This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Triton Vape Detector  detects of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
  • Monitoring of Humidity, Particulate Matter Index and VOC Index
  • Rejects most aerosols with a similar profile to vape/smoking
  • Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
  • Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
  • Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
  • Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
  • Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
  • Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Distinguishes between vaping and smoke and counts the number of detections
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
  • Power suplly: 12…24V V DC, 0.15 Amp (max)
  • Configuration via USB cable / downlink
  • Operating Temp. / Humidity: 0…40 °C / 0…95 % RH

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20

SV23 Sensor help customers monitor spaces where cameras cannot be deployed and get insight into environmental conditions that cameras cannot detect. From protecting school bathrooms against bullying and vaping to gathering real-time insight into air quality conditions like carbon dioxide levels.

  • Measurement objects:
    • Vape index – for vape smoke detection, range: 0…100
    • PM2.5 - concentration of particulate matter, range: 0…10000 μg/m3
    • TVOC index, range: 0…500
    • Motion detection – FoV (field of view): 120 °
    • Noise – range 20…120 dB
    • CO2 (carbon dioxide) – range: 0…40000 ppm
    • AQI (Air quality Index) - range: 0…500
    • Temperature – range: -5…+45 °C
    • Humidity – range: 0…95 % (non-condensing)
  • Cloud Storage: up to 365 days
  • Connectivity: RJ-45 cable connector for Network / PoE powering IEEE 802.3af
  • Receive alerts for offline sensor and device tampering
  • Operating temperature range: -5…+45 °C
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm LEL
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Remote probe option
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 relays with switch-over contacts
  • Default alarm set-points 10 % / 25 % LEL
  • Visual and acoustic alarms
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL (0...1 % vol) toluene
  • Resolution 3 ppm toluene
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Acoustic alarm
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm toluene
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • For toluene, xylene, ethanol and 2-propanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range: 0...100 % LEL or 0…500 ppm
  • Resolution 0,1 % LEL or 1 ppm
  • Outputs: 2 relays with switch-over contacts
  • Acoustic and visual alarms
  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Sensor SKU: 5905309601321 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Indoor air quality IAQ measurement range: 0…500
  • Temperature measurement range: -35…+70 °C, accuracy up to 0,4 °C in the range from -20°C to +70°C and 0,5 °C in the range -35…-20 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy up to 4 % in 0…80 % RH and 7 % in the range 81…99 %
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327813 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Indoor air quality IAQ measurement range: 0…500
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection

The LoRa-Log-Vape system, using LoRaWAN communication technology, is designed for detecting "vaping" and cigarette smoke. Sensors capture environmental parameters and, upon detecting an event, send a notification to the LoRaWAN receiver (gateway). The data is collected and processed in the receiver and can be viewed on a web page.

The LoRa-Log-Vape registration system consists of a wireless LoRaWAN sensor receiver and wireless Synetica “vape” sensors ENL-IAQ-Vape.

  • Sensor E2-VOC measures VOC (Volatile organic compounds), ambient temperature and humidity, transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: T (C or S can be custom ordered)
    • AES-128 encryption mode 5, profile A
  • Measurement range
    • Temperature: -40…+85 °C
    • Humidity: 0…100 % RH (non condensing)
    • VOC: 0…60000 ppb
  • Measurement accuracy
    • Temperature: ± 0,2 °C in the range of +5…+55 °C
    • Humidity: ± 2 % RH in the range of 10…90 %
    • VOC: typical ± (15…25 %) of value at 25 °C / 50 % RH
  • Transmission interval: 90 s both sampling and sending. Custom sending interval on request (60 s…1 hr)
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Battery lifetime up to 14 years, depends on configuration and operating temperature
Loading...