  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years

The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.

  • 64 MEMS digital microphones for image of leaks
  • Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
  • Measuring distance: 3…15 m
  • Integrated visual light camera
  • The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
  • Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
  • Option for IO support through fieldbus coupler
  • Integration: HTTP REST API, Modbus
  • Operating temperature: -20…+50 °C
  • Protection class: IP54
  • Communication and power supply: Ethernet RJ45, POE IEEE 802.3at

The mini-size multimeter has multiple functions, such as auto range, auto scan (SMART) and true RMS functions, which makes it more convenient and intelligent. Besides normal multimeter function, it also has the function of NCV test and LIVE wire test, which is convenient for field testing. Blacklight and Flashlight capabilities facilitate use in dark work environment.

  • CAT III 600V
  • TRMS
  • AC/DC Voltage measurement: 400 mV…400 V
  • AC/DC Current measurement 40 mA … 10 A
  • Resistance measurement 400 mΩ … 40 MΩ
  • Capacitance measurement 4 nF…4 mF
  • Frequency measurement
  • Temperature measurement -200…1200 °C
  • Auto Scan function (SMART)
  • HOLD function, Continuity test and Diode test
  • Dimensions: 130 x 62 x 27 mm
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...10000 ppm
  • Operating temperature: -30...80 °C
  • Cable length: 1 / 2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Duct mount
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Multimeter with backlit LCD screen (two shown values)
  • Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement from 100 μV to 1000 V
  • AC and DC current measurement from 10 μA to 10 A
  • Resistance measurement from 100 mΩ to 60 MΩ
  • Frequency measurement from 10 Hz to 10 MHz
  • Diode measurement and continuity testing
  • Hold function
  • Relative measurement
  • Duty cycle (%) measurement
  • Temperature measurement (K type thermocouple) from 0 to 1300 °C
  • Peak value measurement
  • Digital multimeter with data logging view function (up to 32000 readings) 
  • Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
  • TRMS measurement
  • Low input impedance
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 10 A
  • Resistance measurement
  • Frequency measurement
  • Diode measurement and continuity testing
  • Filtering
  • Square wave signal generator
  • Hold function, backlight, maximal and minimal value presentation
  • External supply
  • Duty cycle (%) measurement
  • Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
  • Automatic / manual range selection
  • USB connectivity (optional)
  • Digital multimeter for insulation resistance measurement
  • Multimeter with backlit LCD screen
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 300 mA
  • Resistance measurement up to 30 mΩ
  • Insulation resistance measurement up to 3 GΩ
  • Capacitance measurement up to 30 μF
  • Frequency measurement up to 100 kHz
  • Fill factor measurement (%)
  • Hold function
  • Temperature measurement (Pt100 and Pt1000)
  • Diode check
  • Analog scale on screen
  • Digital pulse counter - tachometer ECH4400
  • Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
  • Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
  • Control outputs: 2 relay NO / NC 250 V, 2 A
  • SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
  • RS485 Modbus communication interface (custom ordered)
  • Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
  • Auxiliary supply output: 12 VDC, max 50 mA
  • Ambient temperature: 0…+50 °C
  • Case protection: front panel IP65, rear panel IP20

Absolute encoder AC58. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø58, axis - Ø10mm

Incremental encoder RI36. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø36.6 mm, axis - Ø4/6/8/10 mm

Incremental encoder RI38. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø39 mm, axis - Ø6 mm

Incremental encoder RI42. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø40 mm, axis - Ø6 mm

Incremental encoder RI76. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø76 mm, ašis - Ø15...42 mm

Incremental encoder RX70. Vibration- and overload-resistant. Wide range of appliance.

  • Size Ø69mm, axis - Ø10mm
  • Certified for ATEX zone
  • Complies to category II 2 gas and dust
  • IP65/IP66 protection class
  • Certified: II 2 G/D E Ex d II T4/T6 IP65/IP66 135 °C bz. 85 °C

 

  • Universal industrial rotary encoders
  • Up to 40,000 steps
  • High degree of signal accuracy
  • Ingress protection up to IP67
  • Fits most applications due to many flange and connection options
  • Suitable for high shock loads
  • Typical fields of application are machine tools, CNC axes, Packaging machines, Motors/ drives, Injection molding machines, Sawing machines
  • Operating temperature up to 100°C (RI 58-T)

Frequency meters CA32, CA36, CA37, CA39, CA39L are designed for frequency measurement in electrical grid. Transducer signal is measured using magnetoelectric effect. Tropical version available.

  • Frequency range: 45...55, 45...65, 48...52, 55...65, 360...440, 380...420 Hz
  • Voltage range: 60,100, 110, 230, 240, 400, 415, 440, 500 ± 20%
  • Accuracy class: 0,5
  • Consumed power: =< 7 VA
  • Protection class: IP52 or IP65
  • Standards conformed: EN61000-6-2, EN-61000-6-4, EN-61010-1
  • Temperature range: 5...23...40 °C

Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:

  • Periodic measurement of solid state particle concentration in stationary sources of emission
  • Solid state particle concentration measurement in gasses
  • Testing of dust removal equipment
  • Gas flow rate measurement
  • Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
  • Dioxins, furans, PAH, mercury concentration measurement
  • Heavy meal, HCL, HF concentration measurement

Kuhlmann Ground Thawing Blankets are durable and weatherproof, designed to thaw frozen ground and soil, pipes, and protect equipment from freezing. They also work as curing blankets for various construction purposes.

Technical specifications:

  • Durable PVC materials.
  • Fixed temperature (70°C).
  • 2-meter power cable.
  • Special sizes produced upon request.
  • IP67 Class.
  • In normal conditions the mat thaws up to 30 cm of soil in 24 hours - or up to 60 cm in more sandy soil/ground.

Incremental encoder RI32-O (Hengstler, Germany) is resistant to vibration and overloading, has a wide area of application.

  • Size Ø30 mm, axis – Ø5 or Ø6 mm

 

Digital programmable indicator N20Z for AC voltage, current and frequency measurement.

 

Programmable parameters:

  • LED indicator color, which changes depending on input signal value: green, yellow and red
  • Value limits
  • Measurement unit indication
  • Decimal point location
  • Measured signal
  • Averaging time
  • Individual characteristic
  • 2 OC alarms in 6 modes
  • Digital, programmable pulse, frequency, motor revolutions, work time meter N30O with RS-485 interface
  • Programmable with keys or via computer
  • Digital, programmable power network parameter meter N30P with RS-485 interface
  • Measures voltage, current, frequency, active, reactive power, cosφ, tgφ, energy consumption
  • Programmable with keys or via computer
  • Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
  • Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
  • Up to six gas sensors
  • CO measurement up to 50 000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Magnetic measurement (contactless, non-friction system)
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP67
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Portable reference point
  • Stroke values up to 2000 mm
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP65

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

The enLink Status-P transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 3 channels pulse counter (S0 standard) and monitor of state (open / closed)
  • With the transmit on Change of State enabled the unit operates as a standard pulse counter and also transmits a message when the state of the input changes from closed to open or open to closed
  • The pulse counts for each channel are written to memory every 5 – 10 minutes
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by change of state)
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)
  • The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
  • Long range and high sensitivity internal (or external mounted) antennas
  • To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
  • The gateway firmware can be upgraded remotely using MQTT
  • B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
  • Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
  • Possible to activate 128 bit AES-key encryption
  • Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
  • IoT LTE M SIM card needed (acquired separately)

Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).

Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).

  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C

Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.

The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.

  • Oxygen concentration measuring in air and inert gas mixtures
  • Specially developed for use in composting plants
  • Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
  • Value indicator of measured oxygen concentration
  • Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
  • Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
  • Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
  • Material of protective tube: Stainless steel 1.4301
  • Housing ambient temperature: -10…+50 °C
  • Probe ambient temperature: -10…+100 °C
  • Protection class of housing electronic: IP65
  • Protection class of probe: IP40
  • Rechargeable battery with indication of voltage
  • It is possible to connect the sensor to a stationary data processing system
  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
  • 54 electrical network quality parameters
  • Analysis of voltage and current harmonics (up to the 51-st)
  • Color touchscreen: LCD TFT 3.5“, 320 x 240
  • 2 configurable alarm outputs
  • Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
  • Digital output: RS-485 (MODBUS)
  • Ethernet / Profinet 2.2
  • Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
  • Battery backup RTC
  • Dimensions: 96 x 96 x 77 mm
  • Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
  • Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
  • Measuring class A or A / S
  • Support the IEC 60870-5-104 communication protocol (new - option)
  • Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
  • Monitoring up to 6 additional energy meters with pulse output
  • Recording of measurements before and after events (dips & swells)
  • Configurable archives of logged values and events
  • SD card support (up to 32 GB)
  • Webserver function, FTP server, DHCP client
  • Outputs: relays, binary, analog
  • Binary inputs
  • E-mail alarms
  • Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
  • Color touchscreen: LCD TFT 5.6“
  • Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
  • IP65 protection class for front side
  • Real time clock (RTC) synchronization with NPT time server
  • Time synchronization via external GPS module - STR  receiver (new - option)

Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.

The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.

  • Two-color LED display
  • Backlit units of all measured quantities
  • Configurable analog and alarm outputs
  • Digital RS-485 interface, MODBUS
  • Archiving data in the internal memory file system memory 8 GB
  • Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
  • services: www server, ftp server, DHCP client
Loading...