Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
- Compact air flow meter with analogue output (0…10 V & 4…20 mA)
- Robust sensor design, protection class IP67 and compact dimensions
- Media temperature up to 70 °C
- Switching point continuously adjustable between 0.1...30 m/s
- Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
- Flow monitor for liquid media in the range of 4…400 cm/s with analog (4…20 mA) and status output (PNP, NPN) for monitoring a flow threshold
- Ten LEDs indicate flow and contact closure
- Equipped with 2 control buttons for setting the switching point
- Available with 65 mm and 125 mm mounting depths
- Rugged design for industrial environments, IP67
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 0…20 mA, 0…10 V or resistance input
- 12 bit resolution
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
- Inputs: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potentiometer
- Relay output: 1 x NO contact, load-carrying capacity 6A / 250 V AC.; 6A / 30V DC
- Digital output: RS-485 / MODBUS RTU
- Auxiliary supply: 24 V DC / 24 mA
- Mathematical functions for converting the measured value
- Two-line LCD display (1-row 6 digits, 2-row 5 digits)
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -20...23...60 °C
- Power supply: 40… 253 VAC / 20…300 V D
- The module setting can be done through USB or one of the RS-485 (master/slave) interface using the available for free eCon program
- Possibility of connection via internal RS-485 port in order to increase no of analog outputs in network
- Master Modbus function dedicated to read out data from other RS-485 devices and to scale analog value.
- Slave Modbus function to set the signal on analog outputs
- Possibility of configuration through USB without power supply
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
Applications:
Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
- at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line) ≤ 55 V
- at In, C2 (8/20 μs, line-PG) ≤ 500 V
- at C3, 1 kV/µs (line-line) ≤ 48 V
- at C3, 1 kV/µs (line-PG) ≤ 600 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).
Main features:
- Sampling rate (5 times / second)
- 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
- 2 input: 0 / 4…20 mA and 0…10 V
- Binary input for changing the function of the controller and SP switching
- Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
- Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
- Programmable digital filter
- Hardware and software security before changing settings
- Alarm for breaking the control loop
- Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
- Protection class: IP65
The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.
- Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
- Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
- Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
- Profile Controller: Up to 128 steps
- Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
- Communication: RS485 MODBUS RTU
- Power Supply: 90...270 VAC / DC (50/60Hz)
- Display: 4+4 digit, 7 segments
- Ambient temperature / humidity: 0…+50 °C / < 85%RH
- Dimensions: 52 x 52 x 76 mm
- Sensor AR434 compatible with Wireless data logger AR407
- Input:
- RTD: Pt100 / Ni100
- TC: J / K / S / B / R / T / E / N
- Analog: 0…20mA / 4…20mA / 0÷10V / 0…60mV
- Resistance: 0…700Ω
- Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated requires supplying sensor via the mini-USB port)
- Built-in measurement of ambient temperature (20…70 °C)
- LCD display showing the measured values, messages and errors
- Protection: IP20
- Power supply: battery (3.6 V, AA type)
- Battery lifetime: up to 2 years, at room temperature, with measurement period > 40 min and uninterrupted radio transmission
- Parameter configuration via USB serial interface
- Variation of device without LCD screen (AR433)
- Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
- Suitable for media temperatures up to 350°C
- Measured value display by means of LCD and LED
- Freely scalable measuring range m/s, m³/h, l/min
- Sensitive and fast airflow detection up to 30 m/s
- Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches
Sensor SKU: 5905309601192 (IP30)
Sensor SKU: 5905309601482 (IP67)
Wireless 4…20 mA / 0…10 V analog signal data logger, sensor interface, BLE allows users to connect analog sensors to the cloud**. Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V). Transducer can be powered* either from the device’s battery or by an external power source.
You can use a free mobile application to configure the device and read the data from its memory. If you add Efento Gateway, you can build a remote monitoring system.
- Communication: BLE (Bluetooth Low Energy)
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery (on request 1000 mAh rechargeable battery (USB 5V))
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- External transducers can be powered by the device's battery (max. 16V, 30 mA)
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -15…+70 °C / 0…99 %
- Case IP30 protection (IP 67 on request)
Sensor SKU: 5905309600072 (IP30)
Sensor SKU: 5905309600607 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.
- Wireless 4…20 mA / 0…10 V analog signal sensor interface, data logger, NB-IoT measures analog readings and can send data over NB-IoT
- Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V)
- Transducer can be powered* either from the device’s battery or by an external power source
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -35…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection (IP67 on request)
LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.
Collected data is processed and stored in the gateway, and can be accessed via a web browser.
- Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
- Individual alarm notifications based on specific sensors or contacts
- Alarm notifications via email and SMS
- Logging and review of errors and communication issues
- Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
- Dynamic data visualization in graph (curve) format via a web browser
- Data export in CSV and PNG formats
- Password-protected user interface
- No subscription required for the gateway or sensors
- Remote configuration of data transmission intervals for devices via a web browser
- Communication range from sensor to gateway:
- 15 km Outdoors (in plain sight)
- 50–200 meters indoors or up to 7–8 walls*
- LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power