This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:

The CM22 provides essential video security features in a compact form. It is a 3MP (2048x1536) camera with 10 meters of IR light range, and includes people and vehicle detection for motion search and trajectory analysis. The CM22 camera, combined with the SV23 vape detector and air quality sensor, and powered by the Verkada Command cloud computing platform, creates a powerful vape prevention and logging system.

  • 30, 60 and 90 days of data retention (256…768 GB) on hardware and cloud back-up. If the connection to the Command cloud is lost, data is saved onboard and synced once the internet connection is restored
  • Easy to install: no NVR, DVR, servers or port forwarding, just PoE connection
  • Alerts: Camera status (offline), motion detection, people detection, vehicle detection, crowd detection, line-crossing detection, loitering detection
  • Privacy: live face blur, privacy regions and audit log
  • Field of view: Horizontal: 95°; Vertical: 69°; Diagonal: 130°
  • Operating temperature / humidity: -10…50 °C / 0…90 %
  • Connection and power input: RJ-45, PoE (IEEE 802.3af type 1)
  • Certifications: FCC, ICES, RCM, VCCI, CE, UKCA, EN 50155 railway compliance, UL/cUL/IEC 62368-1, NOM
  • Warranty: 5 years
  • Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
  • Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
  • Up to six gas sensors
  • CO measurement up to 50 000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

Analog laser light barriers and their electronic control units. Round or rectangular cross-sections are used for measuring, positioning or detection of objects starting from 0,01 mm (i.e. threads) from great distance (up to 100 m, depending on model).

These sensors should be used where high positioning accuracy is required.

C-LAS compact laser light barriers are ideally suited for positioning tasks.

Laser digital light barriers D-LAS operate by using parallel visible laser light. These light barriers are ideal for positioning tasks.

Laser fork light barriers F-LAS for complex problems. These light barriers are ideal for positioning tasks.

Fork light barriers of the FIA series primarily are chosen for high-precision trigger applications. They are frequently used in the stamping industry. Because of their compact and very sturdy design they are generally used in rough industry environments.

Laser miniature light barriers M-LAS have very small dimensions and work at distance up to 2 m. These light barriers are ideal for positioning and small object detection tasks.

An integrated polarization filter ensures protection against spurious triggering caused by reflecting objects.

  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Magnetic measurement (contactless, non-friction system)
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP67
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Portable reference point
  • Stroke values up to 2000 mm
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP65

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC
  • The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
  • Long range and high sensitivity internal (or external mounted) antennas
  • To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
  • The gateway firmware can be upgraded remotely using MQTT
  • B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
  • Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
  • Possible to activate 128 bit AES-key encryption
  • Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
  • IoT LTE M SIM card needed (acquired separately)
  • The system is designed to monitor pressure and flow rate of medical gasses
  • Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
  • SCADA software enables the visualization of the process
  • Data is logged annd represented on the computer screen
  • Values can also be represented in graphs
  • Moisture reading range:
    • 4…18 % for Lint cotton
    • 6…20 % for Seed cotton
    • 12…30 % for Wool
    • 6…25 % Viscose / Rayon
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app. timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7.24 x 4.06 cm
  • Weight: meter only: 218 gr
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • Hay: 6…40 %
    • Hops: 8…23 % (FX-30)
    • Hemp: 7…34 % (FX-30)
    • Tobacco: 8…37 % (FX-30)
    • Brazil Nuts: 6…25 % (FX-30)
    • Dates: 6…25 % (FX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (FX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app FX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7,24 x 4,06 cm
  • Weight: meter only: 218 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • 4,3…18 % moisture for paper (kraft paper calibration)
    • 5…40 % for baled scrap paper (PX-30)
    • 0…100 reference scale for obtaining relative moisture levels on other materials without calibration (PX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (PX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app PX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 21.97 x 7.24 x 4.06 cm
  • Weight: meter only: 218 / 244 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.

