- Temperature sensor AUREGIS TJ-4 is inextricably connected to the cable. It is designed for temperature measurement from -50°C to 400°C
- Various sizes are available depending on customer requirements and drawings
- Sensor type: PT100, PT1000, K, J, Ni120, Ni1000 and others
- Sensor type: RTD (Pt100, Pt1000), TC (K, J)
- Output: RTD (Pt100, Pt1000), TC (K, J), 4...20 mA, 4...20 mA +HART, 0...10 V, RS-485, IO-LINK
- Measuring range: -30 °C ... 250 °C, 550 °C
- Accuracy: Class A or B /cl.2
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6/8/10mm
- Length: 100, 200, 500, 700, 1000mm or on request
- Connection head type: B
- Protection class: IP65
- Electrical connection: 2-wire, 3-wire or on request
- Process connection: G¼”; M20x1,5; G½” or on request
- Various sizes are available depending on customer requirements and drawings
- Temperature sensor AUREGIS TJ-1 is inextricably connected to the cable
- It is designed for temperature measurement from -50°C to 400°C
- Various sizes are available depending on customer requirements and drawings
- Sensor type: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- The temperature sensor TJ-M is designed for measuring the temperature in the capacity ranging from -30°C to 550°C
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, K, J
- Connection head type: M
- Protection class: IP65
A and B connection threads:
G1/4, G1/2, M20x1,5, M10x1, M12x1,5, M20x1,5, G3/4, M16x1,5, M22x1,5,
Spec, G1/2L*
* - left-hand thread
Material: stainless steel-DIN 1.4301 (AISI 304)
Note: other ordering versions possible.
Solid drilled threaded thermowells, protective cases:
- Protect and extend the lifetime of temperature sensors and thermometers in processing applications
- Facilitate the replacement of sensors
- Allow sensor maintenance without process interruption
- Designed to be weld-in into pipelines and boilers
- Instrument standard threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: solid or welded
- Available materials: 1.4301 (AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Standard instrument threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: welded or solid (flange welded)
- Available materials: 1.4301(AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
Thermowells protect and extend the lifetime of temperature sensors and thermometers in processing applications where the sensors are not mechanically or chemically compatible with the process environment. Moreover, thermowells facilitate the replacement of sensors and allow sensor maintenance without process interruption.
- The purpose of the test chamber is to measure the airtightness of doors which are in the frame of chamber at set pressure
- Air is driven into the chamber with a ventilator which is controlled by an AC drive
- The intake flow rate is measured by CS Instruments VA420 flow rate meter (0-480 m3/4)
- The pressure in chamber is measured with DPT series differential pressure transmitter
- The temperature in chamber is measured in 11 points
- All data is logged and visualized in logger and computer (via IGSS software)
- Electrode level sensor AUREGIS LJ-B for level measurement
- Process temperature: From -30 to 180°C
- Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
- LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
- Process temperature: -20...+80 °C
Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-EB for liquids level measurement. By request sensor can be made with 2 to 5 electrodes with different lengths.
- Electrodes: Stainless steel DIN 1.4301 (AISI 304)
- Insulator: Teflon
- Electrode extension: Stainless steel DIN 1.4301 (AISI 304)
- Process connection: Stainless steel DIN 1.4301 (AISI 304)
- Connection head: Aluminum alloy
- Electrode length: Standard – 1000 mm or by request
- Process connection: R1 1/2“
- Process temperature: -30...+180 °C
Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.
- Material of float: stainless steel AISI 316 SS
- Max. temperature: -30...+105 °C
- Switch rating: 50 VA
- Switching voltage: 230 AC / DC
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
System is designed to measure width of planar products on conveyor belt. System can be used as a separate module or integrated into production line for process control. It enables to compensate conveyor belt unevenness even if shaft imbalance to axle is present, not affecting measurement accuracy.
If there is no way to measure the product from both sides (i.e. on conveyor belt), one-sided system can be used. In this way the accuracy will depend on evenness of product movement.
Can be conducted without stopping the belt:
- Measure product width
- Detect product curvature
Additional functions:
- Count products
- Measure downtime
- Control processes which influence product width
System consists of following:
- Sensor Instruments high accuracy laser distance sensors
- PLC
- HMI or computer
- The system is designed to monitor pressure and flow rate of medical gasses
- Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
- SCADA software enables the visualization of the process
- Data is logged annd represented on the computer screen
- Values can also be represented in graphs
- Temperature sensor AUREGIS TJ-2 with mineral insulation is inextricably connected to the cable
- It is designed for temperature measurement from -50°C to 550°C for RTD sensors Pt100, Pt1000 and from -50°C to 1150°C - for thermocouples
- Various sizes are available depending on customer requirements and drawings
The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.
- Connection connector: M12 (4 / 8 pins)
- Floats and float holders are customizable (on request)
- Connection thread: G3/4" or larger (on request)
- Switching power: 25 VA
- Switching voltage: 24 V AC/DC
- Process part operating temperature: -30...+105 °C
- Process part: Stainless steel AISI316L
- Protection class: IP65
- Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
- Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Multipoint temperature sensor AUREGIS TJ-D is designed for temperature measurement in different levels of measured environment
- Temperature sensors can be put in one casing or in separate casings
- When they are put in separate casings, measurement points can be spread in various places vertically and horizontally
- The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
- The data is gathered from various measuring devices and conveyed into a PLC
- PLC and SCADA interface is MODBUS TCP
- Manual and automatic control is available
- Marameters can be changed via SCADA (IGSS) software
- All data is logged
- Oxygen concentration measuring in air and inert gas mixtures
- Specially developed for use in composting plants
- Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
- Value indicator of measured oxygen concentration
- Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
- Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
- Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
- Material of protective tube: Stainless steel 1.4301
- Housing ambient temperature: -10…+50 °C
- Probe ambient temperature: -10…+100 °C
- Protection class of housing electronic: IP65
- Protection class of probe: IP40
- Rechargeable battery with indication of voltage
- It is possible to connect the sensor to a stationary data processing system
- Temperature indicator TI-N20, TI-N24 for temperature measurement from -30 to +800 °C
- Various temperature sensor construction types are available
- Temperature indicator TI-N20/5, TI-N24/5 for temperature indication
- Various temperature sensor constructions are available: Pt100, Pt1000; NTC, PTC, termopora K, J
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state
- Penetration temperature sensor TJ-ST
- Sensor type: Pt100, Pt1000
- Accuracy: A or B
- Measuring range: -30 °C...+180 °C
- Measuring part diameter: Ø 4 mm
- Measuring part length: 100 mm
- Material: stainless steel
- Various sizes are available depending on customer requirements and drawings
- Temperature sensor AUREGIS TJ-1-TE for temperature measurement from -40°C to 105°C
- Water-resistant – protection class IP68, fully cast in thermoplastic rubber
- Good properties in extreme freezing-melting conditions
- Temperature sensor TJ-B with pipe mounting
- Measuring range: -30 to 180, 250, 400°C
- Sensor type: RTD (Pt100, Pt1000), TC (K, J)
- Accuracy: A or B class / cl. 2
- Output: RTD (Pt100, Pt1000), TC (K, J), 4...20 mA, 4...20 mA +HART, 0...10 V, RS-485, IO-LINK
- Measuring part: Plate by pipe
- Material: Stainless steel AISI304 (1.4301)
- Connection head
- Type: B
- Protection class: IP65
- Extension tube
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø 10 mm
- Length: 10; 50 mm, or according to request
- Straps: 2 pcs., not included
- Probe for process tube: Ø 15 - 40 mm
- Temperature sensor AUREGIS TJ-DIN for temperature measurement
- 35 mm DIN rail mounting
- Measuring range: -50...+70°C
- Temperature sensor AUREGIS TJ-H with hygienic – food process connection and special welded slot, designed for temperature measurement from -50 to +400 °C
- Temperature sensor construction specially designed for usage in food, pharmaceutical, water extraction and water purification, biotechnology and other industries
- Temperature sensor and slot are made of stainless steel
- Measuring range: from -50°C to 250°C, 400 °C
- Temperature sensor AUREGIS TJ-H with hygienic – food process connection and M12x1 4 pin connector
- Sensor type: RTD (Pt100, Pt1000), TC (K, J)
- Accuracy: A or B
- Measuring range: from -50°C to 400°C
- Sensor tube:
- Length: 100, 180, 200 mm
- Diameter: Ø6/8/10 mm
- Material: stainless steel
- Process connection tread: G1/2
- Transmitter output type: 4...20 mA, 4...20 +HART, 0-10 V, RS-485 other parameters acc. to requirement
- Cable connector: M12x1 4 pin
- Various sizes are available depending on customer requirements and drawings
- Sensor type: Pt100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- Measurement range: -30...180 °C
- Cable: 2, 3, 4-wire
- Magnetic mounting ring
TJ-1V sensor is convenient for installation on pipes with staples. For HVAC systems.
- Measurement range: -30...+105 °C
- Sensor type: PT100, PT1000, PTC, NTC, Ni1000, TC K
- Sensor measurement material: brass
- Cable of two or three wires with PVC isolation. Cable length: on request
Temperature sensor AUREGIS TJ-PL6 is integrally connected to the cable. Protection from UV
Purpose: solar panels and other surfaces.
- Sensor type: PT100, PT1000, PTC, NTC, Ni1000
- Sensor working temperature range*: -40...+90 °C
- Cable wires*: 3-wire
- Sensor material: aluminum
- Plate diameter / thick: Ø30 mm / 10 mm
- Cable length: according to order
* - we produce according to individual orders
- Temperature sensor with penetration probe, “T” type handle and cable connection head
- Various sizes are available depending on customer requirements and drawings
- Sensor type: Pt100, Pt1000, K, J
- Accuracy class: A or B / cl. 1 or 2
- Measuring range: -30...180 °C or -30...260 °C on request
- Sensor’s tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø 6 / 8 / 10 mm
- Length: 100, 200, 500, 700, 1000 mm on request
- The total length of the sensor handle is 220 mm
- Connection head:
- Type: M, B (transducer on request)
- Protection class: IP65
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…80 °C
- Operating temperature: -40…80 °C
- The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6 mm
- Length: 25 mm
- Mounting box:
- Material: Polystyrene
- Dimentions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer