Search
Search Criteria
Products meeting the search criteria
Show:
Sort By:
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
- Inputs: 2x Pt1000 and 2 x binary input (sensors are not included)
- Binary voltage input: low level < 0,4 V; high level: > 2 V; voltage applicable 0…30 V DC
- Binary voltage-free input: switched-on state < 10 kOhm; switched-off state > 300 kOhm
- Binary input IS NOT suitable for catching the „voltage applied / not applied” states
- Temperature measurement range: -200...+260 °C
- Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate of manufacturer included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: battery SONY Li-ion 5200mAh
- Protection class: IP20
- Warranty: 3 years