Digital programmable indicator N30B with data logging function and RS-485 interface.

 

  • LED indicator colors: red, green, yellow (for 3 input value ranges)
  • Internal memory (up to 350064 records)
  • Memory expansion up to 4 GB using a MMC/SC memory card
  • RTC (real time clock) – with automatic time change
  • Autonomic supply
  • Digital, programmable pulse, frequency, motor revolutions, work time meter N30O with RS-485 interface
  • Programmable with keys or via computer
  • Digital, programmable power network parameter meter N30P with RS-485 interface
  • Measures voltage, current, frequency, active, reactive power, cosφ, tgφ, energy consumption
  • Programmable with keys or via computer
  • Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
  • Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
  • Programmable input:
    • Current: 0…1 / 0…5A
    • Voltage: 0…100V / 0…230V / 0…400V
  • Output:
    • Analog: 0/4...20 mA or 0...10 V
    • Relays: 1 or 4
    • Binary (OC)
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Two-line LCD display
  • Pulse output to measure energy consumption
  • 4 alarm outputs with signaling on LED diodes, working in 7 different modes
  • Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C
  • Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
  • 4 alarm outputs with signaling on led diodes, working in 7 different modes
  • Analog outputs: 0/4...20 mA or 0...10 V
  • Digital output: RS-485 / MODBUS RTU
  • Two-line LCD display
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.

  • Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
  • Nominal input current: 1A or 5A
  • True RMS measurement (up to 15th Harmonic)
  • On site programmable PT/CT ratios
  • User selectable 3ph3wire or 3ph4wire Network (for 3ph)
  • Onsite selection of Auto scroll / Fixed Screen (for 3ph)
  • 4 Digits 14mm ultra bright LED Display
  • Protection: IP54 front / IP20 back
  • Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
  • Accuracy: ±0.5% of nominal value

Indoor temperature meter / transducer Txx18, designed for temperature, humidity and barometric pressure measurement.

Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations

  • Web-based configuration and control with password protection
  • 4 digital inputs for dry contacts
  • 4 analog inputs with 0-10V and 0-20mA options
  • 4 relays with normally open/normally closed contacts
  • RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
  • Monitor up to 24 channels
  • Set up to 24 independent alarms
  • SNMPv3 protocol support
  • Alarm notifications via SNMP traps
  • NTP protocol support
  • HTTP API commands
  • 4 schedules for real-time control of relay outputs
  • Custom logical functions
  • Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
  • Data logging capacity for up to 70,000 records
  • Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
  • Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
  • MODBUS TCP / IP protocol support
  • MQTT 3.1.1 protocol support
  • Rugged DIN-Rail / wall-mountable enclosure
  • Operating temperature range: -20…+55 °C
  • For galvanic separation of current signal between explosive (Ex) and normal areas
  • Input: 0...20 mA, 4...20 mA
  • Output: 0...20 mA, 4...20 mA, version with 0...10 V
  • Version with support for HART signal
  • DIN rail-mounted
  • Supply: 24 VDC / 230 VAC
  • Operating temperature: -20...60 °C
  • Protection class: IP20

The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal to find even smallest leakages (0.1 l/min) easily even in far distances and calculate potential saving (€/year).

  • 30 MEMS digital microphones for image of leaks
  • Measuring distance: up to 6,5 m
  • 3,5” TFT color display with touch panel
  • Additional sensor input to measure: dew point, flow, pressure, and temperature (LD 510 only. See datasheet)
  • Possibility to take photo of leaking parts
  • Data transfer via USB to PC
  • Easy data and work assignment with CS Leak Reporter cloud solution
  • ISO 50001 report
  • Power supply: 7,2 V lithium-ion battery (> 9 h continuous operation)
  • Operating temperature: -5…+40 °C
  • For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls
  • Output: switch or PNP
  • Sensitivity setting by means of magnetic pen
  • LED indication
  • Prismatic or planar electrode
  • Versions with a fixed cable or a connector
  • Supply: 6...30 VDC
  • Operating temperature: -20...+80 °C
  • Protection class: IP67

The Wx9xx series of sensors from COMET SYSTEM enables accurate measurement of temperature, relative humidity, and atmospheric pressure, with data transmitted via the low-power LoRaWAN network. This technology allows data to be sent to a cloud storage, where users can easily view both current and historical values through a standard web browser. Each sensor has an LCD display showing the measured value and battery status.

