Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.
The unit is designed for determining dielectric loss tangent and permittivity of transformer oils and other dielectric fluids according to the IEC 60247.
It is a fully automatic device that allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu.
- Applied measuring voltage: 500…2000 V a.c. sinusoidal
- Tan δ measurement range: 0,00001…1
- Tan δ measurement resolution: 1х10-5
- Tan δ measurement accuracy: ± 1 % of measurement + 0,00008
- Measurement range of relative dielectric constant ε: 1,0…15,0
- Accuracy of ε measurement: ± 1 %
- Oil temperature measurement range: 20…110 ᴼС
- Measuring cell volume: 42 cm³
- Power supply: 85...264 V a.c. (48…63 Hz)
ORP electrode sensors (glass, epoxy body and submersible)
The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.
- 30 - 365 days (1TB - 8TB) of onboard storage
- Redundant cloud backup and unlimited cloud-based archiving of footage
- Sensor Resolution: 4 x 5MP (2688 x 1944)
- Protection class / Impact rating: IP66 / IK10
- Operating temperature: -40…+50 °C
- Warranty: 10 Years
- Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
Applications:
Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
- at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line) ≤ 55 V
- at In, C2 (8/20 μs, line-PG) ≤ 500 V
- at C3, 1 kV/µs (line-line) ≤ 48 V
- at C3, 1 kV/µs (line-PG) ≤ 600 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
- For protecting low voltage equipment against lightning and surge damages
- For installation in conformity with the lightning protection zones concept at LPZ 0-1
- Designed according to IEC 61643-11:2011
Specifications:
- Category IEC / EN / VDE: class II+III / type 2+3 / C+D
- Max. continuous operating voltage Uc 275 V AC
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- Voltage protection level Up ≤ 1,5 kV
- Max. backup fuse 125 A
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 19,5 / 18 % vol O2
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Electrochemical gas sensor
- Range: 0...25 % O2
- Resolution: 0,01 % O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 12...36 VDC, 24 VAC or 230 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).
- pH range: 0 ÷ 14.00 pH
- ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
- Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
- Resolution: 0.01 pH, 1 mV, 0.1 °C
- Digital output: RS-485 isolated
- Analog output: 4-20 mA galvanically isolated, "current loop" two wires
- Power supply: 9 / 36 Vdc
- Dimensions: 71x95x58 mm. Rail Din (4 modules)
- Operating temperature: 0…+50 °
- EMC/RFI conformity: EN 61326
pH electrode sensors (glass, epoxy body and submersible)
Instrument PH135 is designed for liquid pH, ORP and temperature measurement.
- pH measuring range: -1.00/15.00 pH, accuracy 0.01 pH
- ORP measuring range: -1200/+1200 mV, accuracy 1 mV
- Temperature measuring ranges: -10.0/+110.0 °C ; -14.0/+230.0 °F
- Alphanumeric LCD display
- Manual and automatic temperature compensation
- Manual or automatic calibration
- Automatic recognition of buffer solutions
- Data logging up to 100 measures
- Alcaline 9 V battery
- Dimensions: 92 x 155 x 33 mm - Weight: approx. 300 g
- Portable analyzer NP40 is designed for power network quality parameter analysis
- Analyses voltage and current harmonics up to 51-st, THD
- Real-time waveform display (4 voltage / 4 current)
- Measurement of TRMS currents up to 3000 A (with standard sensor)
- Half cycle RMS measurement (voltage and current)
- Measurement in 1-phase and 3-phase systems (3- and 4-wire)
- Voltage, current, harmonics, power, energy and other parameter measurement
- Graphical representation of data in a waveform and vector diagram
- Record of events: dips, swells, overvoltages
- Built-in 8 GB memory card
- Ethernet interface for remote monitoring
- USB interface for data transfer
- Color 5,6” TFT display, 320 x 240 px
- Power factor controller for reactive power compensation
- Measures 73 power network parameters (40 visible on screen, all via Modbus RTU)
- Relay outputs: 4 / 6 / 8
- Programmable switch in time, switch off time and discharge time
- Alarm message and relay output
- Optional digital output: Modbus RTU (RS-485)
- Optional real time clock (RTC)
- LCD screen
- Operating temperature: -10...+60 °C
- Protection class (front): IP54
- Panel electromagnetic devices are designed to measure the angle between phase voltage and current in one-phase and three-phase circuits
- Measured value is represented in cosine (cos φ)
- Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
- 54 electrical network quality parameters
- Analysis of voltage and current harmonics (up to the 51-st)
- Color touchscreen: LCD TFT 3.5“, 320 x 240
- 2 configurable alarm outputs
- Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
- Digital output: RS-485 (MODBUS)
- Ethernet / Profinet 2.2
- Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
- Battery backup RTC
- Dimensions: 96 x 96 x 77 mm
- Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
- Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
- Measuring class A or A / S
- Support the IEC 60870-5-104 communication protocol (new - option)
- Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
- Monitoring up to 6 additional energy meters with pulse output
- Recording of measurements before and after events (dips & swells)
- Configurable archives of logged values and events
- SD card support (up to 32 GB)
- Webserver function, FTP server, DHCP client
- Outputs: relays, binary, analog
- Binary inputs
- E-mail alarms
- Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
- Color touchscreen: LCD TFT 5.6“
- Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
- IP65 protection class for front side
- Real time clock (RTC) synchronization with NPT time server
- Time synchronization via external GPS module - STR receiver (new - option)
Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.
The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.
- Two-color LED display
- Backlit units of all measured quantities
- Configurable analog and alarm outputs
- Digital RS-485 interface, MODBUS
- Archiving data in the internal memory file system memory 8 GB
- Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
- services: www server, ftp server, DHCP client
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
Reactive power controller RMB-10S. The device is designed for reactive power compensation battery control. Version with 6 switch outputs is available.
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Digital input: 4 ch. pulse
- Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
- Output: RS-485 MODBUS RTU interface
- Non-volatile memory for counters storage and settings
- Galvanically isolated inputs
- DIN rail mounting
- Protection class: IP40 (connections IP20)
- Operating temperature range: -20…+60 °C
- Power supply: 5…28 VDC
- Modern SCADA system
- Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
- Free license supports only one chosen driver (i.e. Modbus)
- Hardware-independent, communicates with all major industry-standard
- Mobile application (in full version)
- 25 year experience in the marketplace - developed by 7-Technologies which belongs to Schneider Electric
- Relay output
- Smoke sensitivity complies with EN 54-7:2000+ A1:2002
- Digital signal processing
- Very low current consumption
- Excellent long-term stability
- LED indication
- Supply: 10...30 VDC
- Warranty: 3 years
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution < 0,1 / 1,5 ppm SO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 2 / 5 ppm SO2
- Attached or remote sensor
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution 0,1 / 1,5 ppm SO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...50 ppm SO2 / 0...2000 ppm SO2
- Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265
RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.
- IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
- Application: main distribution boards (MB)
- Power networks: TT, TN-S, TN-C
- Protection modes: L-N, N-PE
- Protective elements: MOV, MOV+GDT
- Enclosure: modular (replaceable module)
- Mechanical status indicator: green/red flag
- Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state
- Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Versions according to PN-79/M-53857/05
- Threads for thermometer: metric M12x1.5, M14x1.5
- Lengths: according to customer's specification
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Bore diameters: Ø3.5 mm, Ø7 mm
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Optional designs per DIN 43772 ( form 4 )
- Other materials, threads and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
- Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
- Dimension tolerance according to DIN ISO 2768
- Protection tube coated by layer of CrC to increase abrasion resistance
- Protection tube coated by teflon® PTFE to increase corrosion resistance
- Other materials, threads, flanges and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions