Evikon

Evikon - develops, manufactures and markets sensor-based electronic measurement instruments for industrial and building automation applications.

Evikon brand today is a diverse range of application-oriented devices – sensor assemblies, transmitters with analog and digital outputs, data-loggers, industrial panel meters and controllers – for measurement or control of main process and environment variables:

  • Temperature
  • Pressure
  • Level
  • Humidity
  • Toxic and explosive gases

evikon.eu →

 

Evikon E2200 family humidity transmitters [EN]

Evikon E2600 family gas detectors [EN]

Show:
Sort By:
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2

  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485

  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 19,5 / 18 % vol O2

  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options

  • Electrochemical gas sensor
  • Range: 0...25 % O2
  • Resolution: 0,01 % O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 12...36 VDC, 24 VAC or 230 VAC

  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,3 / 1 ppm O3
  • Attached or remote sensor

  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor

  • Electrochemical gas sensor
  • Range: 0...5 ppm O3
  • Resolution: 0,01 ppm O3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485

  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Long-life MOS sensor
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485

  • MOS gas sensor
  • Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
  • Standard calibration: R-404a
  • Range: 0...1000 ppm HFC
  • Resolution: 1 ppm HFC
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+60 °C
  • Supply: 11..30 VDC / 24 VAC arba 90...265 VAC

  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor

  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor

  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265

  • Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
  • Switch output: 4 x SPDT (2 for each sensor)
  • Alarms: LED indicators and buzzers (85 dB)
  • Supply: 24 VDC/VAC / 90...265 VAC
  • Protection class: IP65

  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm LEL
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Remote probe option

  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 relays with switch-over contacts
  • Default alarm set-points 10 % / 25 % LEL
  • Visual and acoustic alarms

  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL (0...1 % vol) toluene
  • Resolution 3 ppm toluene
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Acoustic alarm

  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm toluene
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option

  • For toluene, xylene, ethanol and 2-propanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range: 0...100 % LEL or 0…500 ppm
  • Resolution 0,1 % LEL or 1 ppm
  • Outputs: 2 relays with switch-over contacts
  • Acoustic and visual alarms

  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC