  • Temperature sensor AUREGIS TJ-1 is inextricably connected to the cable
  • It is designed for temperature measurement from -50°C to 400°C
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years

The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 50℃
  • Operating altitude: Up to 2000 meters
  • Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

Compact sensor VA 525 for measuring compressed air or nitrogen inline.

  • 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
  • Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
  • Pressure range up to 16 bar
  • Temperature range up to 60°C
  • For speeds up to 224 Nm/s
  • Integrated display to show the measured values
  • Available from 1/4" to 2''
  • Settings adjustable via the keys of the display
  • Main counter can be reset via the display
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from  -0,6...3,4 to 4...40 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C / -40...+125 °C
  • Ambient temperature: -25...+125 °C / -40...+125 °C
  • Protection: IP65
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from 1...10 to 40...400 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C
  • Ambient temperature: -25...+85 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: membrana
  • Measured pressure from 1...10 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: 0...+80 °C
  • Ambient temperature: 0...+80 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • Compact thermostat for shipbuilding
  • ISP version – with capillary tube, ISPT version – without capillary tube
  • Measured temperature from +5...95 °C to +20...150 °C
  • Switching differential: not adjustable
  • Output signal: floating change-over contact
  • Ambient temperature: -30...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H

The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.

Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 20…1500 Pa
  • Operating temperature: -5… +60°C

Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 40…1500 Pa
  • Operating temperature: -20… +60°C
  • Pressure range: from -1...6 to -1...18 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/8" f, G1/2" m
  • Protection class: IP65

Differential pressure switch is designed for use in air and non-aggressive gasses. Made by HK Instruments (Finland).

Electromagnetic flowmeter for open channels and partially filled pipes, FLOW 55 New

Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.

  • Internal pipe diameter: DN80…DN600
  • Flow velocity (min. / max.): 0,46…7,5 m/s
  • Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
  • Process Temperature: 0…+70 °C
  • Coating materials: hard rubber
  • Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
  • Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
  • An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
  • Data archiving on a micro-SD card
  • Process connections: flange
  • Maximum ambient temperature: 55 °C
  • Power supply: 24 V AC / DC, 230 V AC
  • Protection class: IP68 for sensor, IP65-IP68 for transmitter

 

FLOW 55 datasheet [EN]

  • Exi thermocouple sensors for explosive atmospheres
  • Range: -40...+1200°C
  • Exi thermocouple sensors for explosive atmospheres with cable
  • Range: -40...+400°C
  • Exi thermocouple sensors for explosive atmospheres with connection head
  • Outputs: TC, 4..20 mA
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Float level switches AUREGIS LJ-V with an extension for level control
  • Operating temperature: -30...+130°C
  • Protection class: IP65 

Thermal mass flow sensor for compressed air and gases VA 500

  • 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
  • Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
  • Optional: Bi-directional measurement
  • Pressure tight up to 50 bar
  • Temperature range up to 110 °C
  • Protection class IP65
  • Suitable for gas velocities up to 224 Nm/s
  • Integrated display for showing the measured values
  • Can be used from 1/2" up to 40", larger diameters on request
  • Easy installation under pressure
  • Settings can be changed via the display
  • Main counter reading can be reset via the display
  • Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
  • Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
  • Output: Modbus RTU, RS-485
  • Reads data from 68 individual temperature cables and spears
  • Supply: 230 VAC / 115 VAC
  • Protection class: IP66
  • Certificates: IECEx, ATEX
  • Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
  • Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
  • Operating temperature: -20...+50 °C
  • Protection class: IP66
  • Certificates: IECEx, ATEX
  • Data logger (4 MB, up to 1 year of backup)
  • Sample rate: 60 s...18 h
  • Communication: GSM/3G/HSPA/Telstra arba GSM/2G/GPRS arba CDMA/Verizon
  • Certificates: FCC, ETSI, C-TICK
  • Option: GPS
  • 1 input: for sensors with SDI-12 interface
  • 2 input: double analog/digital/counter input or I2C interface
  • USB connection: for charging and RanchMgr communication
  • LCD screen
  • Remote control
  • Solar panel
  • Supply: battery (typical run time without sunlight is 1 month)
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø9,8 mm
  • Length: 1...35 m
  • Tensile strength: ≤ 2,5 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø17 mm
  • Length: 1...100 m
  • Tensile strength: ≤ 8 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Used with grain temperature sensor cables GWSL 1100, GWSL 2100 and spear sensors GWTL-R
  • Cable length up to 200 m (including the temperature cables)
  • Up to 32 values of temperatures are shown in cycle
  • Weight: 240 g (with batteries)
  • Case material: ABS
  • Supply: 2 x AA (battery life circa 1 year)
  • Operating temperature: -20...+40 °C

RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.

