The constant speed actuators of the XI type for modulating duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or a lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The modulating duty XI actuators may differ in design of their control blocks as the control panel m..
Zpua actuators with ATEX certification. Spindle Nominal rotation speed from 20 to 240 NmLinear Nominal force value from 10 to 60 kNLever Torque from 250 to 32000 N..
The constant speed type XS actuators for open-close duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The XS and X-MATIK actuators for open-close duty differ one from another with a control block as that block i..
The constant speed type XS actuators for open-close duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The XS and X-MATIK actuators for open-close duty differ one from another with a control block as that block i..
- Portable, small dimension temperature meter with a probe
- The probe can be 1,5 m, 3 m or of specified length
- Temperature measurement accuracy: ±1 °C
- Temperature measurement range: -50...+150 °C
- LCD screen
- 2 year warranty
- Supply: 1x6LF-22 (9 V)
- Module is designed to protect battery if it discharges below 10,5 V mark, disconnecting it from load
- Battery is automatically reconnected to load if its voltage rises
- Suitable for work with heaters, lighting, travel refrigerators, etc.
- Operating voltage: 12 V ZBxx, 24 V ZBxx-24V, 48 V ZB-48V
- Maximal current: 40 A ZB40, 80 A ZB80, 140 A ZB140
- Operating temperature: -20...50 °C
- Dimensions: 65 x 89 x 70 mm
- Measurement range: 32…43 °C
- Measurement accuracy: ± 0,3 °C
- Measurement distance: 0…5 cm
- Measurement duration: 1 s
- Measurement location: forehead
- Automatic shut-down: 30 s
- Measurements: 149 x 38 x 42 mm
- Operating temperature: 10…40 °C
- Operating humidity: ≤ 85 %
- Certificates: ISO13485, CE, CFDA
- Supply: 2 x AAA batteries
Microprocessor controller INDU-30 with RS-485 interface for temperature and humidity control in food and other industries. The device is designed for temperature and humidity control in food and other industries (drying, climate chambers, etc.). Humidity measurement is done via psychorometer method. Two programmable inputs are used for temperature sensor connection and one for standard signal 0/4...20 mA. Version for work with thermocouples is also available. The device can log measured values in set time intervals. Data is transferred via RS-485 interface. Control starts in set t..
Microprocessor controller INDU-50 with RS-485 interface for temperature control in thermal processing devices in food industry. The device is intended to be us in boiling pots, vaporizers, grills, climate chambers and so on. Measured values can be logged into the internal memory. Data is transferred via RS-485 interface. Real time clock. Control starts in set time or after set delay. Technical specifications
Input:
2 analogue inputs PT-100 (PT-500, PT1000)
channel 1: temperature – ‘dry’ thermometer
channel 3: temperature – ‘we..
- Data logger for level measurement up to 100 m
- Measuring interval: from 0,5 s to 24 hours
- Data capacity: up to 500 000 values
- Interface: RS-485
- Ambient temperature: -5...50 °C
- Protection class: IP67
- Sensor material: stainless steel 1.4435 (316L)
- Supply: 3,6 V lithium battery
- Included: 110 m PE cable, RS-485 converter, software
1,185.80 € 770.77 €
Ex Tax: 637.00 €
Ex Tax: 637.00 €
Temperature and humidity mini data loggers SL5x. Operating temperature from -40°C to +140°C, designed for temperature measurements or temperature and humidity measurements logging. Due to small size (Ø17x6 mm) these data loggers can easily be fit in small objects and packages. ♦ Compact size♦ Sturdy and reliable construction♦ Wide range of accessories♦ Free software♦ Data export function♦ Cold supply chain assurance while transporting and storing pharmaceuticals and biotechnological products, chemicals and food products which require special transport and stora..
- Triton Vape Detector detects of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
- Monitoring of Humidity, Particulate Matter Index and VOC Index
- Rejects most aerosols with a similar profile to vape/smoking
- Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
- Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
- Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
- Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
- Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
- Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V
Portable temperature calibrator for dry air Pyros 650. These innovative calibrators have been designed for on-site applications and for the severe conditions of the naval and marine sectors. Their ease of use, compact and practical design make them unbeatable in industrial processes where the verification of the temperature measurement systems is a key issue for the control of the process and the quality of the final product. Special attention was paid to reduce the weight, to the small size and sound design obtained by using an aluminum body and aluminum and stainless steel for m..
