This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to DIN 43763 and DIN 43772 (form 4)
  • Lengths: according to customer's specification
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Threads for thermometer: metric M14x1.5, M18x1.5
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Other materials, threads and dimensions
  • Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
  • Ranges: -200...+150°C; -200...+550°C; -200...+600°C
  • Outputs: RTD, 4..20 mA
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
  • Exi RTD sensors for explosive atmospheres with cable
  • Range: -50 .. +400°C
  • Cable insulation: PVC, silicone, teflon, glass fiber
Exi RTD sensors for explosive atmospheres with connection head. Technical specifications Example Model Range Diameter Output XI-TOPGB / XI-APTOPGB -200 .. +150°C Ø9, Ø10, Ø11, Ø12, Ø15 mm RTD, 4..20 mA XI-TOPG / XI-APTOPG -200 .. +550°C Ø11, Ø12, Ø14, Ø15 mm RTD, 4..20 mA XI-TOPT / XI-APTOPT -200 ...
Exi RTD sensors for explosive atmospheres with mineral insulation. Technical specifications Example Model Range Diameter XI-TOPI / XI-APTOPI -200 .. +600°C Ø3, Ø4.5, Ø6, Ø8 mm XI-TRP-BTW -50 .. +600°C Ø1.5, Ø2, Ø3 mm XI-TRP-WL -50 .. +600°C Ø1.5, Ø2, Ø3, Ø4.5, Ø6 mm XI-TRP-TKbW ..
  • Exi thermocouple sensors for explosive atmospheres
  • Range: -40...+1200°C
  • Exi thermocouple sensors for explosive atmospheres with cable
  • Range: -40...+400°C
  • Exi thermocouple sensors for explosive atmospheres with connection head
  • Outputs: TC, 4..20 mA

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..
  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446
Multipoint thermocouple temperature sensor TTP-328 is designed for temperature measurement. Suitable for energetics, oil and chemistry industries Every sensor is made out of mineral-insulted cable Process connection is threaded or flanged Compact design Maximum immersion depth is 30 m ATEX design Various variants are possible, depending on client’s request Every sensor can be mounted by up to 24 temperature transmitters. In order to bring the start-up cost down, sensor can be configured by our company. More on TTP-328 multipoint thermocou..
  • 2 analog outputs (operating simultaneously):
    1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
    2. Voltage 0...10 V.
  • Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
  • 7-segment LED display with adjustable brightness
  • Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
  • Password protection
  • High accuracy and immunity to interference
  • Supply: 230 VAC or 24 VAC/VDC
  • Panel housing 96 x 48 x 79 mm
  • Protection: IP65 (front) / IP20 (back)
RTD sensors TOPE with cable. Technical specifications Example Model Range Protective tube Cable insulation TOPE150 -50 .. +400°C Ø5, Ø6, Ø8, Ø9, Ø10 mm PVC, silicone, teflon, glass fiber TOPE3 -50 .. +400°C Ø5, Ø6, Ø8 mm TOPE4   TOPE310 -50 .. +400°C Ø5, Ø6, Ø8 mm ..
RTD sensors TOP with connection head. Technical specifications Example Model Range Accuracy Tube diameter TOPGB -50…+150°C A class (standard)orB  class according to EN 60751 various variants available TOPGN -200…+600°C TOPG -200…+600°C TOPI -200…+600°C ..
RTD sensors TRP with mineral insulation. Technical specifications Example Model Range Diameter TRP-NA -50 .. +600°C Ø1.5 .. Ø6.0 TRP-BTW -50 .. +600°C Ø1.5 .. Ø3.0 TRP-WL -50 .. +600°C Ø1.5 .. Ø6.0 TRP-TKbW -50 .. +600°C Ø1.5 .. Ø6.0 ..

Temperature regulator SCD210 is designed for temperature control in various devices and rooms. Made in three variants with different inputs. SCD210 has a step set point (SP) value change by signal option in binary input.

RTD sensors with TOPGDM, TOPGDS connectors. With threaded process connector, designed to measure temperature in pipes, tanks and canals. Measuring range is -50...+400 ºC. Can be fit with a LED display.

The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.

  • Temperature measuring range: 0… +1800 °C
  • Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
  • Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
  • Gastight process connection: (to 0.1 MPa / 1 bar)
  • Optionally the head can be installed with a local temperature display (DANWdie-LED)
  • ATEX and EAC Ex versions
  • For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444

 

 