  • Possibility to connect Pt1000 sensors
  • Covers up to 15 km in rural areas and 2…5 km in urban areas
  • Work with Comet System LoRaWAN gateway SP041
  • Battery life: from 1 to 10 years depending on transmission time and environment temperature
  • Unlimited space for data in cloud
  • Alarm: email and app notification
  • Mobile applications for Android and iOS
Non-reversible temperature labels, 10 temperature ranges.  A °F°C 10440  10842 11144 11546 12049 12954 14060 14462 14965 16071  B °F°C  17177 18082 19088 19993 21099 ..
  • Input: Modbus RTU – RS-485
  • Output: 4-channel SPST relay contacts
  • Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
  • Non-volatile memory to retain and restore relay states following power outages
  • Watchdog functionality for communication loss
  • Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Moisture reading range:
    • 4…18 % for Lint cotton
    • 6…20 % for Seed cotton
    • 12…30 % for Wool
    • 6…25 % Viscose / Rayon
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app. timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7.24 x 4.06 cm
  • Weight: meter only: 218 gr
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • Hay: 6…40 %
    • Hops: 8…23 % (FX-30)
    • Hemp: 7…34 % (FX-30)
    • Tobacco: 8…37 % (FX-30)
    • Brazil Nuts: 6…25 % (FX-30)
    • Dates: 6…25 % (FX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (FX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app FX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7,24 x 4,06 cm
  • Weight: meter only: 218 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • 4,3…18 % moisture for paper (kraft paper calibration)
    • 5…40 % for baled scrap paper (PX-30)
    • 0…100 reference scale for obtaining relative moisture levels on other materials without calibration (PX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (PX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app PX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 21.97 x 7.24 x 4.06 cm
  • Weight: meter only: 218 / 244 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
  • Temperature sensor: HQ digital temperature/ relative humidity internal or optional external sensor
  • Temperature measurement range: -30...+70 °C (-40...+90 °C with ext T sensor) (-80...+200 °C with ext Pt100 sensor)
  • Temperature accuracy: ±0.3 °C (-20...+40 °C); ±0.5 °C
  • Humidity measurement range: 0...100 % rH
  • Humidity accuracy: ± 3 % rH (20...80 %), 5 % kitur (25 °C)
  • Memory: 60,000 values ​​(up to 6 months)
  • Display: multifunction LCD
  • Protection class: IP65
  • Automatic PDF, CSV reporting: Yes
  • Connection interface: USB 2.0, A-Type
  • Measured parameters (with respective sensors):
    a) Temperature (Pt100 or thermocouple)
    b) Humidity
    c) Air quality
    d) Air velocity
    e) Airflow
    f) Tachometry
  • Two inputs for Pt100 temperature sensors (range -200...600 °C)
  • Up to 6 measurements simultaneously
  • Power supply: Lithium-Ion battery (up to 57 hours)
  • Calibration certificate, additional battery, transport case included
  • Operating temperature: 0...50 °C
  • Protection class: IP54

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20
  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C
  • Supplies and controls NAMUR sensors (1 or 2 channels)
  • Relay or transistor output
  • Output voltage: 9,2 VDC
  • High frequency switching (up to 2 kHz)
  • DIN rail-mounted
  • LED indication
  • Supply: 24 VDC / 230 VAC
  • Operating temperature: -20...60 °C
  • Protection class: IP20
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

The unit is designed for determining dielectric loss tangent and permittivity of transformer oils and other dielectric fluids according to the IEC 60247.

It is a fully automatic device that allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu.

  • Applied measuring voltage: 500…2000 V a.c. sinusoidal
  • Tan δ measurement range: 0,00001…1
  • Tan δ measurement resolution: 1х10-5
  • Tan δ measurement accuracy: ± 1 % of measurement + 0,00008
  • Measurement range of relative dielectric constant ε: 1,0…15,0
  • Accuracy of ε measurement: ± 1 %
  • Oil temperature measurement range: 20…110 ᴼС
  • Measuring cell volume: 42 cm³
  • Power supply: 85...264 V a.c. (48…63 Hz)

Applications:

Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
    • at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019

Applications:

surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line) ≤ 55 V
    • at In, C2 (8/20 μs, line-PG) ≤ 500 V
    • at C3, 1 kV/µs (line-line) ≤ 48 V
    • at C3, 1 kV/µs (line-PG) ≤ 600 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019

Applications:

  • For protecting low voltage equipment against lightning and surge damages
  • For installation in conformity with the lightning protection zones concept at LPZ 0-1
  • Designed according to IEC 61643-11:2011

 

Specifications:

  • Category IEC / EN / VDE: class II+III / type 2+3 / C+D
  • Max. continuous operating voltage Uc 275 V AC
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • Voltage protection level Up ≤ 1,5 kV
  • Max. backup fuse 125 A

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T4611, T3611, T7611. Only to be used with external sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T0610, T3610, T7610. Only to be used with internal sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units

Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.

The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.

  • Two-color LED display
  • Backlit units of all measured quantities
  • Configurable analog and alarm outputs
  • Digital RS-485 interface, MODBUS
  • Archiving data in the internal memory file system memory 8 GB
  • Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
  • services: www server, ftp server, DHCP client
  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54
  • Radar level meter GRLM-70 for continuous level measurement in liquids, mush and bulk-solid materials
  • Outputs: 4...20 mA HART or RS-485 Modbus RTU
  • Measurement depth: up to 40 m
  • Universal usage, direct mounting into containers, silos, vessels, reservoirs, etc.
  • LCD or OLED screen
  • Linear measurement in non-conductive and in differently shaped containers
  • Versions with stainless steel rod or rope electrodes
  • Xi, Xit versions for usage in explosive areas
  • Xd, XdT versions for usage in flammable dusts areas
  • Supply: 18...30/33/36 VDC
  • Protection class: IP67
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.

  • Meter to measurements electric quality parameters in 3 phase systems
  • Programmable display pages
  • 3 programmable alarm outputs and 1 pulse output
  • Digital transmission to the master system through the RS-485 interface
  • USB for configuration by using free eCon software

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Digital input: 4 ch. pulse
  • Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
  • Output: RS-485 MODBUS RTU interface
  • Non-volatile memory for counters storage and settings
  • Galvanically isolated inputs
  • DIN rail mounting
  • Protection class: IP40 (connections IP20)
  • Operating temperature range: -20…+60 °C
  • Power supply: 5…28 VDC
SF6 gas concentration control base station SF6-Network Monitor. The device manages up to 5 units of SF6-Air sensor. Warning and alarm thresholds can be set for each SF6 Air Sensor.The plug-and-play operating concept makes the handling very comfortable. Measuring values can be stored and called on the 5.7" colored touch screen, if necessary. Technical specifications Connection: max. 5 SF6 Air Sensors via bus system Indication: colored 14.5 cm (5.7") touch screen Max. length ..
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications Sensor:  NDIR, 2 Measuring range: 0 ... 1000 ppm ..
  • Self-operating signal lamps (optic signaling of AC/DC voltage presence in 1-phase network via lighting of one non-replaceable LED)
  • LED colors: green, red, yellow
  • Cover - modular, width 17,5 mm
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Applications: in low-voltage systems (130…260 V)
  • Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
  • Recognitions, certifications, directives: RoHS, CE, EAC, UKCA

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C

Hydrostatic level meter HLM–25C is compact measuring device containing ceramic tensometric sensor and evaluation electronics in stainless steel probe. Ceramic sensor is resistant to lightly soiled, or sludge water. From the probe housing comes out 2-wire cable with capillary (for atmospheric pressure compensation). The front side of the sensor is open, therefore the level meter is resistant to capture gross (solid) impurities.

  • For continuous level measurement of clean, lightly soiled, or sludge water in non-pressure reservoirs, boreholes, tanks etc.
  • The measurement range up to 100 m (H2O)
  • The health certificate for contact with potable water available
  • Output: 4…20 mA or 0…10 V

Submersible level sensor CLS–23S is developed as reliable and low-cost solution for limit level sensing of water (or water solutions) with miniature outer dimensions without the needs of any adjustment. The connection is done by means of two wires directly to a circuit with relay or to binary input of control system.

  • For level detection of water in wells, boreholes or tanks
  • Two-wire connection directly to the relay circuit or PLC input (current switch)
  • Maximum immersion depth 100 m
  • Stainless steel protection basket avoids mechanical damages of electrode
  • Supply voltage: 6…30 VDC
  • Protection class: IP68
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265