Temperature and standard signal transducer P30U.
- Programmable input
- Mathematical functions
- Individual channel characteristic
- 1 or 2 outputs
- Variant with internal transducer 24 VDC power supply
- RS-485 interface
- Adjustable dimension
- Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
- Transducer programming with buttons or via PC (“LPConfig” software)
- Two set points
- Input: TC (J, K, T, R, S) / RTD (Pt100)
- Control output: relay or SSR
- Auxiliary output: relay
- PID / ON-OFF control
- Auto-Tuning / Self-Tuning
- Alarm modes: deviation, absolute
- Heating / cooling control
- 4+4 digits high contrast LED display
- Supply: 85…270V AC / DC
- Ambient temperature: 0…50 °C
- Inputs: Pt100, thermocouples J, K
- 4-digit 20 mm LED screen
- Automatic or manual compensation
- Programmable input, decimal point, averaging time
- 24 VDC output for external transducers
- Galvanic isolation
- Supply: 230 VAC / 240 VAC / 20...40 VAC / 20...40 VDC
- Protection class: IP65
- Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
- Universal input for thermocouples and resistance thermometers
- Relay output for disconnecting the temperature control system
- Supply: 230 VAC
- Operating temperature: 0...50 °C
- Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
- PID or ON/OFF control
- Automatic selection of PID parameters
- One relay output and one alarm relay
- Manual control mode
- One binary input
- Operating temperature: 0...50 °C
- Supply: 230 VAC
- Protection class: front IP65, back IP20
- Three-color numerical display DL21 is designed to indicate various parameters (temperature, humidity, etc.) from external devices via RS-485
- Can be used in offices, industrial and communal buildings
- Indicator color is programmable (green, red and yellow)
- Programming is done via RS-485 port
- Can work in master and slave modes
- Transducer for AC current and voltage into DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input
- Transducer for DC current and voltage into other DC signal (2 outputs)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
- This enables to increase device number in the system and extend its range
- Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
- Input is isolated from input and supply
- Has fixed inputs and outputs – non-programmable
- Up to 10 / 15 m level measurement with automatic temperature compensation
- Calculation of filling in the tank or flow in open channels
- Galvanically isolated 0/4...20 mA analog output
- Digital RS-485 Modbus RTU interface
- 2 alarm outputs
- Internal data and setup memory
- Two 32-points individual characteristics (for recalculation)
- LCD screen
- Housing protection grade: IP66
- Sensor protection grade: IP66 / IP 68
- Supply: 12...25...40 VDC
- Operating temperature: -20...23...55 °C
- Up to 10 / 15 m level measurement
- Analog output: 4…20 mA
- Digital output: RS-485 Modbus RTU
- Resolution: 3 mm
- Supply: 24 VDC / 300 mA
- Operating temperature: -20...60 °C
- Cable length: 1 m
- Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
- Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
- Universal input for RTDs, thermocouples and analog signals
- Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
- The controller has three alarms, which can be assigned to each output
- The output signals are galvanic isolated from the input signals and power supply
- Selection of PID parameters for any unit, or auto-tuning
- Protection class from frontal side: IP30, from terminal side: IP20
The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).
Main features:
- Sampling rate (5 times / second)
- 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
- 2 input: 0 / 4…20 mA and 0…10 V
- Binary input for changing the function of the controller and SP switching
- Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
- Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
- Programmable digital filter
- Hardware and software security before changing settings
- Alarm for breaking the control loop
- Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
- Protection class: IP65
The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.
- Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
- Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
- Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
- Profile Controller: Up to 128 steps
- Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
- Communication: RS485 MODBUS RTU
- Power Supply: 90...270 VAC / DC (50/60Hz)
- Display: 4+4 digit, 7 segments
- Ambient temperature / humidity: 0…+50 °C / < 85%RH
- Dimensions: 52 x 52 x 76 mm
- In PD24 converter are used 2 interfaces (USB, RS232) - galvanically isolated
- USB interface (type A) – destined for the device communication with the computer
- RS-232 interface - destined for the communication with devices from the object side
- PD24 is programmer of LUMEL products to configure settings using eCon software
- Compliance with the standard USB 1.1 and USB 2.0
- Data transmission rate up to 115.2 kbps
- Support virtual serial port (COM)
- Device supplied from USB port and from the RS-232 (TTL) side
- Set includes 1,5 m data transmission cable with RJ12 plugs to configure LUMEL products
- External dimension: 62 x 25 x 20 mm
- In PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated
- USB interface (type A) – destined for the device communication with the computer
- RS-485 interface - destined for the communication with devices from the object side
- Compliance with the standard USB 1.1 and USB 2.0
- Data transmission rate up to 115.2 kbps
- Support virtual serial port (COM)
- Bi-directional data transmission (half duplex)
- Device supplied from USB port
- External dimension: 76 x 25 x 20mm
- Converter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols
- The program is designed to represent and log measured values
- Representation tools: bar graphs, graphs, numbers
- Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
- Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
- Data logging: tables and/or graphs in PC memory
- Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Display: 3-color LED, 5-digit
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
- Protection class: IP65
- Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Display: 3-color LED, 5-digit
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
- Protection class: IP65
- Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
- Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
- Current measurement range: 0/4...20 mA; ±20 mA (DC)
- Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Auxiliary 24 VDC output to supply transducers
- Display: 3-color LED, 5-digit
- Temperature compensation
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
- Protection class: IP65
The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.
Applications: Motor protection, Server rooms, Control system
Features:
- Compact size 17.5 mm
- True RMS measurement
- Under voltage protection
- Over voltage protection
- Phase unbalance protection
- Phase failure protection
- Phase incorrect sequence protection
- Neutral failure protection
- Adjustable Nominal voltage, Trip point, Trip time delay
- Onsite selection of VLL / VLN value-based tripping
- Self-powered
- 1CO, 1CO+1CO relay configuration
- LED indication for faults
- Disabling of Over & Under Voltage fault on site is possible
- Voltmeters for AC voltage measurement EP27, EP29 with a change-over switch
- Panel electromagnetic devices, designed for effective voltage measurement
- Change-over switch, when activated, enable the measurement of linear and phase voltage (6 measurement points)
- Tropical version is available (TIII)
- Voltmeters for usage with voltage transformers (X/100 V and X/110 V) are also available
