- Sturdy
- Hanging hook
- 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
- The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
- Max discharge head: 5,4 m
- Max pressure: 5,7 m
- Tank volume: 2 L
- Automatic turn on specific level in tank
- Overdraft level safety switch
- Stainless steel motor shaft
- Protection class: IP44
- Max condensate temperature: 55 °C
- Max condensate acidity: pH > 2,5 (Gas condensing boilers)
- Quick installation with mobile app
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
- To measure carbon dioxide in air and neutral gases range 0…5000 ppm
- Configuration with switches or software: measuring ranges, outputs settings
- Optional with display or without display
- Ambient and duct models. Duct model available only without display
- The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
- Max discharge head: 0,9 m (flow rate = 24 l/h)
- The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
- The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
- Protection class: IPX4
- Operating conditions: 100 % - continuous duty
- Measurement range: -40...+150 °C, -1...60 bar
- Temperature measurement accuracy: ± 1,3 °C
- Pressure measurement accuracy: ±0,5 % of full scale
- Operating temperature: -20...+50 °C
- Overload: 65 bar
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
- Applications of flue gas analyzer Si-Ca 130: boilers, burners, water heaters and furnaces
- Detectable gases: O2, CO, CO(H2), CO2, NO, Low NO, NOx, Low NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
- To measure air and neutral gases pressure in range -10 000...10 000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -10 000...10 000 Pa
- Accuracy: ± 1.5 % of reading ± 3 mmH2O
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 69 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- To measure air and neutral gases pressure in range -100...100 Pa
- Solenoid valve for auto-calibration: frequency 1…60 min
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -100...100 Pa
- Accuracy: ± 1 % of reading ± 2 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output: 0-10 V and 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply: 24 V AC / V DC
- To measure air and neutral gases pressure in range -1000...1000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -1000...1000 Pa
- Accuracy: ± 1.5 % of reading ± 3 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -2000...2000 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -2000...2000 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 4100 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -500...500 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -500...500 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 1400 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
- Detectable gases: O2, CO, CO2, NO, NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
- Color display screen with buttons
- Communication: Bluetooth (mobile App), remote printer
- Measurement storage: smartphone
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Temperature measurement range:
a) Ambient model: -20...+80 °C
b) Remote model with polycarbonate probe: -20...+80 °C
c) Remote model with stainless steel probe: -40...180 °C - Relative humidity measurement range: 0...100 %
- Calculates dew point, absolute humidity, enthalpy and combination ratio
- 4-wire analog output: 0...5/10 V or 0/4...20 mA
- 2 relay outputs
- Versions with or without display
- Protection class: IP65 (ABS V0 housing)
HST comes in three models, HST-M – standard model (IP20), HST-D – remote sensor (IP65) and HST-A – channel model (IP65).
- Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
- Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
- Up to six gas sensors
- CO measurement up to 50 000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
- Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
- Coefficient: 1,0015 ± 0,01
- Max static pressure: 2 bar
- Temperature of use: 0…600 °C (up to 1000 °C in option)
- Measurement range: -40...+150 °C, -1...60 bar
- Temperature measurement accuracy: ± 1,3 °C
- Pressure measurement accuracy: ±0,5 % of full scale
- Operating temperature: -20...+50 °C
- Overload: 65 bar
- Two valve system
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
Micro-manometer MG (differential, liquid) MG20, MG40, MG50, MG60, MG80, MG100.
Micro-manometer TJ (differential, liquid) TJ100, TJ150, TJ300, TJ600, TJ1000.
Micro-manometer TX (differential, liquid) TX25, TX50, TX75.
♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option
- Measured parameters (with respective sensors):
a) Temperature (Pt100 or thermocouple)
b) Humidity
c) Air quality
d) Air velocity
e) Airflow
f) Tachometry - Two inputs for Pt100 temperature sensors (range -200...600 °C)
- Up to 6 measurements simultaneously
- Power supply: Lithium-Ion battery (up to 57 hours)
- Calibration certificate, additional battery, transport case included
- Operating temperature: 0...50 °C
- Protection class: IP54
Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.
- Measurement range: -40...+150 °C
- Temperature measurement accuracy: ± 1,3 °C
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- Cable of 2 m length
- 124 refrigerant gases
- Pressure measurement range: -1...60 bar
- Pressure measurement accuracy: ± 0,5 % of full scale
- Overload: 65 bar
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- 124 refrigerant gases
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
- Air velocity, airflow and temperature measurement
- Air flow measurement with a cone
- Automatic average
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Detection of flow direction
- Selection of units
- Supplied with calibration certificate
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Automatic average
- Selection of units
- Detection of flow direction (LV 110/LV 117)
- Supplied with calibration certificate
- Air flow measurement with a cone (LV 110/LV 117)
- Pressure measurement range: 5...25000 μm
- Operating temperature: -10...+50 °C
- Overload: 610 bar
- Two valve system
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases