  • Input: differential pressure
  • Typical areas of use are chemical industry and process engineering
  • Measurement range: 75 mbar...70 bar
  • Output: 4...20 mA HART
  • Supply: 12...30 VDC
  • Operating temperature: -40…+85 °C
  • Protection class: IP65
  • Process connection: 1/4-18NPT
  • Enables the PC to be connected to HART interface, i.e. to configure a device
  • Active operation: current loop is supplied
  • Passive operation: used in an existing current loop
  • Included HART-Tool software
  • Supply: from USB
  • Galvanic isolation between USB and HART
  • Input: RTD: Pt100 (2-wire) / TC: K
  • Output: relay (NC/NO)
  • Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Input: infrared sensor (850 nm)
  • Output: 4...20 mA current loop with HART interface, 2x PNP or NPN
  • Measurement range: 0...10 kNTU
  • Measurement rate: 10 measurements per second
  • Display, LED indication
  • Operating temperature: -40...+75 °C
  • Protection class: IP65
  • Supply: 24...30 VDC
  • Rated load: 5...500 kg (chosen from list)
  • Output: 2 mV/V
  • Connection: 3 m cable, 4-wire
  • Operating temperature: -35...+65 °C
  • Supply: 10 VDC
  • Protection class: IP67
  • Rated load: 20...10 000 kg (chosen from list)
  • Output: 2 mV/V
  • Connection: 3 / 6 m cable, 4-wire
  • Operating temperature: -35...+65 °C
  • Supply: 10 VDC
  • Protection class: IP66 / IP67
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65
  • Rated load: 1000 / 1500 / 3000 kg
  • Output: 4...20 mA HART / 10 VDC
  • Function: tension / compression / tension and compression
  • Vibration protection
  • Operating temperature: -25...+60 °C
  • Supply: out of current loop / 10 VDC
  • Protection class: IP54
Loading...