The ATEX IBC Heater series is a safe, efficient, and customizable heating solution for IBC containers located in hazardous areas. IBC heaters are used for protection against frost, temperature maintenance and process heating in a wide range of industries.
Technical Specifications:
- Heats IBCs from -40°C to +200°C for steel, +80°C for plastic, ideal for industries like oil, gas, and pharmaceuticals.
- Fits standard 1000-liter IBCs, optional insulating lid, for indoor/outdoor use, IP65/I dust and water jet protection.
- Ready to use, fully configured with EC-type certificate, no additional acceptance needed.
- Variable voltage, power, and size options, for temperature classes T6 to T3.
- Compatible with optional ATEX controller for temperature management.
- Nominal voltage: 230 VAC*
- Nominal power: 2400 W (container heater) (insulation lid) without heating
- Max. operating temperature: +180°C / +200°C (steel IBC-Container), +80°C (plastic IBC-Container)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 30kg (container heater), 5kg (insulation lid)
The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.
Technical Specifications
- Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
- Zones: Suitable for Zones 1, 2, 21, and 22
- T-Class: T6, T5, T4, T3, T2, T1
- IP Rating: IP65 for dust and water resistance
- Operating Temperature: 65°C (energized) / 85°C (de-energized)
- Ambient Temperature: -20°C to +55°C
- Power Output: Self-limiting heating cable, adjustable to drum size
- Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
- Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
- Available Sizes: For 200/220L drums
- Applications: Frost protection, temperature maintenance, chemical processing
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
The ATEX Gas Bottle Heater series is a safe, efficient, and customizable heating solution for gas bottles located in hazardous areas.
- Nominal voltage: 230 VAC*
- Nominal power: 380W, 850W, 850W (10L, 50L, 79L) or application-specific
- Max. operating temperature: +50/60°C (jacket max. 200°C)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 6kg, 9.5kg, 10kg (10L, 50L, 79L)
- Flow monitoring with SIL1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
- Can be used in ATEX zones 1 and 2 in conjunction with 2 Zener barriers supplied
- Large measuring range from 0.1 to 30 m/s with media temperatures from 0°C to 60°C
- With switching output suitable for control cabinet installation
- Developed for demanding industrial applications, IP40
- Example areas of application: Flow monitoring in paint shops, paper factories and research facilities
- Air flow monitor for monitoring air flow in ATEX zones 1 and 2 (optionally additionally with SIL1 or SIL2 certification)
- With switching output (1 NO/ 1 NC) for control cabinet installation
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Large measuring range (0.1...30 m / s), simple and fast commissioning
- Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC, industrial furnaces, granulate dryers
- Suitable for ATEX Zones 2 and 22
- Electrochemical gas sensor
- Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life pellistor (catalytic bead) sensor
- Range: 0...15% vol. (0…100% LEL)
- Resolution: 0.1% vol. or 1% LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -10...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life photoacoustic or optical NDIR sensor
- Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
- Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...10 / 0...200 / 0...1500 ppm
- Resolution: 0,1 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
- Stable long-life metal-oxide sensor
- Range: 0…1000 / 0…2500 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...100 ppm, 0...2000 ppm H2S
- Resolution: 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL CH4
- Resolution: 0,1 / 1 % LEL CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0…250 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life optical NDIR sensor
- Range: 0…1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...25 % vol O2
- Resolution: 0,01 % vol O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply
- Configurable by the software DEV9K
- Galvanic isolation on all the ways (1500 VAC)
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
- Configurable by the software DEV9K
- Capable to connect the sensors to the analog inputs
- Galvanic isolation on all the ways (1500 VAC)
- Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
- Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
- 2000 VAC galvanic isolation
- High accuracy
- EMC compliance - CE symbol
- Mounting on DIN rail - EN-50022 complience
- Supply voltage: 10...30 VDC
- Ambient temperature: -10...+60°C
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
- Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
- Configurable using webserver
- RS-485 (Modbus RTU Master)
- Distance up to 1200 m, up to 32 modules
- LED indication
- Galvanic isolation in all ways (1500 VAC)
- EMC compliance
- Mounting on DIN rail - EN-50022 compliance
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
- Input (configurable): TC, RTD, mV, resistance and potentiometer
- Output: Modbus RTU / ASCII Slave device over RS-485
- 1500 Vac 3-ways Galvanic Isolation
- High accuracy
- Remotely configurable over RS-485
- EMC compliance (CE mark)
- Mounting in B-type head
- Easy implementation in existing PLCs and SCADA systems
- Operating temperature: -40...+85°C
- Supply voltage: 18...30 VDC
The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.
- Temperature measuring range: 0… +1800 °C
- Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
- Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
- Gastight process connection: (to 0.1 MPa / 1 bar)
- Optionally the head can be installed with a local temperature display (DANWdie-LED)
- ATEX and EAC Ex versions
- For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444
The sensor SVT300-V require to be used with Broadsens's wireless gateway and advanced vibration analysis software BroadVibra.
- Alarm sent out in 0,5 second when accident detected
- Acceleration range: 2g to 16g auto adjustment
- Acceleration sampling rate: Low speed & 6.4kHz sampling rate dynamic adjustment based on vibration level
- Acceleration resolution: 16 bit
- -3dB bandwidth (Hz): x,y,z axis: 0.1Hz to 3.2kHz
- Temperature measurement range: -40…+125 °C
- Wireless data transmission (BLE): 2.4GHz; up to 300 m in open space. FCC / IC approved
- Battery life: 3…4 (12-hour running machine a day); 14250 battery, 1200 mAh
- Mounting: M6 screw hole or two screw-hole case
- Working temperature: -55…+85 °C; IP68 (IP69K optional)
- Explosive atmosphere: Intrinsic safe. ATEX & IECEx: Ex ia IIC T4 Ga; Ex ia IIIC T135 Da