2, 3 or 4 axes ADR10 series indicators for digital systems, linear displacement measurements, movement measurements, positioning detection. These indicators are used with optical and magnetic linear encoder scales ALS or MLS. Error compensation.
Application:
- Lathes
- Milling machines
- Plate metal processing mills
- Grinding machines
- Erosion machines
- Mechanical processing centers
The mini-size multimeter has multiple functions, such as auto range, auto scan (SMART) and true RMS functions, which makes it more convenient and intelligent. Besides normal multimeter function, it also has the function of NCV test and LIVE wire test, which is convenient for field testing. Blacklight and Flashlight capabilities facilitate use in dark work environment.
- CAT III 600V
- TRMS
- AC/DC Voltage measurement: 400 mV…400 V
- AC/DC Current measurement 40 mA … 10 A
- Resistance measurement 400 mΩ … 40 MΩ
- Capacitance measurement 4 nF…4 mF
- Frequency measurement
- Temperature measurement -200…1200 °C
- Auto Scan function (SMART)
- HOLD function, Continuity test and Diode test
- Dimensions: 130 x 62 x 27 mm
Efento Cloud is a platform that allows you to collect, analyse and visualise Efento sensors data, generate reports out of it and notify users, if the values measured by the sensors are out of the safe range. Platform offers webhooks and RESTful API, which can be used to integrate it with any third party software. Users can access Efento Cloud through a web browser and a mobile application.
- Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
- Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
- The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
- Settings can be easily modified with a GSM phone
- Analog inputs: 4 units 4...20 mA (passive or active)
- Digital inputs: 4 units
- Relay outputs: 2 units
- Communication: SMS, GPRS
- Operating temperature: -20...+50 °C
- Supply: 230 VAC / 12 VDC battery
- Protection class: IP65
- Input:
- temperature:
- resistance thermometers: Pt100, Pt500, Pt1000
- thermocouples: J, K, N, E, R, S
- resistance: 400 ohm, 4000 ohm
- current: ± 20 mA
- voltage: 0…10 V, -10…60 mV
- temperature:
- Output: relay (4), analog (1), digital RS-485/MODBUS (1),
- Three-colour display - red, green and orange, programmable in three intervals of the measured value – facilitates the observation of measured value changes.
- digit height: 14 mm
- highlighted measuring unit
- Four alarm outputs with signaling on LED diodes operating in six different modes.
- Universal input (for standard signals and temperature sensors)
- Alarm output
- OLED display
- Configuration via miniUSB connector
- Supply: 24 VDC or 230 VDC / VAC
- IP65 protection class
Digital, programmable indicator N30H for DC voltage, current, with RS-485 interface.
- Device is designed for DC (bi-polar) voltage, current measurement
- LED indicator colors: red, green, yellow (for 3 input value ranges)
- Device is programmed with buttons or via RS-485 port
- 4 alarm inputs in 6 modes
- Measurement value conversion into analog signal 0/4...20 mA arba 0...10 V
- Minimal and maximal value storing for all measurements
- Universal input for measuring temperature, resistance and standard signal
- 4 alarm outputs with signaling on LED diodes
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Analog signal output: 0/4...20 mA or 0...10 V
- Two-line LCD display
- Mathematical functions for converting the measured value
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
- Input: 0...20 mA, 4...20 mA, 0...1 V, 0...10 V
- Display: 4 digits (value range: -1999...4000)
- Measurement unit can be displayed
- Option: 2 x relay output for control and alarm
- Option: sensor supply output
- Option: RS-485 Modbus RTU interface
- Manual calibration
- Stores maximum and minimum measurement values
- Operating temperature: 0...50 °C
- Supply: 230/110 VAC / 12/24 VAC / 9...30 VDC / 7...24 VAC
Digital programmable indicator N20 for temperature, DC voltage and current measurement. Measures J, K, Pt100 temperature sensors’ signals.
Programmable parameters:
- LED indicator color, which changes depending on input signal value: green, yellow and red
- Value limits
- Measurement unit indication
- Cold junction compensation (CJC)
- Compensation for Pt100 sensors
- Averaging time
- Individual characteristic
- 2 OC alarms in 6 modes
Digital programmable indicator N20Z for AC voltage, current and frequency measurement.
Programmable parameters:
- LED indicator color, which changes depending on input signal value: green, yellow and red
- Value limits
- Measurement unit indication
- Decimal point location
- Measured signal
- Averaging time
- Individual characteristic
- 2 OC alarms in 6 modes
Digital programmable indicator N24 for temperature, AC/DC voltage and current measurement. Measures J, K, Pt100 temperature sensors signals.
