- Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
- Accuracy of active energy measurement 0.5S or 0.2S
- RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
- The dual-tariff function for energy billing applications
- 2 relay outputs
- Pulse output: SO output as pulse or alarm
- 2 digital inputs as energy consumption, pulse counting and contact status
- Measured values displayed in 10 configurable screens
- Possibility programming of current and voltage ratio without restrictions as in MID-certified products
- Measurement inputs dedicated for x/1A and x/5A current transformers
- Power supply: 100…550 V a.c. / d.c.
- DIN rail mounted
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).
- 10 time functions. With control signal and without additional signal
- 10 time ranges. Ranging from 0,1 sec. to 30 hours
- Operating voltage: 12…240 V AC / DC
- Operating power: < 4 VA
- Mounting on DIN rail
- Operating temperature: -20…+55 °C
Phase voltage controller PKF-302. The device is designed for electric motor protection from asymmetric supply and grid voltage drop. The controller has two switch outputs of which one is used for protective shutdown and another for alarm. Simplified type 333 variant.
- Channels: Shutdown and alarm
- Supply: 3x (50...230...265)V. Max 2,5W
- Frequency: 40...50...60 Hz
- Indicator: 3 x LED 3 digits
- Measuring mode: True RMS
- Activation voltage: 185 V
- Reset voltage: 195 V
- Activation time: about 1s
- Reset time: 1...999 s (optional 4 or 6 s)
- Switch outputs: 2 x switching 2A, 250V AC
- Ambient temperature: -15°C...55°C
- Mounting: 35 mm rail
- Protection class: panel IP40; connections IP20
Phase voltage controller PKF-333SZE. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.
Phase voltage controller PKF-333SZR. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.
Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems
- High accuracy class (0.2S for active energy)
- Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
- Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
- Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
- Memory of minimum and maximum values
- 2 configurable alarm outputs
- Supervisory relay mode for alarm outputs
- Password protection
- Programming of parameters using free eCon software
- Battery backup RTC
- Supply: 85...253 V ac / 90...300 V dc
- Operating temperature: -10…23…+55 °C
- Overall dimensions: 96 x 96 x 77 mm
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
- Destined to synchronize generator, wind, water turbine and similar devices connecting to the network
- Eliminate voltage difference, frequency, and phase shift angle
- Ethernet interface 10/100 base-t, RS-485 interface with Modbus RTU protocol
- Web server, Modbus TCP / IP, DHCP server
- Protection class from frontal side: IP65, terminal side: IP20
- Electrical safety CAT III measurement category
- Voltage range (resolution): 20...180 V (0,1 V), 60...480 V (0,1 V), ...1920 kV (0,01 kV)
- Voltage difference (resolution): -20...0…20 % (0,1 %)
- Frequency range (resolution): 45...65 Hz (0,001 Hz)
- Frequency difference (resolution): -10...0...10 % (0,01 %)
- Phase shift (resolution): 0...360 o (0,1 o)
The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.
Applications: Motor protection, Server rooms, Control system
Features:
- Compact size 17.5 mm
- True RMS measurement
- Under voltage protection
- Over voltage protection
- Phase unbalance protection
- Phase failure protection
- Phase incorrect sequence protection
- Neutral failure protection
- Adjustable Nominal voltage, Trip point, Trip time delay
- Onsite selection of VLL / VLN value-based tripping
- Self-powered
- 1CO, 1CO+1CO relay configuration
- LED indication for faults
- Disabling of Over & Under Voltage fault on site is possible
Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Compliance with MID certificate
- Maximum current: 40 A
- Nominal voltage: 230 V, 50 Hz
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply (pulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Protection class sensor / meter: IP67 / IP40
Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Compliance with MID certificate
- Maximum current: 80 A
- Nominal voltage: 3 x 230 / 400 V, 50 / 60 Hz
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply (pulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Protection class sensor / meter: IP67 / IP40