This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Lumel

Show:
Sort By:
  • Measurement channels: up to 24
  • Analog inputs: 12
  • Relay outputs: 6 or 32
  • Analog outputs: 4 or 8
  • Digital outputs: RS-232, RS-485, USB
  • Screen: touchscreen LCD TFT 5.7”
  • Memory: CompactFlash memory card, up to 4 GB
  • Visualization of measurements in digital form, analog indicators, diagrams, bargraphs
  • Ethernet, Webserver, FTP server, Modbus Slave TCP/IP
  • Diversified users’ access rights
  • PC software
  • Protection class: IP65 (front)
  • Operating temperature: 0...55 °C
  • Supply: 230 VAC

  • Used for measuring range extension and conform to EN 60051 standard
  • Can be used in various measuring systems
  • Shunts are selected by nominal current (1 – 15000 A)

The P17 transducer, supplied from a current loop, converts the signal from temperature sensors or a standard voltage signal into a 4...20 mA current.


  • Dedicated to following devices: N14, N27P, N30P, N43, N100, ND10, ND20, P41, P43
  • Monitors, archives, visualizes measured data, generates reports
  • Communication protocols: Modbus RTU, Modbus TCP
  • Reading interval: 1...60 s
  • Archiving interval: 1 s...1 h
  • License types: for up to 5 / 10 / 30 / 50 devices
  • Optional communication with other Modbus RTU/TCP devices
  • Multiple user access with varying levels of authorization
  • Remote access to PowerVis software through a web browser
  • Languages: English, German, French, Spanish and Polish

  • Available versions with 2 to 8 primary windings
  • Nickel plated secondary terminals
  • Multiple mounting methods, including wall mounting and on DIN rail
  • Applicable standard: IEC 61869-1/2
  • Rated primary current: (2...8) x 5 A
  • Rated secondary current: 5 A
  • Rated burden: 5 / 10 / 15 / 20 / 25 A
  • Max system voltage: 720 V
  • Operating temperature: -25...+40 °C
  • Accuracy class: 0,5 / 1

  • Destined to synchronize generator, wind, water turbine and similar devices connecting to the network
  • Eliminate voltage difference, frequency, and phase shift angle
  • Ethernet interface 10/100 base-t, RS-485 interface with Modbus RTU protocol
  • Web server, Modbus TCP / IP, DHCP server
  • Protection class from frontal side: IP65, terminal side: IP20
  • Electrical safety CAT III measurement category
  • Voltage range (resolution): 20...180 V (0,1 V), 60...480 V (0,1 V), ...1920 kV (0,01 kV)
  • Voltage difference (resolution): -20...0…20 % (0,1 %)
  • Frequency range (resolution): 45...65 Hz (0,001 Hz)
  • Frequency difference (resolution): -10...0...10 % (0,01 %)
  • Phase shift (resolution): 0...360 o (0,1 o)

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)

  • Two set points
  • Input: TC (J, K, T, R, S) / RTD (Pt100)
  • Control output: relay or SSR
  • Auxiliary output: relay
  • PID / ON-OFF control
  • Auto-Tuning / Self-Tuning
  • Alarm modes: deviation, absolute
  • Heating / cooling control
  • 4+4 digits high contrast LED display
  • Supply: 85…270V AC / DC
  • Ambient temperature: 0…50 °C

  • Inputs: Pt100, thermocouples J, K
  • 4-digit 20 mm LED screen
  • Automatic or manual compensation
  • Programmable input, decimal point, averaging time
  • 24 VDC output for external transducers
  • Galvanic isolation
  • Supply: 230 VAC / 240 VAC / 20...40 VAC / 20...40 VDC
  • Protection class: IP65

  • Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
  • Universal input for thermocouples and resistance thermometers
  • Relay output for disconnecting the temperature control system
  • Supply: 230 VAC
  • Operating temperature: 0...50 °C

  • Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
  • PID or ON/OFF control
  • Automatic selection of PID parameters
  • One relay output and one alarm relay
  • Manual control mode
  • One binary input
  • Operating temperature: 0...50 °C
  • Supply: 230 VAC
  • Protection class: front IP65, back IP20

