus RTU
- Allowed overpressure/ bellow: ± 50 kPa
- Operating temperature: 24 VAC / 15…35 VDC
- Protection class: IP 65
The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: -0,5...0,5 to 0...100 bar
- Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Measuring principle: Thin-film-on-steel
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Protection class: IP65, IP67
- Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
- Pressure range: from 0...2,5 to 0...600 bar
- Output signal: 1 or 2 PNP transistors
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67