  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
  • Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
  • Output: 4…20 mA or 0…20 mA (Proportional change to input current)
  • Frequency range of Measuring current: 50…60 Hz
  • High electric isolation between primary conductor and output
  • Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
  • Auxiliary power supply: 24 V DC, ± 15%
  • Protection class: IP20
  • Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
  • Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
  • Accuracy of active energy measurement 0.5S or 0.2S
  • RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
  • The dual-tariff function for energy billing applications
  • 2 relay outputs
  • Pulse output: SO output as pulse or alarm
  • 2 digital inputs as energy consumption, pulse counting and contact status
  • Measured values displayed in 10 configurable screens
  • Possibility programming of current and voltage ratio without restrictions as in MID-certified products
  • Measurement inputs dedicated for x/1A and x/5A current transformers
  • Power supply: 100…550 V a.c. / d.c.
  • DIN rail mounted
  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.

  • Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
  • Nominal input current: 1A or 5A
  • True RMS measurement (up to 15th Harmonic)
  • On site programmable PT/CT ratios
  • User selectable 3ph3wire or 3ph4wire Network (for 3ph)
  • Onsite selection of Auto scroll / Fixed Screen (for 3ph)
  • 4 Digits 14mm ultra bright LED Display
  • Protection: IP54 front / IP20 back
  • Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
  • Accuracy: ±0.5% of nominal value
  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Power factor controller for reactive power compensation
  • Measures 73 power network parameters (40 visible on screen, all via Modbus RTU)
  • Relay outputs: 4 / 6 / 8
  • Programmable switch in time, switch off time and discharge time
  • Alarm message and relay output
  • Optional digital output: Modbus RTU (RS-485)
  • Optional real time clock (RTC)
  • LCD screen
  • Operating temperature: -10...+60 °C
  • Protection class (front): IP54
  • Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
  • 54 electrical network quality parameters
  • Analysis of voltage and current harmonics (up to the 51-st)
  • Color touchscreen: LCD TFT 3.5“, 320 x 240
  • 2 configurable alarm outputs
  • Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
  • Digital output: RS-485 (MODBUS)
  • Ethernet / Profinet 2.2
  • Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
  • Battery backup RTC
  • Dimensions: 96 x 96 x 77 mm
  • Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
  • Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
  • Measuring class A or A / S
  • Support the IEC 60870-5-104 communication protocol (new - option)
  • Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
  • Monitoring up to 6 additional energy meters with pulse output
  • Recording of measurements before and after events (dips & swells)
  • Configurable archives of logged values and events
  • SD card support (up to 32 GB)
  • Webserver function, FTP server, DHCP client
  • Outputs: relays, binary, analog
  • Binary inputs
  • E-mail alarms
  • Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
  • Color touchscreen: LCD TFT 5.6“
  • Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
  • IP65 protection class for front side
  • Real time clock (RTC) synchronization with NPT time server
  • Time synchronization via external GPS module - STR  receiver (new - option)
  • Designed for direct or indirect measurement of 1-phase network parameters
  • Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
  • Direct measurements up to 63 A
  • Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
  • Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
  • OLED display
  • Programmable current and voltage transformer ratios
  • Programmable via buttons or free eCon software (through USB)
  • Size: 53 x 110 x 60 mm
  • Meter N27D is designed to measure parameters of the single-phase power network
  • Direct measurements up to 63 A
  • The device measures voltage, current, frequency and active power
  • Measurements are represented in 4-digit display
  • Button enables the scrolling through available measurements
  • Mounted on standard 35 mm rail (LST-EN 62208)
  • Power network parameter meter N14 is designed for measuring of three-phase network parameters and accounting of internal energy consumption. Can be used in 3- or 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Active and reactive power measurement, active and reactive power counters, average power measurement
  • Phase, current and voltage effective value measurement
  • Network frequency measurement
  • Average active power (over set time) measurement
  • Changeable current and voltage transformer transfer coefficient values
  • Operating temperature: -30...+50 °C
  • Programmable switch output and RS-485 (MODBUS) port
  • Pulse output for remote energy accounting
  • Accuracy class: current, voltage 0,5/1,0; frequency 1,0; power 2,0; energy 1,0/2,0; tg φ 1,5
  • Power network meter ND20 is designed to measure 3-phase network parameters and to account internal energy consumption
  • Usable in 3- and 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Front panel protection class IP65
  • Harmonic, THD, watthour measurement
  • 3,5” LCD indicator
  • Analog output of 0/4...20 mA (additionally ordered)
  • Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
  • Current inputs 0,1 A and 0,25 A (for dedicated transformers)
  • Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
  • Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
  • RS-485 (MODBUS RTU) interface
  • THD factor measurement
  • Backlighted LCD 3,5”
  • Protection grade from the frontal side: IP65
  • Power network parameter measurement in 1- and 3-phase network
  • THD factor calculation
  • High accuracy class
  • Backlit LCD 3,5” display
  • RS-485 Modbus slave interface
  • Frontal protection class: IP65
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Option: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, FTP server, WWW server, DHCP client
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Additional 2 pages for harmonics presentation and 1 dedicated page for visualization in the form of an analog meter
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Optional: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, WWW server, FTP server, DHCP client
  • Measures 16 power network parameters (1- and 3-phase network)
  • Digital output: Modbus RTU (RS-485)
  • Pulse outputs: 2
  • Direct current measurement for up to 1/5 A
  • Complies with EU directive 2004/22/EC annexes B and D (MID)
  • On the MID Version, you can only program the CT Rate ONCE!
    The second time you set it up, the device will lock up and you will have to send it to the manufacturer for a reset.
  • Backlit screen
  • Operating temperature: -25...55 °C
  • Protection class: IP51
  • Measures 16 power network parameters (1- and 3-phase network)
  • Digital output: Modbus RTU (RS-485)
  • Pulse outputs: 2
  • Direct current measurement for up to 100 A
  • Complies with EU directive 2004/22/EC annexes B and D (MID)
  • On the MID Version, you can only program the CT Rate ONCE!
    The second time you set it up, the device will lock up and you will have to send it to the manufacturer for a reset.
  • Backlit screen
  • Operating temperature: -25...55 °C
  • Protection class: IP51

Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems

  • High accuracy class (0.2S for active energy)
  • Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
  • Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
  • Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
  • Memory of minimum and maximum values
  • 2 configurable alarm outputs
  • Supervisory relay mode for alarm outputs
  • Password protection
  • Programming of parameters using free eCon software
  • Battery backup RTC
  • Supply: 85...253 V ac / 90...300 V dc
  • Operating temperature: -10…23…+55 °C
  • Overall dimensions: 96 x 96 x 77 mm

Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).

  • universal inputs (1 A or 5 A, 100 V or 400 V)
  • programmable analog output ( -20 mA...+20 mA)
  • parameter transfer via RS-485 interface (Modbus RTU protocol)
  • chosen values memory (9000 records)
  • programmable current and voltage transformer coefficients
  • transducer settings are changed via „LPConfig“ software (USB)

Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.

  • Measuring ranges:
    • current 1/5 A L1...L3: 0,02...6 A
    • voltage L-N/L-L: 2,9...276/ 10...480 V
    • frequency: 45,00...66 Hz
    • active power: -1,65 kW...1,4 W...1,65 kW
    • reactive power: -1,65 kvar...1,4 var...1,65 kvar
    • apparent power: 1,4 VA...1,65 kVA
    • power factor: -1...0...1
    • active energy: 0...99 999 999,9 kWh
    • sum energy: 0...99 999 999,9 kvarh
  • Consumed power: ≤ 6 VA
  • Transformation coefficients: Ku = 1...4000, Ki = 1...10000
  • Supply: 85...253 VDC or AC 40...400 Hz
  • Ambient temperature: -10...23...+55 °C

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.