Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

The LoRa-Log-Vape system, using LoRaWAN communication technology, is designed for detecting "vaping" and cigarette smoke. Sensors capture environmental parameters and, upon detecting an event, send a notification to the LoRaWAN receiver (gateway). The data is collected and processed in the receiver and can be viewed on a web page.

The LoRa-Log-Vape registration system consists of a wireless LoRaWAN sensor receiver and wireless Synetica “vape” sensors ENL-IAQ-Vape.