This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to DIN 43763 and DIN 43772 (form 4)
  • Lengths: according to customer's specification
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Threads for thermometer: metric M14x1.5, M18x1.5
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Other materials, threads and dimensions
  • Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
  • Ranges: -200...+150°C; -200...+550°C; -200...+600°C
  • Outputs: RTD, 4..20 mA
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
  • Exi RTD sensors for explosive atmospheres with cable
  • Range: -50 .. +400°C
  • Cable insulation: PVC, silicone, teflon, glass fiber
Exi RTD sensors for explosive atmospheres with connection head. Technical specifications Example Model Range Diameter Output XI-TOPGB / XI-APTOPGB -200 .. +150°C Ø9, Ø10, Ø11, Ø12, Ø15 mm RTD, 4..20 mA XI-TOPG / XI-APTOPG -200 .. +550°C Ø11, Ø12, Ø14, Ø15 mm RTD, 4..20 mA XI-TOPT / XI-APTOPT -200 ...
Exi RTD sensors for explosive atmospheres with mineral insulation. Technical specifications Example Model Range Diameter XI-TOPI / XI-APTOPI -200 .. +600°C Ø3, Ø4.5, Ø6, Ø8 mm XI-TRP-BTW -50 .. +600°C Ø1.5, Ø2, Ø3 mm XI-TRP-WL -50 .. +600°C Ø1.5, Ø2, Ø3, Ø4.5, Ø6 mm XI-TRP-TKbW ..
  • Exi thermocouple sensors for explosive atmospheres
  • Range: -40...+1200°C
  • Exi thermocouple sensors for explosive atmospheres with cable
  • Range: -40...+400°C
  • Exi thermocouple sensors for explosive atmospheres with connection head
  • Outputs: TC, 4..20 mA

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU

Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:

  • Periodic measurement of solid state particle concentration in stationary sources of emission
  • Solid state particle concentration measurement in gasses
  • Testing of dust removal equipment
  • Gas flow rate measurement
  • Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
  • Dioxins, furans, PAH, mercury concentration measurement
  • Heavy meal, HCL, HF concentration measurement

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

idOil sensors are an integral part of the idOil oil separator alarm system and they are to be used with the idOil control units. All idOil sensors are digital and polarity free. Standard cable length is 5 m.

 

  • idOil-LIQ high liquid level sensor
    Indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation.
  • idOil-OIL oil sensor
    Detects oil and indicates when the separator’s oil storage is full.
  • idOil-SLU sludge sensor
    Monitors the sludge layer in the oil separator and indicates when the sludge layer has reached its maximum level.

“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:

  • High liquid level (idOil-LIQ high liquid level sensor)
  • Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
  • Sludge layer detection (idOil-SLU sludge sensor)

“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:

  • High liquid level (idOil-LIQ high liquid level sensor)
  • Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
  • Sludge layer detection (idOil-SLU sludge sensor)
  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.

  • Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
  • Nominal input current: 1A or 5A
  • True RMS measurement (up to 15th Harmonic)
  • On site programmable PT/CT ratios
  • User selectable 3ph3wire or 3ph4wire Network (for 3ph)
  • Onsite selection of Auto scroll / Fixed Screen (for 3ph)
  • 4 Digits 14mm ultra bright LED Display
  • Protection: IP54 front / IP20 back
  • Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
  • Accuracy: ±0.5% of nominal value
Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..

The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Distinguishes between vaping and smoke and counts the number of detections
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
  • Power suplly: 12…24V V DC, 0.15 Amp (max)
  • Configuration via USB cable / downlink
  • Operating Temp. / Humidity: 0…40 °C / 0…95 % RH

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)

The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.

  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446

Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).

