  • Meter to measurements electric quality parameters in 3 phase systems
  • Programmable display pages
  • 3 programmable alarm outputs and 1 pulse output
  • Digital transmission to the master system through the RS-485 interface
  • USB for configuration by using free eCon software
  • Molded epoxy resin protects against aggressive environmental factors
  • Primary current: 60...160 A or 200...320 A
  • Secondary current: 1 A or 5 A
  • Hole diameter: 30 mm or 50 mm
  • Hole depth: 50 mm or 40 mm
  • Accuracy class: 1
  • LW and LE series of current transformers with a round hole for a cable
  • Ranges of primary current from 50A up to 5000A
  • Maximum operating voltage 0,72 kV
  • Secondary current: 1A or 5A
  • Accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1; 3
  • Terminals of the secondary circuit are protected by cover that protects them against accidental contact
  • Operating temperature: -10…+55 °C
  • Signal splitter DAT5022
  • Configurable with switches on body
  • 3-way galvanic isolation (2000 VAC)
  • Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
  • Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
  • Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
  • Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
  • Environment: -20...+70 °C / (non-condensing) 0-90%
  • Housing: Self-extinguishing material
  • EMC
    • Immunity: EN 61000-6-2
    • Emission: EN 61000-6-4

They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.

  • Single-phase power controller (phase angle load control)
  • Control input: DC voltage 0...10 V DC (RSR92-..V..) or current 4...20 mA (RSR92-..I..)
  • SCR output (thyristors)
  • Load current 25...80 A
  • Max. load voltage 280, 530 V AC (single-phase)
  • Dielectric strength 4 000 Vrms (opto-isolation)
  • MOV protection (built-in varistor)
  • Mounting on panel or on heatsinks
  • Recognitions, certifications, directives: RoHS, REACH, CE, EAC
  • Available versions with 2 to 8 primary windings
  • Nickel plated secondary terminals
  • Multiple mounting methods, including wall mounting and on DIN rail
  • Applicable standard: IEC 61869-1/2
  • Rated primary current: (2...8) x 5 A
  • Rated secondary current: 5 A
  • Rated burden: 5 / 10 / 15 / 20 / 25 A
  • Max system voltage: 720 V
  • Operating temperature: -25...+40 °C
  • Accuracy class: 0,5 / 1
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)

They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.

  • Three-phase power controller (phase angle load control)
  • Control input: DC voltage 0...10 V DC or current 4...20 mA
  • SCR output (thyristors)
  • Load current 25...80 A
  • Max. load voltage 530 V AC (three-phase)
  • Dielectric strength 4 000 Vrms (opto-isolation)
  • MOV protection (built-in varistor)
  • Mounting on heatsinks
  • Recognitions, certifications, directives: RoHS, REACH, CE, EAC
  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
  • Protection class: IP65
  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • EDP2041 is standard signals generator (digital potentiometer) with outputs:
    • 0…10 V; Resolution: 1 mV; Fluctuation: max 30 mA; Rise time from 0 to 10V is max. 300ms
    • 0 / 4…20 mA; Accuracy: 0.1 %; Resolution: 2 µA; Fluctuation: max. 60 µA
  • Preset value can be adjusted from external buttons
  • Communication via RS-485 Modbus protocol or synchronous running between two or more potentiometers
  • Display scale can be adjusted between -1999 and 9999
  • Soft on and soft off properties can be selected
  • 4 digits display
  • Parameter access protection on 3 levels
  • Supply: 230 V AC; 24 V AC; 9…30 V DC
  • Ambient temperature: 0…50 °C
  • Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Open collector transistor alarm output.
Wireless current sensor 4…20mA with PSU, TDSCT102, TDSCT202 New

Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).

  • Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
  • Current measurement range: 0...30 mA
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Operating temperature: -30...+80 °C
  • Power supply: 85…265 VAC
    • 1 x AA battery is for to notify user in case of external
  • Protection class: IP67
  • Current measurement range: 0...30 mA
  • Operational range (in line-of-sight): up to 3 km
  • Cable length: 1 m
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Operating temperature: -40...60 °C
  • Protection class: IP68

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 40 A
  • Nominal voltage: 230 V, 50 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 80 A
  • Nominal voltage: 3 x 230 / 400 V, 50 / 60 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40
Loading...