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
Fluid level electrode 11 SN1 for fluid level measurement.
Ambient temperature
≤ 60°C
Electrode material
Stainless steel (AISI 303)
Casing material
Plastic (PPOX)
Connection
PG7 collar (for cable from 2,5 to 6 mm2 ) More on electrode 11 SN1 on Lovato website [EN]11 SN1 datasheet [EN]
..
Fluid level electrode 31 CGL125 3 for fluid level measurement.
Ambient temperature
≤ 180°C
Electrode length
300 mm
Electrode material
Stainless steel (AISI 303)
Operating pressure
≤ 10bar
Insulator
Teflon
Process connection
G 3/8'' More on electrode 31 CGL125 3 on Lovato website [EN]31 CGL125 3 datasheet [EN]
..
Fluid level electrode 31 PS31 for fluid level measurement. Technical specifications
Ambient temperature
≤ 70 °C
Electrode length
300 mm
Electrode material
Stainless steel (AISI 303)
Operating pressure
≤ 2 bar
Insulator
Teflon
Process connection
G 1/2'' More on electrode 31 PS31 on Lovato website [EN]31 PS31 datasheet [EN]
..
Fluid level electrode 31 SCM 04 for fluid level measurement. Electrode extension is available, M4 thread. Technical specifications
Ambient temperature
≤ 100 °C
Operating pressure
≤ 10 bar
Electrode length
40 mm
Electrode material
Stainless steel (AISI 303)
Casing material
Plastic (PPOX)
Insulator
Ceramics
Connection
PG7 co..
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- External probes can be connected
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- Calibrated for more than 400 grain species
- 2” LCD screen
- USB connection for software updates and data transfer
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
- Portable, small dimension grain moisture meter
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±1 % (in range up to 10 %)
- Calibrated for more than a hundred grain types (the list can be extended)
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 2xAA (1,5 V, LR6)
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Calibrated for more than 400 grain types
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 1x6LF-22 (9 V)
Hay and straw moisture and temperature meter DRAMINSKI HMM works by measuring electrical conductivity variation. HMM measures hay/straw moisture and indicates it on the LCD screen. Measured value is shown in percentage. Device can measure temperature. Has internal memory which stores last 50 measurements. Shows maximal, minimal and average values.
Technical parameters
Measuring range:
Moisture
Temperature
10...80%
1…100°C
..
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±1 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- LCD screen
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
A simple handheld, accurate vape particulate, vape smoke detector FD-VAPE-HAND that indicates air quality for home, work, vehicles, or other occupational spaces. Excellent to detect vape, cigarette smoke, and e-cig smoke.
- Sensor: Laser scattering PM1.0, PM2.5, PM10 sensor
- Detection Range: 0-1000 µg/m3
- Response Time: <10 seconds
- Temperature measurement range: 0…50 °C (can be selected between Fahrenheit and Celsius)
- Humidity measurement range: 10…95 %RH
- Sound alarm when vape detected
- Auto off: after 5 minutes
- Power: 1000 mAh Li-Ion Battery, up to 8 hours of operation, (recharge USB 5V/1A)
- Dimensions: 5,1 x 1,8 x 8,6 cm
- Weight: 142 gr
- Communicates with devices supporting HART and LHP interfaces
- Supports universal, common commands
- HART connector: BNC
- Supply: 9 V accumulator (charged via USB)
- Operating temperature: -20...+50 °C
- Operating humidity: 0...80 % RH
- Protection class: IP40
Horizontal float level sensor LH, designed for fluid tank monitoring, usage in automation, testing, measuring and control devices.
Switching power
≤ 10 W
Switching voltage
≤ 200 V AC/DC
Switching current
≤ 0,5 A AC/DC
Ambient temperature
-20...90 ºC
Casing material
PP (polypropylene) for water and weak acid devices More information PDF [LT]
..
Horizontal stainless steel float level sensor LB-1. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Horizontal stainless steel float level sensor LB-2. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection: 1/2 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Non-reversible temperature labels, 10 temperature ranges.
A
°F°C
10440
10842
11144
11546
12049
12954
14060
14462
14965
16071
B
°F°C
17177
18082
19088
19993
21099
..
The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.
- Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
- Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
- Tamper protection: device vandalism, masking and covering
- Real-time monitoring of student loitering via live video streaming
- No license subscription required for use
- The sensor independently performs all measurements and detections and sends alarms itself
- *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
- Event logging of alarms in the device
- Communication: LAN, WiFi
- Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
- Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
Overload protector 05-04. Designed to protect pressure measuring devices from too fast or too big step change of pressure. This device blocks bigger than expected pressure until system gets back into normal state. Technical specificationsMaximum working pressure: 400 bar;Process connection: 1/2 BSP MxF, 1/2 NPT MxF, 1/4 BSP MxF, 3/8 BSP MxF, 3/8 NPT MxF;Material of construction: AISI 316 SS;Operating temperature: -40°C .. 120°C; 05-04 datasheet [EN]
..
The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.
- Protective transparent flexible rubber casings for panel-mounted devices, designed to increase device front protection class to IP65
- The casing does not interfere with pressing of buttons
- Protects from wear-out and erasing of writings
- Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
- Plinth or foundation for fixing the cabinet.
- PLC controller with a display that changes the backlight depending on operating mode.
- Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
- Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.
Fluid level electrode ASTA 460 MM4.
Electrode length
460 mm
Electrode material
Stainless steel (AISI 304)
Thread
M4 More information on electrode extension ASTA 460 MM4 on Lovato website [EN]
..
SF6 gas concentration control base station SF6-Network Monitor. The device manages up to 5 units of SF6-Air sensor. Warning and alarm thresholds can be set for each SF6 Air Sensor.The plug-and-play operating concept makes the handling very comfortable. Measuring values can be stored and called on the 5.7" colored touch screen, if necessary. Technical specifications
Connection:
max. 5 SF6 Air Sensors via bus system
Indication:
colored 14.5 cm (5.7") touch screen
Max. length ..
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications
Sensor:
NDIR, 2
Measuring range:
0 ... 1000 ppm
..
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists.
..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists. &n..
Stainless steel gauge cock, vent hole type. Technical specificationsProcess connection: in case of 3 way gauge cock 1/2 (MxFxF), in case of 2 way gauge cock 1/4, 1/2, 3/8, (FxF), (MxF), (MxM); Operating temperature: up to 180 °C;Max pressure: up to 100 kg/cm²;Housing: stainless steel AISI 316 SS; 05-03 datasheet [EN]
..
- Designed to measure the thickness of non-magnetic layers
- Can be used for construction, ships, tanks, piping, boilers, vehicles protective layer quality control
- High accuracy in wide temperature (with compensation) range using the same probe
- Fit for work outside
- Certificate of calibration included
- The Vape Detector FD-VAPE-WALL operates using the TUYA Smart App
- Connection via WiFi
- Possibility to pair with TUYA camera and create scene to record when vape alarm triggered
- Sensors: PM2.5 Laser Scattering, Temperature and Humidity
- PM2.5 Detection Range: 0-999 µg/m3
- PM2.5 Response Time: 5 seconds
- Temperature Detection Range: 0…60 °C
- Temperature Response Time: 5 seconds
- Humidity Detection Range: 0 - 100% RH
- Humidity Response Time: 5 seconds
- Working Environment: 0…60 °C < 99% RH
- Power Supply: 5V DC USB (micro USB)
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications
Switching power
≤ 10 W
Switching voltage
≤ 200 V
Switching current
≤ 0,5 A
Ambient temperature
-20...90 ºC
Casing material
PP (polypropylene) for water and weak acid devices LV datasheet [LT]
..
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
- Communication: wireless M-BUS
- Mode: S / T
- Measurement accuracy
- Temperature: ± 0,3 °C in the range of -10…55 °C
- Humidity: ± 2 % in the range of 20…80 %
- Transmission interval: 1 / 5 / 10 / 15 min
- AES-128 encryption mode 5 according to OMS V3.0.1
- Supply: 2 replaceable AA cells
- Battery lifetime up to 10 years