- Metal-oxide gas sensor
- Range: 0...100% LEL (0...5 %) CH4
- Resolution: 0,1 % LEL (50 ppm) CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical gas sensor
- Range: 0...250 ppm NO
- Resolution: 1 ppm NO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 3 / 6 ppm NO2
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range:
- -- 0...20 ppm NO2
- -- 0...200 ppm NO2
- Resolution:
- -- 0,1 ppm NO2 for 20 ppm range
- -- 1 ppm NO2 for 200 ppm range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 19,5 / 18 % vol O2
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Electrochemical gas sensor
- Range: 0...25 % O2
- Resolution: 0,01 % O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 12...36 VDC, 24 VAC or 230 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution < 0,1 / 1,5 ppm SO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 2 / 5 ppm SO2
- Attached or remote sensor
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution 0,1 / 1,5 ppm SO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...50 ppm SO2 / 0...2000 ppm SO2
- Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265
- Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
- Switch output: 4 x SPDT (2 for each sensor)
- Alarms: LED indicators and buzzers (85 dB)
- Supply: 24 VDC/VAC / 90...265 VAC
- Protection class: IP65
- For toluene, xylene, ethanol, etc.
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 3 ppm LEL
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 % / 50 % LEL
- Remote probe option
- For toluene, xylene and ethanol
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 relays with switch-over contacts
- Default alarm set-points 10 % / 25 % LEL
- Visual and acoustic alarms
- For toluene, xylene and ethanol
- Default calibration toluene
- Long-life metal-oxide sensor
- Range 0...100 % LEL (0...1 % vol) toluene
- Resolution 3 ppm toluene
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 % / 50 % LEL
- Acoustic alarm
- For toluene, xylene, ethanol, etc.
- Default calibration toluene
- Long-life metal-oxide sensor
- Range 0...100 % LEL
- Resolution 3 ppm toluene
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- For toluene, xylene, ethanol and 2-propanol
- Default calibration toluene
- Stable long-life metal-oxide sensor
- Range: 0...100 % LEL or 0…500 ppm
- Resolution 0,1 % LEL or 1 ppm
- Outputs: 2 relays with switch-over contacts
- Acoustic and visual alarms
- Photo ionization detector
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: isobutylene
- Range: 0...40 / 0...200 ppm (isobutylene)
- Resolution: 1 / 1 ppb
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+65 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: toluene
- Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
- Resolution: 0,1 % LEL / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC