This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
    • Modes: C1-A/B, T1 or S1 (selectable on order)
  • Measurement ranges
    • Temperature: -40…85 °C
    • Humidity: 0…100 % RH (non-condensing)
    • CO2: 0…5000 ppm (0…55 °C)
    • LUX: 0,01…83000 LUX at same frequency as the human eye
    • Absolute pressure: 20…100 kPa
    • Sound level: 20…90 dBa at 850 Hz
  • Measurement accuracy
    • Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
    • Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
    • CO2: ± (50 ppm + 3%)
    • LUX: 4 %
    • Pressure:  0,4 kPa
  • CO2 sensor calibrates every 20 days
  • Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
  • Transmission interval: every 90 seconds
  • Measured values sample interval: every 6 minutes
  • LED and sound indication about CO2 exceeded limit
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Up to 14 years battery lifetime, standard configuration and operating temperature
  • The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
  • Long range and high sensitivity internal (or external mounted) antennas
  • To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
  • The gateway firmware can be upgraded remotely using MQTT
  • B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
  • Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
  • Possible to activate 128 bit AES-key encryption
  • Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
  • IoT LTE M SIM card needed (acquired separately)
  • MA series converters reads Wired M-Bus meters and transmit the data wirelessly using the Wireless M-Bus protocol
  • Reads data from up to 500 devices
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: T1
  • AES-128 encryption mode 5, profile A
  • Automatically search wired meters and sends data
  • Two internal antennas or one external antenna
  • Power supply: 100…240 VAC
  • Protection class: IP67
  • Device G2-DC designed to monitor state of relays or reed switches
  • Input: 2 dry contacts
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S (selectable on order)
    • Standard T1-mode, transmission 90 seconds, encryption ON
  • Transmission interval: configurable 60 s…1 h (selectable on order)
  • Every message contains the contact status and battery level
  • The message is sent as soon as a dry contact switch is detected
  • AES-128 encryption mode 5, profile A (can be ordered with custom configuration)
  • Power supply: 3.6V Li-SOCl2, AA battery
    • Warning about low battery
    • Up to 14 years battery lifetime, depending on configuration and operating temperature
  • Operating temperature: -30…+85 °C (Recommended: +5…50 °C) (none condensing)
  • G2-P pulse counter converts wired consumption meter into a wireless meter
  • Types of devices: water, electricity, HCA, room sensor devices, etc.
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: configurable C, T, or S
    • AES-128 encryption mode 5, profile A
  • Value format: 0,001...10000 / pulse (configurable). Unconverted dimensionless value
  • The total number of pulses is sent periodically
  • It is possible to count pulses from two devices simultaneously
  • Pulses from the electricity meter LEDs can also be counted using an optical probe (only one optical probe can be mounted)
  • Transmission interval: configurable 60 s…1 hour
  • Tamper protection
  • Operating temperature: -30…+85 °C none condensing (recommended +5…+50 °C)
  • Power supply: AA battery 3.6 V Li-SOCI2
    • Battery lifetime up to 14 years, depends on configuration and operating temperature
  • Range Extender increases the receiving range of the wM-BUS gateway up to 2x or more
  • Filters out interferences such as 4G, LTE, TV and WLAN
  • Communication: wM-BUS protocol EN13757-3/4:2013
    • Modes: S1, C1 and T1
  • Complies with the OMS standard
  • Only receive signals (Rx)
  • Connected between antenna and gateway using standard SMA connector
  • Mountable on DIN rail
  • Power supply: 12…24 V AC / DC
  • Working temperature: -40…85 °C
  • R4 series repeaters have multihop routing function (up to 4 repeaters connected in serial)
    • uR (microreapeater) – only retransmits data of sensors to repeater
  • Communication: Wireless M-BUS (868MHz) EN 13757-3/4:2013
    • Modes: T, C and S
  • Complies with the OMS standard, OMS 4.0.2
  • Support up to two external antennas or one vertical and one horizontal internal antenna (depending on model)
  • Supports routing of Security profile A and B according to OMS 4
  • Ability to forward messages of 932 devices
    • uR (microreapeater) - forward messages of 100 devices
  • Flexible time settings of data collection and transmission
  • Enclosure protection (selectable):IP40 (indoor) or IP65 / IP67 (outdoor)
  • Battery lifetime: 10+ years (depending on the configuration)
  • Power supply
    • Internal battery: 3.6 V Li-SOCI2
    • Mains: 100-240 V AC
    • 24 V AC / DC (on request)
  • Operating temperature: -35…+85 °C
  • Sensor C-TH measures ambient temperature and humidity
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S*
  • Measurement ranges
    • Temperature: -40…+85 °C
    • Humidity: 20…80 % RH (non condensing)
  • Measurement accuracy
    • Temperature: ± 0,2 °C in the range of 0…65 °C
    • Humidity: ± 2 % RH in the range of 20…80 %
  • Transmission interval: 60 s…1 hour*
  • AES-128 encryption mode 5, profile A, custom KEY
  • Power supply: ER14505 3.6V Li-SOCl2 battery (soldered)
    • 14 years expected, standard configuration and operating temperature
  • Sensor CX-TH measures ambient temperature and humidity
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S *
  • Measurement ranges
    • Temperature: -40…+85 °C
    • Humidity: 20…80 % RH (non condensing)
  • Measurement accuracy
    • Temperature: ± 0,2 °C in the range of 0…65 °C
    • Humidity: ± 2 % RH in the range of 20…80 %
  • Transmission interval: 60 s…1 hour*
  • AES-128 encryption mode 5, profile A, custom KEY
  • Power supply: ER14505 3.6V Li-SOCl2 battery (soldered or optional battery holder)*
    • 14 years expected, standard configuration and operating temperature
  • Operating temperature: 0...+55 °C
  • * - T1-mode, 150 seconds, Encryption ON, unique key (individual options should be stated before order)
  • Sensor O-TH designed to measure temperature and humidity in outdoor
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S (selectable on order)
    • Standard T1-mode, transmission 90 seconds, encryption ON
    • AES-128 encryption mode 5, profile A (can be ordered with custom configuration)
  • Measurement range
    • Temperature: -40…+85 °C
    • Humidity: 0…100 % RH (none condensing)
  • Accuracy
    • Temperature: ± 0,2 at 0..+85 °C and ± 0,3 at -40…+85 °C
    • Humidity: ± 2 %RH
  • Transmission interval: custom ordered 60 s…1 h (standard 90 s)
  • AES-128 encryption mode 5, profile A (can be ordered with custom configuration)
  • Power supply: 3.6 V Li-SOCI2, ER17505 battery
    • Warning about low battery
    • Battery lifetime up to 16 with standard configuration and operating temperature
  • Operating temperature: -30…+85 °C (Recommended: -20…+50 °C)
  • Sensor O-T-H designed to measure temperature in harsh environment
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S (selectable on order)
    • Standard T1-mode, transmission 90 seconds, encryption ON
    • AES-128 encryption mode 5, profile A
  • Measurement range
    • Temperature: -40…+85 °C
  • Accuracy
    • Temperature: ± 0,2 at 0..+85 °C and ± 0,3 at -40…+85 °C
  • Transmission interval: custom ordered 60 s…1 h
  • Power supply: ER17505 3.6V Li-SOCl2, battery
    • Warning about low battery
    • Battery lifetime up to 14 years, depending on configuration and operating temperature
  • Operating temperature: -35…+85 °C (Recommended: -30…+50 °C)
  • Sensor O-EXT measures temperature with external probes in outdoor (IP66-casing)
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: custom ordered C, T, or S (standard T-mode)
  • Measurement range: -40…+125 °C
    • Accuracy: ± 0,5 °C
  • Up to 4 external 1-wire probes can be connected
  • Transmission interval: custom ordered 300 s…1 h (standard 5 min)
  • AES-128 encryption mode 5, profile A (key unique to each device)
  • Power supply: battery 3.6 V Li-SOCI2
    • Continuous battery level monitoring
    • Battery lifetime up to 16 years at 25 °C with standard configuration
  • Operating temperature: -40…85 °C
  • Sensor G2-EXT measures temperature with external probes
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S (configuration on order)
    • AES-128 encryption mode 5, profile A (configuration on order ON / OFF)
    • Standard: T1-Mode, 5 min.Encryption ON
  • Measurement range: -55…+125 °C
    • Accuracy: ± 0,5 °C
  • Up to 4 external 1-wire DS18B20+ probes can be connected
  • Warnings about low battery, case opened or removed from wall (opt.) or sensor not working
  • Transmission interval: configurable 60 s…1 hour
  • Operating temperature: -30…85 °C (recommended: +5…+50 °C) (non condensing)
  • Power supply: ER14505 battery 3.6 V Li-SOCI2
    • Battery lifetime up to 14 years, depends on configuration and operating temperature
  • Sensor E2-VOC measures VOC (Volatile organic compounds), ambient temperature and humidity, transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: T (C or S can be custom ordered)
    • AES-128 encryption mode 5, profile A
  • Measurement range
    • Temperature: -40…+85 °C
    • Humidity: 0…100 % RH (non condensing)
    • VOC: 0…60000 ppb
  • Measurement accuracy
    • Temperature: ± 0,2 °C in the range of +5…+55 °C
    • Humidity: ± 2 % RH in the range of 10…90 %
    • VOC: typical ± (15…25 %) of value at 25 °C / 50 % RH
  • Transmission interval: 90 s both sampling and sending. Custom sending interval on request (60 s…1 hr)
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Battery lifetime up to 14 years, depends on configuration and operating temperature
  • Water leakage detector G2-LD detects leakage with active 1 meter cable
  • Up to 2 leakage cables mountable
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: configurable C, T, or S (configurable)
    • AES-128 encryption mode 5, profile A
  • Transmission interval: configurable 60 s…1 hour
  • Operating temperature: -30…+85 °C (recommended +5…+50 °C) (None condensing)
  • Warnings about low battery, case opened or removed from wall (opt.), leakage detected (red LED)
  • Power supply: ER14505 3.6 V Li-SOCI2 battery
    • Battery lifetime up to 14 years, depends on configuration and operating temperature
Loading...