This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Triton Vape Detector  detects of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
  • Monitoring of Humidity, Particulate Matter Index and VOC Index
  • Rejects most aerosols with a similar profile to vape/smoking
  • Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
  • Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
  • Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
  • Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
  • Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
  • Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V
  • Digital pulse counter - tachometer ECH4400
  • Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
  • Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
  • Control outputs: 2 relay NO / NC 250 V, 2 A
  • SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
  • RS485 Modbus communication interface (custom ordered)
  • Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
  • Auxiliary supply output: 12 VDC, max 50 mA
  • Ambient temperature: 0…+50 °C
  • Case protection: front panel IP65, rear panel IP20

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

A simple handheld, accurate vape particulate, vape smoke detector FD-VAPE-HAND that indicates air quality for home, work, vehicles, or other occupational spaces. Excellent to detect vape, cigarette smoke, and e-cig smoke.

  • Sensor: Laser scattering PM1.0, PM2.5, PM10 sensor
  • Detection Range: 0-1000 µg/m3
  • Response Time: <10 seconds
  • Temperature measurement range: 0…50 °C (can be selected between Fahrenheit and Celsius)
  • Humidity measurement range: 10…95 %RH
  • Sound alarm when vape detected
  • Auto off: after 5 minutes
  • Power: 1000 mAh Li-Ion Battery, up to 8 hours of operation, (recharge USB 5V/1A)
  • Dimensions: 5,1 x 1,8 x 8,6 cm
  • Weight: 142 gr

The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Distinguishes between vaping and smoke and counts the number of detections
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
  • Power suplly: 12…24V V DC, 0.15 Amp (max)
  • Configuration via USB cable / downlink
  • Operating Temp. / Humidity: 0…40 °C / 0…95 % RH

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20

Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.

29.89 €
Ex Tax: 24.70 €

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C

SV23 Sensor help customers monitor spaces where cameras cannot be deployed and get insight into environmental conditions that cameras cannot detect. From protecting school bathrooms against bullying and vaping to gathering real-time insight into air quality conditions like carbon dioxide levels.

  • Measurement objects:
    • Vape index – for vape smoke detection, range: 0…100
    • PM2.5 - concentration of particulate matter, range: 0…10000 μg/m3
    • TVOC index, range: 0…500
    • Motion detection – FoV (field of view): 120 °
    • Noise – range 20…120 dB
    • CO2 (carbon dioxide) – range: 0…40000 ppm
    • AQI (Air quality Index) - range: 0…500
    • Temperature – range: -5…+45 °C
    • Humidity – range: 0…95 % (non-condensing)
  • Cloud Storage: up to 365 days
  • Connectivity: RJ-45 cable connector for Network / PoE powering IEEE 802.3af
  • Receive alerts for offline sensor and device tampering
  • Operating temperature range: -5…+45 °C
  • The Vape Detector FD-VAPE-WALL operates using the TUYA Smart App
  • Connection via WiFi
  • Possibility to pair with TUYA camera and create scene to record when vape alarm triggered
  • Sensors: PM2.5 Laser Scattering, Temperature and Humidity
    • PM2.5 Detection Range: 0-999 µg/m3
    • PM2.5 Response Time: 5 seconds
    • Temperature Detection Range: 0…60 °C
    • Temperature Response Time: 5 seconds
    • Humidity Detection Range: 0 - 100% RH
    • Humidity Response Time: 5 seconds
  • Working Environment: 0…60 °C < 99% RH
  • Power Supply: 5V DC USB (micro USB)

The LoRa-Log-Vape system, using LoRaWAN communication technology, is designed for detecting "vaping" and cigarette smoke. Sensors capture environmental parameters and, upon detecting an event, send a notification to the LoRaWAN receiver (gateway). The data is collected and processed in the receiver and can be viewed on a web page.

The LoRa-Log-Vape registration system consists of a wireless LoRaWAN sensor receiver and wireless Synetica “vape” sensors ENL-IAQ-Vape.

Loading...