Thermocouple sensors TTE with cable. Technical specifications Example Model Range Protective tube Cable insulation TTE310 -40 .. +400°C Ø5, Ø6, Ø8 mm PVC, silicone, teflon, glass fiber TTE311 TTE312 TTE409 -40 .. +400°C Ø5, Ø6, Ø8 mm TTE410 TTE411 -4..
Thermocouple sensors TT with connection head. Technical specifications Example Model Range Accuracy Tube* diameter TT_G -40…+800°C 1 class (standard) or 2 according to EN 60584 Various variants available TT_GB -40…+150°C TT_GN -40…+800°C TT_P -40…+800°C ..
Thermocouple sensors TTP with mineral insulation. Technical specifications Example Model Range Diameter TTP-NA -40 .. +1250°C Ø1.0 .. Ø8.0 TTP-BTW -40 .. +1250°C Ø0.25 .. Ø3.0 TTP-WL -40 .. +1250°C Ø1.0 .. Ø6.0  TTP-TKbW -40 .. +1250°C Ø0.25 .. Ø8.0 ..
  • Measurement range: -40…+180 °C
  • Type: J / K / N / T / E
  • Self-adhesive tape
  • Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
  • Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
  • Optional: connector
Thermocouples TTP-320, TTP-321, TTP-322 are suitable for temperature measurement of industrial furnace pipes. Suitable for energetics industry Suitable for oil and chemistry industries Made out of mineral-insulated cable Good vibration resistance Spiral windings for vibration protection Two possible variants, chosen according to client’s request ATEX design Thermocouple TTP-320...TTP-322 description [EN]More on TTP-320...TTP-322 thermocouples on Termoaparatura Wroclaw website [EN] ..
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to PN-79/M-53857/05
  • Threads for thermometer: metric M12x1.5, M14x1.5
  • Lengths: according to customer's specification
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Optional designs per DIN 43772 ( form 4 )
  • Other materials, threads and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
  • Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
  • Dimension tolerance according to DIN ISO 2768
  • Protection tube coated by layer of CrC to increase abrasion resistance
  • Protection tube coated by teflon® PTFE to increase corrosion resistance
  • Other materials, threads, flanges and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming

General purpose regulator AR630 is designed for usage in humid or dusty environment (IP65). RS-232, RS-485 or analog ports are optional. Two programmable inputs (for temperature sensors and DC). Settings are protected by password. Set point blocking. Manual output control. Modification AR632 has two indicators (for set point (SP) and process value (PV)).

General purpose regulator with one programmable input and 2 or 3 outputs. Variant with RS-485 is used for work in measuring systems. Programmable binary input for remote work mode modification. PID autotuning. Free software for configuration. Manual control feature.

  • Sensor AR434 compatible with Wireless data logger AR407
  • Input:
    • RTD: Pt100 / Ni100
    • TC: J / K / S / B / R / T / E / N
    • Analog: 0…20mA / 4…20mA / 0÷10V / 0…60mV
    • Resistance: 0…700Ω
  • Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated requires supplying sensor via the mini-USB port)
  • Built-in measurement of ambient temperature (20…70 °C)
  • LCD display showing the measured values, messages and errors
  • Protection: IP20
  • Power supply: battery (3.6 V, AA type)
  • Battery lifetime: up to 2 years, at room temperature, with measurement period > 40 min and uninterrupted radio transmission
  • Parameter configuration via USB serial interface
  • Variation of device without LCD screen (AR433)
  • Data presentation and recording from up to 16 measuring channels
    • Wireless sensors of AR43x series
    • Any device with RS485 interface using MODBUS-RTU protocol
    • Any device with Ethernet interface using MODBUS-TCP protocol
    • One wired temperature sensor (AR182 or AR183)
  • Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated)
  • Color LCD TFT graphic display with a touch screen
  • 4 alarm outputs with acoustic and visual signaling of the operational status, possibility to send alarms by e-mail
  • Internal memory: 4GB enough for 300 days of continuous recording of 16 channels every 1 second
  • Time control / timer for outputs, available options: continuous operation, periodic daily (hourly), or limited by date and time
  • Interfaces: USB, RS485, Ethernet
  • Web server contains information about measurement channels, time, status of the alarms, recording, etc.
  • Software for displaying recorded results as graphics or text (ARsoft-LOG) and for configuring the parameters (ARsoft-CFG)
  • Protection: IP65 or IP30 from the front / IP20 from connectors side
  • Power supply: 230VAC / 24VAC / 24VDC
  • Operating temperature: 0…50°C
  • Sensor AR437 compatible with Wireless data logger AR407
  • Temperature measurement range: -30…+80 °C
  • Humidity measurement range: 0…100 % RH
  • Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated requires supplying sensor via the mini-USB port)
  • Protection: IP65
  • Power supply: battery (3.6 V, AA type)
  • Battery lifetime: up to 4 years, at room temperature, with measurement period > 30 min and uninterrupted radio transmission
  • Parameter configuration via USB serial interface
  • Device variation with external sensor (AR437/2)
  • Sensor AR436 compatible with Wireless data logger AR407
  • Temperature measurement range: -20…+70 °C / with external probe: -30…+80 °C
  • Humidity measurement range: 0…100 % RH
  • Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated requires supplying sensor via the mini-USB port)
  • LCD display showing the measured values, messages and errors
  • Protection: IP20
  • Power supply: battery (3.6 V, AA type)
  • Battery lifetime: up to 2 years, at room temperature, with measurement period > 40 min and uninterrupted radio transmission
  • Parameter configuration via USB serial interface
  • Variation of device without LCD screen (AR435)
Loading...