1-Wire CO2 and pressure sensor TSM400-1-CP New

TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.

  • CO2 measurements range: 400…5000 ppm
    • Accuracy: ± (40 ppm + 5 %)
    • Resolution: 1 ppm
    • Calibration: manual
  • Pressure measurements range: 10…1200 hPa
    • Accuracy (min): ±1.5 (25°C, 750 hPa)
    • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
    • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC

TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.

  • Temperature measurement range: -20…+60°C
    • Accuracy (min): ± 0,4 °C (in -10…+60°C range)
    • Accuracy (max): ± 0,6 °C (in -20…+60°C range)
    • Resolution: 0,1 °C
  • Relative humidity measurement range: 10 to 90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0,1 %RH
  • Excellent long-term stability
  • The unique 64-Bit serial number for multi-sensors support
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC

SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air

  • Changeable communication parameters
  • Non-volatile memory for all settings
  • Operating temperature range: -20…60°C
    • Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
    • Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
    • Resolution: 0.1 °C
  • Operating relative humidity range: 10…90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0.1 % RH
  • Ingress protection: IP20
  • Operating voltage range: 4.5…26 VDC

TSM400-4-CP is a multi parameters sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures barometric pressure and CO2 concentration.. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.

  • Changeable bitrate and other communication parameters
  • Non-volatile memory for all setting
  • CO2 measurements range: 400…5000 ppm
  • Accuracy: ± (40 ppm + 5 %)
  • Resolution: 1 ppm
  • Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
  • Pressure measurements range: 10…1200 hPa
  • Accuracy (min): ±1.5 (25°C, 750 hPa)
  • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
  • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC