  • Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
  • Detectable gases: O2, CO, CO2, NO, NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
  • Color display screen with buttons
  • Communication: Bluetooth (mobile App), remote printer
  • Measurement storage: smartphone
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

Kuhlmann Ground Thawing Blankets are durable and weatherproof, designed to thaw frozen ground and soil, pipes, and protect equipment from freezing. They also work as curing blankets for various construction purposes.

Technical specifications:

  • Durable PVC materials.
  • Fixed temperature (70°C).
  • 2-meter power cable.
  • Special sizes produced upon request.
  • IP67 Class.
  • In normal conditions the mat thaws up to 30 cm of soil in 24 hours - or up to 60 cm in more sandy soil/ground.
  • Digital inputs: 2
  • 1-Wire input (up to 8 sensors)
  • RS-485 input (up to 8 sensors)
  • Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
  • Relay outputs: 4 (NO/NC)
  • Setup via USB or SMS
  • Data logger for up to 52 000 records
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...24 VDC
  • Enables the PC to be connected to HART interface, i.e. to configure a device
  • Active operation: current loop is supplied
  • Passive operation: used in an existing current loop
  • Included HART-Tool software
  • Supply: from USB
  • Galvanic isolation between USB and HART

RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.

  • The RFLS-53 uses the principle of high-frequency capacitive measurement
  • It responds to the mass of the material and ignores deposits and material residues on the measuring part
  • For demanding applications to indicate powder, dust and hygroscopic materials
  • The sensor is available in several versions with different types of outputs and electrical connections
  • The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
  • Temperature measurement range:
    a) Ambient model: -20...+80 °C
    b) Remote model with polycarbonate probe: -20...+80 °C
    c) Remote model with stainless steel probe: -40...180 °C
  • Relative humidity measurement range: 0...100 %
  • Calculates dew point, absolute humidity, enthalpy and combination ratio
  • 4-wire analog output: 0...5/10 V or 0/4...20 mA
  • 2 relay outputs
  • Versions with or without display
  • Protection class: IP65 (ABS V0 housing)

HST comes in three models, HST-M – standard model (IP20), HST-D – remote sensor (IP65) and HST-A – channel model (IP65).

The Kuhlmann Electro-Heat IBC Immersion Heater is an efficient solution for heating liquids in Intermediate Bulk Containers (IBCs), addressing viscosity challenges to enhance industrial productivity. Suitable for a variety of substances, it ensures consistent heating and easy liquid management. Its applications span multiple industries, including chemical processing, pharmaceuticals, food and beverage, and oil and gas. Constructed with durable stainless steel and featuring precise temperature control, this immersion heater combines performance with longevity.

Technical Specifications:

  • Surface load: 2.2 W/cm²
  • Power: 2000W
  • Supply: 230V 1-phase
  • Stainless steel tube element AISI 316L (1.4404)
  • Length of element: 950mm
  • Diameter of element: ø100mm
  • Heated zone: 300mm
  • Integrated PT100 sensor
  • Minimum level of liquid during heating: 500mm (half full)
  • Cable between heater and control unit: ~2800mm
  • Digital controller: 0-90°C

An IBC silicone base heater efficiently heats up contents in an IBC container, making it easy to discharge viscous or semi-solid products with minimal waste. The 2700W heater can heat water from 15°C to 70°C in less than 40 hours. Kuhlmann’s durable silicone base heater fits various IBC containers and is easy to install and use. It can also be mounted with a digital temperature controller for precise temperature control.

Technical Specifications:

  • Dimensions: 1035 - 851mm.
  • Materials: 100% silicone.
  • 1,5 meter power cord with no plugs.
  • 0-150°C PT100 Sensor System temperature controller (additional product).
  • Heats water from 15°C - 70°C in less than 40 hours in a fully loaded IBC Container.
  • Universal input for measuring temperature, resistance and standard signal
  • 4 alarm outputs with signaling on LED diodes
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Analog signal output: 0/4...20 mA or 0...10 V
  • Two-line LCD display
  • Mathematical functions for converting the measured value
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
  • 4 alarm outputs with signaling on led diodes, working in 7 different modes
  • Analog outputs: 0/4...20 mA or 0...10 V
  • Digital output: RS-485 / MODBUS RTU
  • Two-line LCD display
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

The CM22 provides essential video security features in a compact form. It is a 3MP (2048x1536) camera with 10 meters of IR light range, and includes people and vehicle detection for motion search and trajectory analysis. The CM22 camera, combined with the SV23 vape detector and air quality sensor, and powered by the Verkada Command cloud computing platform, creates a powerful vape prevention and logging system.