  • Three-color numerical display DL21 is designed to indicate various parameters (temperature, humidity, etc.) from external devices via RS-485
  • Can be used in offices, industrial and communal buildings
  • Indicator color is programmable (green, red and yellow)
  • Programming is done via RS-485 port
  • Can work in master and slave modes

  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder

  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input

  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder

  • PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
  • This enables to increase device number in the system and extend its range

  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable

  • Up to 10 / 15 m level measurement with automatic temperature compensation
  • Calculation of filling in the tank or flow in open channels
  • Galvanically isolated 0/4...20 mA analog output
  • Digital RS-485 Modbus RTU interface
  • 2 alarm outputs
  • Internal data and setup memory
  • Two 32-points individual characteristics (for recalculation)
  • LCD screen
  • Housing protection grade: IP66
  • Sensor protection grade: IP66 / IP 68
  • Supply: 12...25...40 VDC
  • Operating temperature: -20...23...55 °C

  • Up to 10 / 15 m level measurement
  • Analog output: 4…20 mA
  • Digital output: RS-485 Modbus RTU
  • Resolution: 3 mm
  • Supply: 24 VDC / 300 mA
  • Operating temperature: -20...60 °C
  • Cable length: 1 m

  • Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
  • Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
  • Universal input for RTDs, thermocouples and analog signals
  • Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
  • The controller has three alarms, which can be assigned to each output
  • The output signals are galvanic isolated from the input signals and power supply
  • Selection of PID parameters for any unit, or auto-tuning
  • Protection class from frontal side: IP30, from terminal side: IP20

The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).

Main features:

  • Sampling rate (5 times / second)
  • 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
  • 2 input: 0 / 4…20 mA and 0…10 V
  • Binary input for changing the function of the controller and SP switching
  • Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
  • Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
  • Programmable digital filter
  • Hardware and software security before changing settings
  • Alarm for breaking the control loop
  • Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
  • Protection class: IP65

The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.

  • Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
  • Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
  • Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
  • Profile Controller: Up to 128 steps
  • Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
  • Communication: RS485 MODBUS RTU
  • Power Supply: 90...270 VAC / DC (50/60Hz)
  • Display: 4+4 digit, 7 segments
  • Ambient temperature / humidity: 0…+50 °C / < 85%RH
  • Dimensions: 52 x 52 x 76 mm

  • In PD24 converter are used 2 interfaces (USB, RS232) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-232 interface - destined for the communication with devices from the object side
  • PD24 is programmer of LUMEL products to configure settings using eCon software
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Device supplied from USB port and from the RS-232 (TTL) side
  • Set includes 1,5 m data transmission cable with RJ12 plugs to configure LUMEL products
  • External dimension: 62 x 25 x 20 mm

  • In PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-485 interface - destined for the communication with devices from the object side
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Bi-directional data transmission (half duplex)
  • Device supplied from USB port
  • External dimension: 76 x 25 x 20mm
  • Converter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols

  • The program is designed to represent and log measured values
  • Representation tools: bar graphs, graphs, numbers
  • Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
  • Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
  • Data logging: tables and/or graphs in PC memory

  • Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
  • Protection class: IP65

  • Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65

  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65

The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.

Applications: Motor protection, Server rooms, Control system

Features:

  • Compact size 17.5 mm
  • True RMS measurement
  • Under voltage protection
  • Over voltage protection
  • Phase unbalance protection
  • Phase failure protection
  • Phase incorrect sequence protection
  • Neutral failure protection
  • Adjustable Nominal voltage, Trip point, Trip time delay
  • Onsite selection of VLL / VLN value-based tripping
  • Self-powered
  • 1CO, 1CO+1CO relay configuration
  • LED indication for faults
  • Disabling of Over & Under Voltage fault on site is possible

  • Voltmeters for AC voltage measurement EP27, EP29 with a change-over switch
  • Panel electromagnetic devices, designed for effective voltage measurement
  • Change-over switch, when activated, enable the measurement of linear and phase voltage (6 measurement points)
  • Tropical version is available (TIII)
  • Voltmeters for usage with voltage transformers (X/100 V and X/110 V) are also available

Loading...