  • 30 - 365 days (1TB - 8TB) of onboard storage
  • Redundant cloud backup and unlimited cloud-based archiving of footage
  • Sensor Resolution: 4 x 5MP (2688 x 1944)
  • Protection class / Impact rating: IP66 / IK10
  • Operating temperature: -40…+50 °C
  • Warranty: 10 Years
  • Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant

The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.

  • The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
  • The data is gathered from various measuring devices and conveyed into a PLC
  • PLC and SCADA interface is MODBUS TCP
  • Manual and automatic control is available
  • Marameters can be changed via SCADA (IGSS) software
  • All data is logged
  • Oxygen concentration measuring in air and inert gas mixtures
  • Specially developed for use in composting plants
  • Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
  • Value indicator of measured oxygen concentration
  • Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
  • Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
  • Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
  • Material of protective tube: Stainless steel 1.4301
  • Housing ambient temperature: -10…+50 °C
  • Probe ambient temperature: -10…+100 °C
  • Protection class of housing electronic: IP65
  • Protection class of probe: IP40
  • Rechargeable battery with indication of voltage
  • It is possible to connect the sensor to a stationary data processing system

LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Additional 2 pages for harmonics presentation and 1 dedicated page for visualization in the form of an analog meter
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Optional: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, WWW server, FTP server, DHCP client

Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems

  • High accuracy class (0.2S for active energy)
  • Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
  • Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
  • Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
  • Memory of minimum and maximum values
  • 2 configurable alarm outputs
  • Supervisory relay mode for alarm outputs
  • Password protection
  • Programming of parameters using free eCon software
  • Battery backup RTC
  • Supply: 85...253 V ac / 90...300 V dc
  • Operating temperature: -10…23…+55 °C
  • Overall dimensions: 96 x 96 x 77 mm

The small sensor dimension combined with IO-Link, the pressure and temperature value of the media make the NAI 8273 the ideal choice in various applications.

  • Measuring range: -0.2...0.2 to 0...700 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN
  • Accuracy at 25°C typically: ± 0.3 % FS typ., ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –40... +125 °C
  • Ambient temperature: –40...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology
  • Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
  • Plinth or foundation for fixing the cabinet.
  • PLC controller with a display that changes the backlight depending on operating mode.
  • Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
  • Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Data visualization in WWW server
  • Convenient login from various devices (PC, tablet, phone)
  • Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
  • 8 GB Flash memory
  • Real time clock (RTC)
  • 2 alarm outputs or 2 binary inputs
  • RS-232, RS-485, USB, Ethernet
  • TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
  • User-friendly WEB interface for easy configuration and control
  • Free version let monitor up to 10 items
  • The monitored parameters can be sensors, digital and analog inputs and relay outputs
  • Graphical and Data dashboards for better visualization
  • TC Monitor allows flexible administration of user accounts
  • Easy access to the raw data tables, export in .csv format
  • Alarm notifications
  • User activities log

The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.

  • Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
  • Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
  • Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
  • Configuration the parameters via the WEB server
  • RS232 port for RTS/CTS signals
  • Hardware Watchdog, Heartbeat
  • Electrostatic protection 15 / 8 kV
  • Power supply: 5…36 V dc
  • Modern SCADA system
  • Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
  • Free license supports only one chosen driver (i.e. Modbus)
  • Hardware-independent, communicates with all major industry-standard
  • Mobile application (in full version)
  • 25 year experience in the marketplace  - developed by 7-Technologies which belongs to Schneider Electric
Fluid level electrode ASTA 460 MM4.  Electrode length 460 mm Electrode material Stainless steel (AISI 304) Thread M4  More information on electrode extension ASTA 460 MM4 on Lovato website [EN] ..
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications Sensor:  NDIR, 2 Measuring range: 0 ... 1000 ppm ..

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C
  • Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
  • Device settings
  • Data download
  • Analysis of critical situations
  • Presentation of measured data
  • Reports
  • Database import/export
  • Free license
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists. ..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists.          &n..
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
Loading...