  • 30, 60 and 90 days of data retention (256…768 GB) on hardware and cloud back-up. If the connection to the Command cloud is lost, data is saved onboard and synced once the internet connection is restored
  • Easy to install: no NVR, DVR, servers or port forwarding, just PoE connection
  • Alerts: Camera status (offline), motion detection, people detection, vehicle detection, crowd detection, line-crossing detection, loitering detection
  • Privacy: live face blur, privacy regions and audit log
  • Field of view: Horizontal: 95°; Vertical: 69°; Diagonal: 130°
  • Operating temperature / humidity: -10…50 °C / 0…90 %
  • Connection and power input: RJ-45, PoE (IEEE 802.3af type 1)
  • Certifications: FCC, ICES, RCM, VCCI, CE, UKCA, EN 50155 railway compliance, UL/cUL/IEC 62368-1, NOM
  • Warranty: 5 years
  • Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
  • Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
  • Up to six gas sensors
  • CO measurement up to 50 000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations

  • Web-based configuration and control with password protection
  • 4 digital inputs for dry contacts
  • 4 analog inputs with 0-10V and 0-20mA options
  • 4 relays with normally open/normally closed contacts
  • RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
  • Monitor up to 24 channels
  • Set up to 24 independent alarms
  • SNMPv3 protocol support
  • Alarm notifications via SNMP traps
  • NTP protocol support
  • HTTP API commands
  • 4 schedules for real-time control of relay outputs
  • Custom logical functions
  • Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
  • Data logging capacity for up to 70,000 records
  • Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
  • Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
  • MODBUS TCP / IP protocol support
  • MQTT 3.1.1 protocol support
  • Rugged DIN-Rail / wall-mountable enclosure
  • Operating temperature range: -20…+55 °C

The Internal IBC Heater is a unique approach to heating viscous foodstuffs and chemicals within IBC Containers. It is designed to protect sensitive products, such as syrups, honey, treacle, molasses, fats and other viscous products that are difficult to process. Most products can be batched within a relatively short time, increasing efficiency and reducing down time.

Technical specifications:

  • Designed for insertion into 1000 litre cubic IBC but will also fit inside most IBC configurations.
  • Adjustable temperature range from 0°C to 70°C using an easy to use controller on the top of the heater.
  • 230/240 Volts - up to 2.4kW power output.
  • Finned, food safe heating element that is inserted into the IBC, thereby heating the contents directly.
  • Fast batching ability. Unique thermodynamic core that gives even temperature distribution along the heating extrusion,
  • Preventing thermal damage to the liquid contents of the IBC.
  • Non-stick industrial strength Xylon coating for easy washdown.
  • Carefully designed low Watt density to protect sensitive products.
  • Lightweight with stainless steel handles for easy insertion and extraction.
  • Even temperature distribution along the length of the heating extrusion.
  • Colored LED for power cycle and status indication.
  • 16 Amp blue industrial power plug.
  • Protective sleeve between the base of the control unit and the neck of the IBC to prevent ingress of contaminants.
  • Robust Construction:
  • IP67-rated body with potentiometer control mounted under protective see-through cover.
  • The product is sealed to ensure that all the connections and components are waterproof.
  • Robust IP67-rated aluminum case.
  • Long life heating elements.
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
  • Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
  • Coefficient: 1,0015 ± 0,01
  • Max static pressure: 2 bar
  • Temperature of use: 0…600 °C (up to 1000 °C in option)
  • Adjustable start time delay: 0...16 s
  • Operating resistance: 0...100 kΩ
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20
  • Three versions by sensitivity: NS (standard), AS (high), SR (adjustable)
  • Operating resistance: 5,6 kΩ (NS) 70 kΩ (AS) 0...100 kΩ (SR)
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20

The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 0…20 mA, 0…10 V or resistance input
  • 12 bit resolution
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • Inputs: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potentiometer
  • Relay output: 1 x NO contact, load-carrying capacity 6A / 250 V AC.; 6A / 30V DC
  • Digital output: RS-485 / MODBUS RTU
  • Auxiliary supply: 24 V DC / 24 mA
  • Mathematical functions for converting the measured value
  • Two-line LCD display (1-row 6 digits, 2-row 5 digits)
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -20...23...60 °C
  • Power supply: 40… 253 VAC / 20…300 V D

Micro-manometer HP (differential, liquid) HP5, HP10, HP15.

Micro-manometer MG (differential, liquid) MG20, MG40, MG50, MG60, MG80, MG100.

Micro-manometer TJ (differential, liquid) TJ100, TJ150, TJ300, TJ600, TJ1000.

Micro-manometer TX (differential, liquid) TX25, TX50, TX75.

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

Micro-manometric fluid AWS10, for filling.

  • Range: -250...2550 Pa
  • Maximal overpressure: 30 kPa
  • Accuracy: ±1,4 %
  • Pressure and air flow measurements from air diffusers and valves
  • Data can be uploaded on your computer for visualization and further analysis
  • Over 700 programmed valve types
  • Mediums: air and non-aggressive gases
  • Operating temperature: -10... +50 °C
  • Connection: ø 5 mm pressure hoses
  • Can be used with Pitot tube
  • 5 year warranty
  • Included: calibration certificate, 2 x 2 m PVC hoses

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
  • Measured parameters (with respective sensors):
    a) Temperature (Pt100 or thermocouple)
    b) Humidity
    c) Air quality
    d) Air velocity
    e) Airflow
    f) Tachometry
  • Two inputs for Pt100 temperature sensors (range -200...600 °C)
  • Up to 6 measurements simultaneously
  • Power supply: Lithium-Ion battery (up to 57 hours)
  • Calibration certificate, additional battery, transport case included
  • Operating temperature: 0...50 °C
  • Protection class: IP54

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20

Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.

The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.

  • 30 - 365 days (1TB - 8TB) of onboard storage
  • Redundant cloud backup and unlimited cloud-based archiving of footage
  • Sensor Resolution: 4 x 5MP (2688 x 1944)
  • Protection class / Impact rating: IP66 / IK10
  • Operating temperature: -40…+50 °C
  • Warranty: 10 Years
  • Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
  • Used for controlling pumps in traditional boosting systems, with expansion tank
  • Possible ranges: 1,5...6 bar, 4...10 bar (programmable)
  • 1- or 3-phase
  • Mounting on pipe
  • Operating temperature: 0...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP44
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply
  • Configurable by the software DEV9K
  • Galvanic isolation  on all the ways (1500 VAC)
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
  • Configurable by the software DEV9K
  • Capable to connect the sensors to the analog inputs
  • Galvanic isolation on all the ways (1500 VAC)

The principle of operation of this instrument is based on a high frequency band, enabling a very accurate detection of the level of media with a small emitting angle.

  • Radar level transmitter TLR designed for accurate level measurement in liquids and solids
  • Reflection removal mode
  • High frequency band: 77-81 GHz
  • Measuring range: 10, 20, 30, 50 m
  • Measuring accuracy: 2 mm
  • Output signal: 4…20 mA, Modbus RS485, Hart protocol
  • Bluetooth app for programming and settings
  • Process temperature: -20…+200 °C*
  • Process connection: Threads G 1 ½, G 1 ½ / 2, G 2 and customized flanges for all models*
  • Process pressure: -1…+16 bar*
  • Protection class: IP67
  • Measurement range: -40...+150 °C
  • Temperature measurement accuracy: ± 1,3 °C
  • Operating temperature: -20...+50 °C
  • Used with wireless manifold
  • Cable of 2 m length
  • 124 refrigerant gases
  • Pressure measurement range: -1...60 bar
  • Pressure measurement accuracy: ± 0,5 % of full scale
  • Overload: 65 bar
  • Operating temperature: -20...+50 °C
  • Used with wireless manifold
  • 124 refrigerant gases
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
  • The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • With integrated K type thermocouple
  • Accuracy: 1 %
  • Coefficient: 0,84 ± 0,01
  • Static pressure: Atmospheric
  • Temperature of use: 0…1000 °C

Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.

29.89 €
Ex Tax: 24.70 €

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C
  • Temperature sensor AUREGIS TJ-H with hygienic – food process connection and M12x1 4 pin connector
  • Sensor type: RTD (Pt100, Pt1000), TC (K, J)
  • Accuracy: A or B
  • Measuring range: from -50°C to 400°C
  • Sensor tube:
  • Length: 100, 180, 200 mm
  • Diameter: Ø6/8/10 mm
  • Material: stainless steel
  • Process connection tread: G1/2
  • Transmitter output type: 4...20 mA, 4...20 +HART, 0-10 V, RS-485 other parameters acc. to requirement
  • Cable connector: M12x1 4 pin
  • Various sizes are available depending on customer requirements and drawings
  • Sensor: Pt100 / Pt1000 / 2x Pt100 / 2x Pt1000, 2 / 3 / 4-wire
  • Output: 4..20 mA HART / RTD / CANopen
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Fitting length: 50...1000 mm
  • Process connection: G1/2”, hygienic
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Supply: 12...40 VDC (HART), 8...40 VDC (CANopen)
  • Protection class: IP65
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65
Loading...