  • The RFLS-53 uses the principle of high-frequency capacitive measurement
  • It responds to the mass of the material and ignores deposits and material residues on the measuring part
  • For demanding applications to indicate powder, dust and hygroscopic materials
  • The sensor is available in several versions with different types of outputs and electrical connections
  • The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
  • SF6 gas density monitor for high voltage switchgear
  • Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
  • Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
  • Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Ambient temperature: -40...+80 °C
  • Protection class: IP65
  • Pressure range: from 0...2,5 to 0...600 bar
  • Output signal: 1 or 2 PNP transistors
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67

Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations

  • Web-based configuration and control with password protection
  • 4 digital inputs for dry contacts
  • 4 analog inputs with 0-10V and 0-20mA options
  • 4 relays with normally open/normally closed contacts
  • RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
  • Monitor up to 24 channels
  • Set up to 24 independent alarms
  • SNMPv3 protocol support
  • Alarm notifications via SNMP traps
  • NTP protocol support
  • HTTP API commands
  • 4 schedules for real-time control of relay outputs
  • Custom logical functions
  • Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
  • Data logging capacity for up to 70,000 records
  • Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
  • Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
  • MODBUS TCP / IP protocol support
  • MQTT 3.1.1 protocol support
  • Rugged DIN-Rail / wall-mountable enclosure
  • Operating temperature range: -20…+55 °C
Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..
  • For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls
  • Output: switch or PNP
  • Sensitivity setting by means of magnetic pen
  • LED indication
  • Prismatic or planar electrode
  • Versions with a fixed cable or a connector
  • Supply: 6...30 VDC
  • Operating temperature: -20...+80 °C
  • Protection class: IP67
  • Output: switch
  • Application: level sensing for solids
  • Supply: 24 VDC / 220 VAC
  • Sensitivity setting: 3 positions
  • Rotation speed: 1 per minute
  • Operating temperature: -20...+70 °C
  • Operating pressure: up to 0,8 bar
  • Material: body – plastic, other component – stainless steel
  • Protection class: IP65
  • Weight: 1 kg
  • Input: Modbus RTU – RS-485
  • Output: 4-channel SPST relay contacts
  • Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
  • Non-volatile memory to retain and restore relay states following power outages
  • Watchdog functionality for communication loss
  • Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years

The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.

  • Connection connector: M12 (4 / 8 pins)
  • Floats and float holders are customizable (on request)
  • Connection thread: G3/4" or larger (on request)
  • Switching power: 25 VA
  • Switching voltage: 24 V AC/DC
  • Process part operating temperature: -30...+105 °C
  • Process part: Stainless steel AISI316L
  • Protection class: IP65
  • Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
  • Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Multipoint float level switches LJ-VDT for fluid level measurement and control
  • Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Grain temperature monitoring system software for PC
  • Collects data from temperature cables GWSL 1100 and GWSL 2100 and spear temperature sensors GWTL-R
  • Stores, visualizes data in charts
  • Alarms
  • Level indication
  • Pressure range: from -0,9...1,5 to 4...40 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/2" m
  • Protection class: IP66
Differential pressure switch EXPD 920/924/932. Technical specifications Range -1...18 bar Accuracy  ±2 % Output Switch Switching voltage, current 250 VDC, 0,25 A 250 VAC, 5 A 30 VDC, 5 A Ambient temperature -30...+65 °C Process temperature < 150 °C  Protection class IP65 Process connection ..
  • Pressure range: from 1...10 to 60...600 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -30...+100 °C / -15...+150 °C
  • Process connection: G1/4" f, G1/2" m
  • Protection class: IP66
Pressure switch PSTD 9D0 for differential pressure measurement with variable differential. Technical specifications Range -1...8 bar Accuracy ±1% Output switch Switching voltage, current 250 VAC, 10 A 250 VDC, 0,1 A 220 VDC, 0,25 A 110 VDC, 0,5 A 24 VDC, 2 A Ambient temperature -25...85 °C Process temperature < 120 °C  Protec..
  • Used for controlling pumps in traditional boosting systems, with expansion tank
  • Possible ranges: 1,5...6 bar, 4...10 bar (programmable)
  • 1- or 3-phase
  • Mounting on pipe
  • Operating temperature: 0...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP44
  • Pressure range: from 0...2,5 to 0...600 bar
  • Output signal: 1 or 2 PNP transistors
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: bellow
  • Measured pressure from -0,9...1,5 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -40...+150 °C
  • Ambient temperature: -25...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • Various pressure measurement ranges: 0,1...1000 bar
  • Relay output: 2 units
  • Output: 0...20 mA / 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.

  • TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
  • User-friendly WEB interface for easy configuration and control
  • Free version let monitor up to 10 items
  • The monitored parameters can be sensors, digital and analog inputs and relay outputs
  • Graphical and Data dashboards for better visualization
  • TC Monitor allows flexible administration of user accounts
  • Easy access to the raw data tables, export in .csv format
  • Alarm notifications
  • User activities log
Loading...