Programmable parameters:
- Value limits
- Decimal point place
- Measurement unit indication
- Cold junction compensation (CJC)
- Compensation for Pt100 sensors
- Averaging time
- Individual characteristic
- Universal input for standard signals and temperature sensors
- 14 mm height 5-symbol LED display
- 24 VDC output supply for other devices
- IP65 front protection class
- Operating temperature: -10...55 °C
Digital programmable indicator N30B with data logging function and RS-485 interface.
- LED indicator colors: red, green, yellow (for 3 input value ranges)
- Internal memory (up to 350064 records)
- Memory expansion up to 4 GB using a MMC/SC memory card
- RTC (real time clock) – with automatic time change
- Autonomic supply
- Digital, programmable pulse, frequency, motor revolutions, work time meter N30O with RS-485 interface
- Programmable with keys or via computer
- Digital, programmable power network parameter meter N30P with RS-485 interface
- Measures voltage, current, frequency, active, reactive power, cosφ, tgφ, energy consumption
- Programmable with keys or via computer
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
- Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
- 4 alarm outputs with signaling on led diodes, working in 7 different modes
- Analog outputs: 0/4...20 mA or 0...10 V
- Digital output: RS-485 / MODBUS RTU
- Two-line LCD display
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.
- Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
- Nominal input current: 1A or 5A
- True RMS measurement (up to 15th Harmonic)
- On site programmable PT/CT ratios
- User selectable 3ph3wire or 3ph4wire Network (for 3ph)
- Onsite selection of Auto scroll / Fixed Screen (for 3ph)
- 4 Digits 14mm ultra bright LED Display
- Protection: IP54 front / IP20 back
- Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
- Accuracy: ±0.5% of nominal value
- The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
- Long range and high sensitivity internal (or external mounted) antennas
- To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
- The gateway firmware can be upgraded remotely using MQTT
- B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
- Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
- Possible to activate 128 bit AES-key encryption
- Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
- IoT LTE M SIM card needed (acquired separately)
- Self-operating signal lamps (optic signaling of AC/DC voltage presence in 1-phase network via lighting of one non-replaceable LED)
- LED colors: green, red, yellow
- Cover - modular, width 17,5 mm
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Applications: in low-voltage systems (130…260 V)
- Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
- Recognitions, certifications, directives: RoHS, CE, EAC, UKCA
Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.
- Temperature measurement range*: -200…+100 °C
- Relative humidity measurement range*: 0…100 %
- Ambient light measurement range*: 0…10000 lx
- Local storage capacity*: 24200 values for Temperature, Humidity and Light
- Shelf-Life:
- Lithium Battery devices: 12 months (possibility to charge)
- Non-Lithium Battery devices: 6 months (possibility to charge)
- External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
- Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
- Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
- Recording Duration:
- Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Certifications: CE, EN12830, EMC, RoHS, FCC
- Connectivity: LTE 4G cat 1 with 2G Fallback
- Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
- Location: LBS - GSM Localization
- Recommended Storage Temperature: -15…+25 °C
- Inputs: Pt100, thermocouples J, K
- 4-digit 20 mm LED screen
- Automatic or manual compensation
- Programmable input, decimal point, averaging time
- 24 VDC output for external transducers
- Galvanic isolation
- Supply: 230 VAC / 240 VAC / 20...40 VAC / 20...40 VDC
- Protection class: IP65
- Temperature indicator TI-N20, TI-N24 for temperature measurement from -30 to +800 °C
- Various temperature sensor construction types are available
- Temperature indicator TI-N20/5, TI-N24/5 for temperature indication
- Various temperature sensor constructions are available: Pt100, Pt1000; NTC, PTC, termopora K, J
- Three-color numerical display DL21 is designed to indicate various parameters (temperature, humidity, etc.) from external devices via RS-485
- Can be used in offices, industrial and communal buildings
- Indicator color is programmable (green, red and yellow)
- Programming is done via RS-485 port
- Can work in master and slave modes
- Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Display: 3-color LED, 5-digit
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
- Protection class: IP65
- Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Display: 3-color LED, 5-digit
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
- Protection class: IP65
- Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
- Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
- Current measurement range: 0/4...20 mA; ±20 mA (DC)
- Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Auxiliary 24 VDC output to supply transducers
- Display: 3-color LED, 5-digit
- Temperature compensation
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
- Protection class: IP65