Multipoint thermocouple temperature sensor TTP-328 is designed for temperature measurement. Suitable for energetics, oil and chemistry industries Every sensor is made out of mineral-insulted cable Process connection is threaded or flanged Compact design Maximum immersion depth is 30 m ATEX design Various variants are possible, depending on client’s request Every sensor can be mounted by up to 24 temperature transmitters. In order to bring the start-up cost down, sensor can be configured by our company. More on TTP-328 multipoint thermocou..
  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
  • 54 electrical network quality parameters
  • Analysis of voltage and current harmonics (up to the 51-st)
  • Color touchscreen: LCD TFT 3.5“, 320 x 240
  • 2 configurable alarm outputs
  • Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
  • Digital output: RS-485 (MODBUS)
  • Ethernet / Profinet 2.2
  • Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
  • Battery backup RTC
  • Dimensions: 96 x 96 x 77 mm
  • Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
  • Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
  • Measuring class A or A / S
  • Support the IEC 60870-5-104 communication protocol (new - option)
  • Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
  • Monitoring up to 6 additional energy meters with pulse output
  • Recording of measurements before and after events (dips & swells)
  • Configurable archives of logged values and events
  • SD card support (up to 32 GB)
  • Webserver function, FTP server, DHCP client
  • Outputs: relays, binary, analog
  • Binary inputs
  • E-mail alarms
  • Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
  • Color touchscreen: LCD TFT 5.6“
  • Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
  • IP65 protection class for front side
  • Real time clock (RTC) synchronization with NPT time server
  • Time synchronization via external GPS module - STR  receiver (new - option)
  • 2 analog outputs (operating simultaneously):
    1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
    2. Voltage 0...10 V.
  • Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
  • 7-segment LED display with adjustable brightness
  • Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
  • Password protection
  • High accuracy and immunity to interference
  • Supply: 230 VAC or 24 VAC/VDC
  • Panel housing 96 x 48 x 79 mm
  • Protection: IP65 (front) / IP20 (back)
RTD sensors TOPE with cable. Technical specifications Example Model Range Protective tube Cable insulation TOPE150 -50 .. +400°C Ø5, Ø6, Ø8, Ø9, Ø10 mm PVC, silicone, teflon, glass fiber TOPE3 -50 .. +400°C Ø5, Ø6, Ø8 mm TOPE4   TOPE310 -50 .. +400°C Ø5, Ø6, Ø8 mm ..
RTD sensors TOP with connection head. Technical specifications Example Model Range Accuracy Tube diameter TOPGB -50…+150°C A class (standard)orB  class according to EN 60751 various variants available TOPGN -200…+600°C TOPG -200…+600°C TOPI -200…+600°C ..
RTD sensors TRP with mineral insulation. Technical specifications Example Model Range Diameter TRP-NA -50 .. +600°C Ø1.5 .. Ø6.0 TRP-BTW -50 .. +600°C Ø1.5 .. Ø3.0 TRP-WL -50 .. +600°C Ø1.5 .. Ø6.0 TRP-TKbW -50 .. +600°C Ø1.5 .. Ø6.0 ..
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists. ..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists.          &n..

For on-line measurements of air pollution or combustion gases flow in chimneys or flues.

Temperature regulator SCD210 is designed for temperature control in various devices and rooms. Made in three variants with different inputs. SCD210 has a step set point (SP) value change by signal option in binary input.

RTD sensors with TOPGDM, TOPGDS connectors. With threaded process connector, designed to measure temperature in pipes, tanks and canals. Measuring range is -50...+400 ºC. Can be fit with a LED display.

The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.

  • Temperature measuring range: 0… +1800 °C
  • Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
  • Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
  • Gastight process connection: (to 0.1 MPa / 1 bar)
  • Optionally the head can be installed with a local temperature display (DANWdie-LED)
  • ATEX and EAC Ex versions
  • For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444

 

 

Thermocouple sensors TTE with cable. Technical specifications Example Model Range Protective tube Cable insulation TTE310 -40 .. +400°C Ø5, Ø6, Ø8 mm PVC, silicone, teflon, glass fiber TTE311 TTE312 TTE409 -40 .. +400°C Ø5, Ø6, Ø8 mm TTE410 TTE411 -4..
Thermocouple sensors TT with connection head. Technical specifications Example Model Range Accuracy Tube* diameter TT_G -40…+800°C 1 class (standard) or 2 according to EN 60584 Various variants available TT_GB -40…+150°C TT_GN -40…+800°C TT_P -40…+800°C ..
Thermocouple sensors TTP with mineral insulation. Technical specifications Example Model Range Diameter TTP-NA -40 .. +1250°C Ø1.0 .. Ø8.0 TTP-BTW -40 .. +1250°C Ø0.25 .. Ø3.0 TTP-WL -40 .. +1250°C Ø1.0 .. Ø6.0  TTP-TKbW -40 .. +1250°C Ø0.25 .. Ø8.0 ..
  • Measurement range: -40…+180 °C
  • Type: J / K / N / T / E
  • Self-adhesive tape
  • Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
  • Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
  • Optional: connector
Thermocouples TTP-320, TTP-321, TTP-322 are suitable for temperature measurement of industrial furnace pipes. Suitable for energetics industry Suitable for oil and chemistry industries Made out of mineral-insulated cable Good vibration resistance Spiral windings for vibration protection Two possible variants, chosen according to client’s request ATEX design Thermocouple TTP-320...TTP-322 description [EN]More on TTP-320...TTP-322 thermocouples on Termoaparatura Wroclaw website [EN] ..
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to PN-79/M-53857/05
  • Threads for thermometer: metric M12x1.5, M14x1.5
  • Lengths: according to customer's specification
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Optional designs per DIN 43772 ( form 4 )
  • Other materials, threads and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
  • Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
  • Dimension tolerance according to DIN ISO 2768
  • Protection tube coated by layer of CrC to increase abrasion resistance
  • Protection tube coated by teflon® PTFE to increase corrosion resistance
  • Other materials, threads, flanges and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming
Loading...